– 1 – RAS-S10CYT/RAC-S10CYT RAS-S13CYT/RAC-S13CYT RAS-S10CYT RAS-S13CYT RAC-S10CYT Instruction manual Page 1~22 To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.     23-44                   RAC-S13CYT C S10CYT S13CYT 1 3/27/09 3 41 56 PM – 2 – ! ! SAFETY PRECAUTION ●Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit. ●Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety. ●The sign indicate the following meanings. ●Please keep this manual after reading. WARNING PRECAUTIONS DURING INSTALLATION ●Do not reconstruct the unit. Water leakage, fault, short circuit or fire may occur if you reconstruct the unit by yourself. ●Please ask your sales agent or qualified technician for the installation of your unit. Water leakage, short circuit or fire may occur if you install the unit by yourself. ●Please use earth line. Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone. Improper installation of earth line may cause electric shock. ●A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit breaker, the danger of electric shock exists. ●Do not install near location where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around it. ●Please ensure smooth flow of water when installing the drain hose. CAUTION ! PRECAUTIONS DURING SHIFTING OR MAINTENANCE ●Should abnormal situation arises (like burning smell), please stop operating the unit and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may occur if you continue to operate the unit under abnormal situation. ●Please contact your agent for maintenance. Improper self maintenance may cause electric shock and fire. ●Please contact your agent if you need to remove and reinstall the unit. Electric shock or fire may occur if you remove and reinstall the unit yourself improperly. ●If the supply cord is damaged, it must be replaced by the special cord obtainable at authorized service/parts centers. Make sure to connect earth line. Indicates the instructions that must be followed. The sign in the figure indicates prohibition. W A R N I N G ! ! PRECAUTIONS DURING OPERATION ●Avoid an extended period of direct air flow for your health. W A R N I N G ! ●Do not insert a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at a high speed, it will cause injury. Before cleaning, be sure to stop the operation and turn the breaker OFF. ●During thunder storm, disconnect and turn off the circuit breaker. ●Do not use any conductor as fuse wire, this could cause fatal accident. – 3 – PRECAUTIONS DURING OPERATION ●Do not attempt to operate the unit with wet hands, this could cause fatal accident. ●When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency. ●Do not direct the cool air coming out from the air-conditioner panel to face household heating apparatus as this may affect the working of apparatus such as the electric kettle, oven etc. ●Do not use any aerosol or hair sprays near the indoor unit. This chemical can adhere on heat exchanger fin and blocked the evaporation water flow to drain pan. The water will drop on tangential fan and cause water splashing out from indoor unit. ●Please ensure that outdoor mounting frame is always stable, firm and without defect. If not, the outdoor unit may collapse and cause danger. ●Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit. ●When operating the unit with the door and windows opened, (the room humidity is always above 80%) and with the air deflector facing down or moving automatically for a long period of time, water will condense on the air deflector and drips down occasionally. This will wet your furniture. Therefore, do not operate under such condition for a long time. ●If the amount of heat in the room is above the cooling or heating capability of the unit (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved. ●Do not climb on the outdoor unit or put objects on it. ●Please switch off the unit and turn off the circuit breaker during cleaning, the high-speed fan inside the unit may cause danger. ●Turn off the circuit breaker if the unit is not to be operated for a long period. C A U T I O N ●The product shall be operated under the manufacturer specification and not for any other intended use. ●Do not put water container (like vase) on the indoor unit to avoid water dripping into the unit. Dripping water will damage the insulator inside the unit and causes short-circuit. ●Do not place plants directly under the air flow as it is bad for the plants. ! ●This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely. ●Young children should be supervised to ensure that they do not play with the appliance.

Document Preview & Text Transcription

above 50mm above 100mm about 400mm about 300mm must not bend above 100mm 2,300mm or more 1 2 Maximum pipe length 15m Minimum pipe length 4m above 200mm above 700mm above 200mm above 50mm when installed on the ceiling of balcony ( ) above 100mm above 100mm give clearance as wide as possible Plug 6 4 3 5 HITACHI SPLIT-UNIT AIR CONDITIONER INSTALLATION MANUAL Indoor Unit Outdoor Unit RAS-S13CYT RAC-S13CYT RAS-E13CYT RAC-E13CYT ● + – Screwdriver ● Measuring Tape ● Knife ●Saw ● ø 65mm Power Drill ● Hexagonal Wrench Key ( 4mm) ● Wrench (14, 17, 19, 22, 24, 27mm) ● Gas Leakage Detector ● Pipe Cutter ●Vinyl Tape ● Pliers ● Flare Tool ●Carefully read through the procedures of proper installation before starting installation work. ●The sales agent should inform customers regarding the correct operation of installation. Tools Needed For Installation Work SAFETY PRECAUTION ● Read the safety precautions carefully before operating the unit. ● The contents of this section are vital to ensure safety. Please pay special attention to the following sign. WARNING ........ Incorrect methods of installation may cause death or serious injury. CAUTION ......... Improper installation may result in serious consequence. Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating the unit as described in the user’s guide. ! ! THE CHOICE OF MOUNTING SITE (Please note the following matters and obtain permission from customer before installation). WARNING ! ●The unit should be mounted at stable, non-vibratory location which can provide full support to the unit. WARNING ! ●The outdoor unit must be mounted at a location which can sup- port heavy weight. Otherwise, noise and vibration will increase. CAUTION ! ●No nearby heat source and no obstruction near the air outlet is allowed. ●The clearance distances from top, right and left are specified in figure below. ●The location must be convenient for water drainage and pipe connection with the outdoor unit. ●To avoid interference from noise please place the unit and its remote controller at least 1m from the radio, television and inverter type fluorescent lamp. ●To avoid any error in signal transmission from the remote controller, please put the controller far away from high-frequency machines and high-power wireless systems. ●The installation height of indoor unit must be 2.3m or more. CAUTION ! ●Do not expose the unit under direct sunshine or rain. Besides, ventilation must be good and clear of obstruction. ●The air blown out of the unit should not point directly to animals or plants. ●The clearances of the unit from top, left, right and front are specified in figure below. At least three of the above sides must be open air. ●Be sure that the hot air blown out of the unit and noise do not disturb the neighbourhood. ●Do not install at a location where there is flammable gas, steam, oil and smoke. ●The location must be convenient for water drainage. ●Place the outdoor unit and its connection wire at least 1m away from the antenna or signal line of television, radio or telephone. This is to avoid noise interference. ●Do not install outdoor unit facing strong wind direction. It may damage the fan motor. INDOOR UNIT Names of Indoor Components Qty No. Item The Length of Indoor Unit Connecting Cord Figure showing the Installation of Indoor and Outdoor Unit. about 1.6m about 0.9m OUTDOOR UNIT Drain hose Installation of Hanger, Wall Penetration and Installation of Protection Pipe 1 CAUTION ! ●The draining of the water container inside the indoor unit can be done from the left. Therefore the hanger must be fixed horizontally or slightly tilted towards the side of drain hose. Otherwise, condensed water may overflow the water container. Direct Mounting On The Wall ●Please use hidden beams in the wall to hold the hanger. Wall Penetration and Installation of Protection Pipe ●Drill a ø 65mm hole on wall which is slightly tilted towards the outdoor side. Drill the wall at a small angle. ●Cut the protection pipe according to the wall thickness. ●Empty gap in the sleeve of protection pipe should be completely sealed with putty to avoid dripping of rain water into the room. Procedures of Installation and Precautions ●Procedures to fix the hanger. 1.Drill holes on wall. 2. Push plug into the holes. 3. Fix the hanger on wall (As shown below) (As shown below) with 4.1 x 32 screw (As shown in figure below) ●Procedures to fix the holder of remote controller. 1.Drill holes on wall. 2. Push plug into the holes. (As shown below) (As shown below) Installation of the Indoor Unit 2 VERTICALLY DOWNWARD PIPING Preparation ●Connect connecting cord. ●Pull out the pipe, connecting cord and drain hose. Installation ●The upper part of the indoor unit is hanged on the hanger. ●The projection at the lower part of the indoor unit is hooked onto the hanger. Please pull the lower part of the indoor unit outwards to check if the unit is hooked onto the hanger. Improper installation may cause vibration and noise. ! CAUTION HORIZONTAL PIPING Preparation Change of Drain Hose and Installation Procedures. ●Exchange the location of drain hose and drain cap during horizontal piping as shown in figure below. Be sure to plug in the drain hose until the insulating material folds upon itself. ●Please use pliers to pull out the drain cap. (This is an easier way to remove the drain cap). Drain hose Drain cap Drain cap ●Remove the cap for drain hose installation Drain cap Please insert until here Drain hose Please insert until here ! CAUTION Condensed water may leak out if not inserted properly. HORIZONTAL & DOWNWARD PIPING – MAKING OPENINGS ●During horizontal or downward piping, use a knife to cut openings as shown in figure. Then smoothen the edges of openings with a file. INSTALLATION OF REFRIGERATING PIPES AFTER CONNECTION ●The refrigerating pipes should be adjusted to fit into the hole on the wall and then ready for further connection. ●The terminals of 2 connected pipes must be covered with insulator used for terminal connection. Then the pipes are wrapped with insulation pipe. ●Connect the connecting cord. ●After adjustment, fit the connecting cord and pipes into the space available under the indoor unit. ! CAUTION ●The rubber strap used for fixing the insulator should not be tied with great force. Otherwise, this will damage heat insulation and causes water condensation. Pipe Rubber strap tied with great force Insulation pipe (must be wrapped with vinyl tape at every 120mm). THE CONNECTION OF REFRIGERATING PIPE DURING THE INSTALLATION OF INDOOR UNIT Preparation To Install Refrigerating Pipes ! CAUTION ●Please fix in the plastic core after flaring to avoid plastic chips entering the pipes. below 5mm Please bend at a small radius to form an arc CAUTION ! You are free to choose the side (left or right) for the installation of drain hose. Please ensure the smooth flow of condensed water of the indoor unit during installation. (Carelessness may result in water leakage.) ! CAUTION Be sure that the drain hose is not loosely connected or bent. Be sure that the wire is not in contact with any metal in the wall. Please use the protection pipe as wire passing through the hollow part of the wall so as to prevent the possibility of damaged by mouse. ! CAUTION ●Refrigerating pipes and connecting cord must be tied together. ●The front part of the refrigerating pipes are at locations marked with “ ” symbol. Installation of Drain Hose 3 Installation Hang the indoor unit onto the hanger. Use the temporary stand at the back of the indoor unit to push its lower part 15cm forwards. ●Place the drain hose through the hole on the wall. ●Insulate the connecting portion of refrigerating pipe with insulator. ●Wrap the refrigerating pipes with insulation pipe. ●Connect the connecting cord. ●After adjustment, the connecting cord and refrigerating pipes are placed into the space available under the cooling unit. ●The projection of indoor unit must hook to the hanger. 2~5mm Protection pipe Outdoor Indoor Seal with putty Sleeve of protection pipe WALL INDOOR UNIT about 15cm Projection Temporary stand Hook Openings FOR SERVICE PERSONNEL ONLY ●The difference in height between the indoor and outdoor unit should be kept below 5m. ●The connecting pipe, no matter big or small, should all be insulated with insulation pipe and then wrapped with vinyl tape. (The insulator will deteriorate if it is not wrapped with tape). The connection of insulated drain hose. Please use insulated drain hose for the indoor piping (commercial product). inner diameter ø 16mm Be sure to completely seal any gap with putty. Direction of Piping Dimension of Mounting Stand of the outdoor unit (unit : mm) 32mm 19mm Wall 1 Hanger 2 Screw Plug Wall above 50mm Ceiling 4.1 x 32 Screw Wall Remote Control Holder 5 Screw Plug 3 Connecting cords, pipe and drain hose must be tied together with Vinyl tape. Hanger Hook Refrigerating Pipe Connecting Cord Drain Hose Protection Pipe Lift the body of the unit upwards and then force it downwards. Hanger Projection Pipe Connecting cord Drain hose Pipe Insulation pipe 0.70m Bending upwards Condensed water pond Ditch Condensed water pond 20 Cut away shaded portion, and finish the edge of the opening so that there is no burr. Connected section Connecting cord Drain hose Protection pipe Refrigerating pipes Connecting cord Heat insulation pipe Pull this to the front during the connection of refrigerating pipes to ease task. Pipe support Pull up the pipe after bending downward ●Transform the piping while holding down the lower portion of pipe-support by hand. Hanger 1 Screw for holder of Remote Controller (3.1x16) AAA Size Battery Screw for Hanger Holder for Remote Controller (4.1x32) Remote Controller 6 1 2 2 1 57 12 35 120 500 320 10 35 (10) 340 mounting stand 1 2 3 4 5 6 WARNING ! CAUTION ! ● A circuit breaker or fuse (20A time delay) must be installed. Without a circuit breaker or fuse the danger of electric shock exists. A main switch with a contact gap of more than 3mm has to be installed in the power supply line to the outdoor unit. ● Do not install the unit near a location where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around it. ● Please ensure smooth flow of water when installing the drain hose. ● Piping shall be suitable supported with a maximum spacing of 1m between the supports. ● Please request your sales agent or qualified technician to install your unit. Water leakage, short circuit or fire may occur if you do the installation work yourself. ● Please observe the instructions stated in the installation manual during the process of installation. Improper installation may cause water leakage, electric shock and fire. ● Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the units may collapse and impose danger. ● Observe the rules and regulations of the electrical installation and the methods described in the installation manual when dealing with the electrical work. Use power cables approved by the authorities of your country. ● Be sure to use the specified wire for connecting the indoor and outdoor units. Please ensure that the connections are tight after the conductors of the wire are inserted into the terminals. Improper insertion and loose contact may cause over-heating and fire. ● Please use the specified components for installation work. Otherwise, the units may collapse or water leakage, electric shock and fire may occur. ● Be sure to use the specified piping set for R22. Otherwise, this may result in broken copper pipes or faults. ● When installing or removing an air conditioner, do not allow air or moisture to remain in the refrigeration cycle. Otherwise, pressure in the refrigeration cycle may become abnormally high so that a rupture may be caused. ● Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with fire, a poisonous gas may occur. ● After completion of installation work, check to make sure that there is no refrigeration gas leakage. If the refrigerant gas leaks into the room, coming into contact with fire in the fan-driven heater, space heater, etc., a poisonous gas may occur. ● Unauthorized modifications to the air conditioner may be dangerous. If a breakdown occurs please call a qualified air conditioner technician or electrician. Improper repairs may result in water leakage, electric shock and fire, etc. Purifying Filter 2 7 Connection Horizontally perpendicular to the unit There are 6 directions allowed, namely, horizontally perpendicular to the unit, vertically down from right, horizontally out from right, horizontally out to left, horizontally out to right, vertically down from left. Don’t form the piping downward at the left of the unit. In case the pipe length is more than 8m, add refrigerant R22 at 20 gram per every meter exceeds. However, pipe length shall not exceed 15m. CAUTION ! The indoor piping should be insulated with the enclosed insulation pipe. (If the insulator is insufficient, please use commersial products). 125mm 45mm 450mm 60mm 80mm 780mm 125mm 280mm 45mm 115mm 450mm Level Hanger Hole for pipe Weight Mark Line Please use more than 4 screws. Screw for Hanger OUTDOOR UNIT ●Please mount the outdoor unit on stable ground to prevent vibration and increase of noise level. ●Decide the location for piping after sorting out the different types of pipe available. ●Open the side plate by unscrewing the screws as shown below. Removal Of Air From The Pipe And Gas Leakage Inspection Gas Leakage Inspection Please use gas leakage detector to check if leakage occurs at the connection of Flare nut as shown on the right. If gas leakage occurs, further tighten the connection to stop leakage. FINAL STAGE OF INSTALLATION Insulation And Maintenance Of Pipe Connection 1 ●The connected terminals should be completed sealed with heat insulator and then tied up with rubber strap. ●Please tie the pipe and power line together with vinyl tape as shown in the figure showing the installation of indoor and outdoor units. Then fix their position with holders. ●To enchance the heat insulation and to prevent water condensation, please cover the outdoor part of the drain hose and pipe with insulation pipe. ●Completely seal any gap with putty. Installation Of Remote Controller 2 Power Source And Operation Test 3 ●The remote controller can be placed in its holder which is fixed on wall or beam. ●To operate the remote controller at its holder, please ensure that the unit can receive signal transmitted from the controller at the place where the holder is to be fixed. The unit will beep when signal is received from the remote controller. The signal transmission is weaken by the florescent light. Therefore, during the installation of the remote control holder, please switch on the light, even during day time, to determine the mounting location of the holder. Power Source CAUTION ! ●Please use a new socket. Accident may occur due to the use of old socket because of poor contact. ●Please plug in and then remove the plug for 2 – 3 times. This is to ensure that the plug is completely plugged into the socket. ●Keep additional length for the power cord and do not render the plug under external force as this may cause poor contact. ●Do not fix the power cord with U-shape nail. Operation Test ●Please ensure that the air conditioner is in normal operating condition during the operation test. ●Explain to your customer the proper operation procedures as described in the user’s manual. Insulation material for pipe connection Sleeve of protection pipe Putty 3 Preparation of Pipe 1 ●Use a pipe cutter to cut the copper pipe. ●Jagged edge will cause leakage. ●Point the side to be trimmed downwards during trimming to prevent copper chips from entering the pipe. ●Before flaring, please put on the flare nut. Pipe Connection 2 INSTALLATION OF REFRIGERATING PIPES AND AIR REMOVAL CAUTION ! Outer diameter of pipe 6.35 (1/4") 12.7 (1/2") Valve head cap Valve core cap Torque N.m (kgf ● cm) 13.7 – 18.6 (140 – 190) 44.1 – 53.8 (450 – 550) 19.6 – 24.5 (200 – 250) 12.3 – 15.7 (125 – 160) Copper pipe Trimming tool Outer Diameter (ø) 6.35 (1/4") 12.7 (1/2") Imperial flaring tool 0.8 – 1.5 1.0 – 2.0 Rigid flaring tool 0 – 0.5 0 – 1.0 A (mm) Small diameter side Big diameter side AIR REMOVAL WARNING ●You may not be able to close the side cover due to the connecting cord, under such situation, please press against the wall of side cover to fix it. ●Be sure that the hooks (2 places) are plugged in. Otherwise, water leakage may occur and this causes short circuit or faults. Checking for the electric source and the voltage range ●Before installation, the power source must be checked and necessary wiring work must be completed. To make the proper wiring capacity, use the wire gauges list below for the lead-in from a pole transformer and for the wiring from a switch board of fuse box to the outlet in consideration of the locked rotor current. ●Investigate the power supply capacity and other electrical conditions at the installation location. Depending on the model of room air conditioner to be installed, request the customer to make arrangements for the necessary electrical work etc. The electrical work includes the wiring work up the outlet. In localities where electrical conditions are poor, use of a voltage regulation is recommended. Wire length up to 16m up to 10m up to 15m up to 25m up to 42m Wire gauge 1.6mm (B.S. 14) 2.0mm (B.S. 12) 2.6mm (B.S. 10) 3.2mm (B.S. 18) 14mm2 (B.S. 16) IMPORTANT ●THIS APPLIANCE MUST BE EARTHED. Procedures of Wiring ●Connect the electrical wiring between the indoor and outdoor unit as shown in below Fig. Never connect the wiring by mistake. ●The connection cord must be fixed by the band which is located on the electrical box. Wiring Of The Outdoor Unit ●Please remove the side cover for wire connection. ! WARNING ! CONNECTION OF POWER CORD A Die Die Copper pipe Wrench Torque wrench Flare nut The body of service valve Cap of valve core Hexagonal Wrench Key Cap of valve head Cap of valve head CAUTION ! In case of removing Flare nut of a cooling unit, first remove a nut of small diameter side, or else seal cap of big diameter side will fly out. ●Please be careful when bending the copper pipe. ●Applied frozen grease to the connection points and then screw in manually. After that, use a torque wrench to tighten the connection. WARNING ! Power supply shall be connected at the rated voltage, otherwise the unit will be broken or could not reach the specified capacity. Detail of cutting the connecting cord To remove the connecting wires for the indoor unit, please remove the low cover panel in front of the unit. A B A B (L) Brown (N) Blue Terminal Board Line Cord Terminal Board Green & Yellow Green & Yellow Outdoor Unit Indoor Unit Indoor Unit Outdoor Unit GRN + YEL 10mm 30mm 30mm 10mm GRN + YEL 70mm 35mm 10mm Please face this side (suction side) of the unit to the wall. Please remove side cover when connecting the piping and connecting cord. Pull downward Connect the earth cord After remove the screw and band, put the connecting cords and fix the band with screw. Earth terminal B A A B Wiring Of The Indoor Unit ●For wire connection of the Indoor unit, you need to remove front panel and electrical cover. Method to remove front panel ●Refer to “How to Remove The Front Cover”. CAUTION ! Please make sure to remove all spacers inside the unit. ●Open the Top, Back and Side cover of the unit. ●Pull out the spacers inside. (Spacers are only for transportation purpose). If not remove, vibration and noise will occur. Top cover Back cover Side cover The controller should be insert from top into bottom side of the holder as shown in figure below. ●The naked part of the wire core should be 10 mm and fix it to the terminal tightly. Then try to pull the individual wire to check if the contact is tight. Improper insertion may burn the terminal. ●Be sure to use only power cables approved from the authorities in your country. For example in Germany: Cable type: NYM 3x1.5mm2, (fuse = 20A time delay) ●Please refer to the installation manual for wire connection to the terminals of the units. The cabling must meet the standards of electrical installation. ●There is a AC voltage of 220V between the L and N terminals. Therefore, before servicing, be sure to remove the plug from the AC outlet or switch off the main switch. When the meter reaches - 101KPa (-76cmHg) during pumping, fully tighten the shuttle. Meter showing pressure Closed Manifold valve Vacuum pump Valve Charge hose Valve Vacuum pump adapter When pumping starts, slightly loosen the flare nut to check of air sucked in. Then tighten the flare nut. Lo Hi Procedures of using Vacuum Pump for Air Removal As shown in right figure, remove the cap of valve core. Then, connect the charge hose. Remove the cap of valve head. Connect the vacuum pump adapter to the vacuum pump and connect the charge hose to the adapter. Fully tighten the “Hi” shuttle of the manifold valve and completely unscrew the “Lo” shuttle. Run the vacuum pump for about 10–15 minutes, then completely tighten the “Lo” shuttle and switch off the vacuum pump. Completely unscrew the spindle of the service valve (at 2 places) in anti- clockwise direction to allow the flow of coolant (using Hexagonal Wrench key). Remove the charge hose and tighten the cap of valve head. Check the cap’s periphery if there is any gas leakage. The task is then completed. 2 3 4 1 Method to remove the low cover ●Pull the cover at 1 and 2 in the directions as shown by arrows to remove the cover. Remote Controller Holder for Remote Controller Screw (2 pieces) How to Remove The Front Cover 1 Remove the front panel. ● Please remove and attach the front panel by both hands. ● After opening the front panel by both hands. 1 1 1 1 1 Undo the right arm while pushing it inside. 2 2 2 2 2 Slide the front panel to right as shown in figure. Then remove while pulling it to front. 2 Remove the filters. 3 After removing two screws, pull the center of the front cover towards you and release the claws. 4 Pull the side faces (lower sections) of the front cover towards you as shown in the figure and remove the cover. How to Attach the Front Cover 1 Check that the drain pan is securely attached. 2 After installing the front cover onto the unit, hook three claws at upper side of the cover securely. Then, push the center of the front cover to lock the claws. 3 Tighten the two screws. 4 Install the filter. 5 Slide the shafts of the right and left arms on the washable panel along the steps to insert the shafts into the holes till they stop. After checking that the shafts are securely inserted, close the panel. Step Shaft Hole ! CAUTION Note: ●Outdoor supply cords shall not be lighter than polychloroprene sheathed flexible cord, 60245 IEC 57. IMPORTANT 20A time delay fuse Fuse Capacity