Honeywell 5815 - Ademco - Wireless Door Manuals

1 pdf manual(s) Honeywell 5815 - Ademco - Wireless Door for free download (Document Types: Installation instructions)

Honeywell 5815 - Ademco - Wireless Door Installation instructions [PDF] (2 pages)

  • Identifier: id-460116
  • Brand: Honeywell
  • Device: 5815 - Ademco - Wireless Door Other
  • Type: PDF
  • Key Aspects: Warranty and Service Information, Manufacturer Contact and Support Data, System Connectivity and Wiring Basics
  • UPD Date: 26.08.2026
  • Source File: 443619.pdf
  • Pages: 2
  • Description: Device user manual for the Honeywell 5815 - Ademco - Wireless Door.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
K5503V2 4/08 Rev. A ADEMCO 5815 DOOR/WINDOW TRANSMITTER INSTALLATION INSTRUCTIONS 5815-01-V0 LOCKING TAB RELEASE WINDOW COVER PRY-OFF SLOT MOUNTING PLATE HOLES (2) OBSERVE POLARITY LOCKING TAB WIRES MOUNTING PLATE CASE COVER RETAINING HOOKS (3) POST (2) WIRE BREAKOUT (2) Figure 1. Mounting Plate and Case GENERAL INFORMATION The Honeywell Ademco 5815 is a two-zone Door/Window Transmitter that has its own unique serial number. The control unit is required to "enroll" the serial number prior to its usage in the alarm system. Refer to the control unit's installation instructions for further details. Note: During programming of the control unit, 5815 transmitters should be treated as "RF" (i.e., supervised RF) Type (mandatory for UL installations). The 5815 provides two input loops (zones): the first for a wired closed-circuit contact loop, and the second for its built-in reed switch (used in conjunction with a magnet, as described below). One or both inputs may be used. For UL installations, a contact may not be more than 3 feet from the transmitter. The 5815 includes a built-in cover tamper, which is activated when the cover is removed. MOUNTING For proper orientation of the unit in relation to the mounting plate, loop wiring, and/or magnet, read all of this section before installing the unit. The description that follows assumes that the unit will be mounted as shown in the diagrams, with the magnet (if used) located in one of the positions shown in Figure 2. The unit may, however, be installed in any direction, as long as the relationship of the unit to its mounting plate and (if used) magnet is maintained. Although the unit can be mounted directly to a surface, we recommend that the mounting plate be used, for ease in removing the unit for servicing should it become necessary. Before mounting the transmitter permanently, conduct Go/No Go tests (see control's instructions) to verify adequate signal strength and reorient or relocate the transmitter if necessary. 1. Remove the transmitter's top cover by inserting the flat blade of a small screwdriver into the pry-off slot at one end of the unit (see Fig. 1 for location), and slightly twisting the blade until the cover disengages. IMPORTANT: DO NOT REMOVE the circuit board from the back case plastic. 5815-002-V0 LOOP TERMINALS (LOOP 1) LITHIUM BATTERY CR1-335 (3V) COVER RETAINING HOOKS (3) ANNTENNA + + COVER PRY-OFF SLOT WIRE ENTRY HOLE TAMPER SWITCH IC CRYSTAL REED SWITCH (LOOP 2) REED SWITCH (LOOP 2) (ALTERNATE POSITION FOR MAGNET)* *MAGNET (OBTAIN SEPARATELY) + _ * MAGNET MUST BE WITHIN 1/2" OF REED SWITCH Figure 2. 5815 (shown without cover) 2. Disengage the attached mounting plate from the case by inserting the blade of a small screwdriver into the locking tab release window (see Figure 1) and pressing it against the locking tab (also shown in Figure 1), while sliding the mounting plate upward along the case back until free. 3. Install the mounting plate, with its two case- holding posts pointing up (in this example), in the location selected as described in the control panel's installation instructions. Use the flat-head screws supplied. Note: If a wired contact loop is to be used, with concealed wiring, the wire exit hole in the wall must be located under the wire entry hole in the case as shown in Figure 2, and no more than 1/4" in diameter. 4. If a wired contact loop is to be used, feed concealed wiring through the slot in the case back, but do not connect to the terminal block yet. For surface wiring entry, two thin "breakout" areas are provided in the case wall (see Figure 1). 5. Attach the case back to the mounting plate by sliding the keyhole slots in the case back down onto the mounting plate's case holding posts. The locking tab will click as the case back locks in place. 6. If a reed switch is to be used, mount a No. 5899 Magnet (obtained separately) adjacent to the reed switch, or adjacent to the top of the case (see Figure 2). In either case, the magnet must be mounted within one-half inch of the reed switch. LOOP WIRING CONNECTIONS (If used) With the battery still not inserted, connect the contact loop wires to the unit's loop terminals (see Figure 2). Caution: Make sure that the bared sections of the loop wires do not short to the reed switch or antenna. The contact loop must use closed-circuit devices. The loop response time is a nominal 100mSec. NOTE: If the contact loop is not to be used, no connection is needed across the loop terminals.

Honeywell 5815 - Ademco - Wireless Door: Other Category Related Instructions

CITORI OVER UNDER SHOTGUN
Browning CITORI OVER UNDER SHOTGUN
20.07.2026 14 pages

Instruction guidebook for the Browning CITORI OVER UNDER SHOTGUN Other. This manual explains basic operation, firmware updates, device safety checks.

EM 3966
SEVERIN EM 3966
21.08.2026 1 pages

Article Electric Knife Article-Nr. EM 3966 / white-grey EAN-No. 4008146396601 Dimensions 475 mm (W) 107 mm (H) 70 mm (D) Description • 100 W • safety on/off switch • finger protection • release button for blades • dishwasher safe blades • additiona Operation and maintenance manual for the SEVERIN EM 3966 Other. The document covers error codes, error handling, component replacement.

ST-GT550
Technics ST-GT550
16.06.2026 20 pages

Complete user documentation for the Technics ST-GT550 Other. This guide explains the features and error codes, user instructions, technical specifications.

SBC-1
FUTABA SBC-1
14.07.2026 1 pages

nCAUTION j Connect the servo and battery connector in the correct polarity. Connecting the power + and - polarities in reverse by mistake may cause smoke, fire, and damage. l Do not connect a device other than an S.BUS servo or S.BUS decoder to the S.BUS User reference guide for the FUTABA SBC-1 Other. The manual details device operation tips, energy usage, user preferences.