Honeywell LYNXDM-GSM Manuals

1 pdf manual(s) Honeywell LYNXDM-GSM for free download (Document Types: Installation and setup manual)

Document Preview & Text Transcription

K14515V1 8/07 Rev. A LYNXDM-GSM/LYNXDM-IGSM COMMUNICATIONS MODULES INSTALLATION AND SETUP GUIDE SYSTEM OVERVIEW Introduction The LYNXDM-GSM and LYNXDM-IGSM are desk or wall mounted communications modules for the LYNXR-I Series control panel. Each module is equipped with an integral AlarmNet 7845GSM Digital Cellular or 7845- iGSM Internet Communication Module with Remote Services. It represents the latest and most innovative communication technology for the security industry and uses the most sophisticated encryption to ensure the highest level of security for your customer. The LYNXDM-GSM and LYNXDM-IGSM modules require an AlarmNet–i account. For new installations, please obtain the account information from the central station prior to programming this module. General Information LYNXDM-GSM Honeywell's LYNXDM-GSM cellular communication module transmits signals via the AlarmNet-G network (GSM cellular network), using GPRS and forwards them to your Central Station. If the GPRS network is unavailable, the LYNXDM-GSM (if enabled by the dealer) will attempt to send the transmission via SMS (Short Message Service and/or e-mail). LYNXDM-IGSM Honeywell’s LYNXDM-IGSM Internet communication module communicates from your customer’s network connection to the Honeywell NOC via the AlarmNet-I network. The NOC receives data and routes the information to the Central Station of your choice, based on the account number you assign to the module. The same account number is used for both Internet and GSM transmissions. If, for some reason, Internet connectivity is not available (for example, your customer’s ISP is off line or disconnected), the LYNXDM-IGSM will transmit signals via the AlarmNet-G (GSM) cellular network, using GPRS. These transmissions are sent to the Honeywell NOC and then forwarded to your Central Station exactly the same way as if they were received via the Internet. If the Internet AND GPRS are both unavailable, the LYNXDM-IGSM will attempt to send the transmission via SMS, also known as a text message. If all three methods fail, the module will attempt to deliver the alarm until the alarm time expires. Once the old alarm time has expired, the alarm is dead and will not be delivered. About AlarmNet-I Internet Application AlarmNet-I is a fully encrypted, secure method of delivering alarm messages from a protected premise to an AlarmNet equipped central station. An Internet Communicator Module transmits status, supervisory, and alarm messages to the AlarmNet Control Center using a broadband Internet connection. The AlarmNet Control Center identifies, validates, and forwards the messages to the appropriate AlarmNet central station. Encryption The LYNXDM-IGSM supports private key encryption. Private key encryption means that both the sender and the receiver know the KEY used to encrypt the data. Each device produced by Honeywell is loaded with a globally unique identifier called a MAC number, and a large random number or KEY. This KEY and MAC number are also stored in the AlarmNet servers. When a device contacts AlarmNet, it sends the MAC number in the clear followed by the message that is encrypted using the KEY data. The server looks up its copy of the KEY based on the MAC number and uses that KEY to decrypt the message. The LYNXDM-IGSM uses 256 bit AES (Rijndael) encryption (which is required for certain government installations). The AlarmNet-I AES Encryption Software Module Version 1.0 contained in the Honeywell products has NIST approval. Listings for this approval can be found at http://csrc.nist.gov/cryptval/aes/aesval.html Certification number 127. - 2 - System Features Feature LYNXDM-GSM LYNXDM-IGSM • Quick connection to compatible LYNXR-I series control panels x x • Simple programming using a 7720P programming tool x x • Reports fire, burglary, and status messages via wireless network x x* • Reports fire, burglary, and status messages via internet x • Allows uploading and downloading of control panel data via the wireless network. X x* • Allows uploading and downloading of control panel data via internet. X • Provides 2-way communication with the control using ECP messaging x x • Sends reports in Contact ID format x x • Supports two hardwire zone trigger inputs (zones 6 and 7) x x • Easy CAT-5 10 BaseT connection to a hub or router x • Installs behind firewalls without compromising network security x • Supports dynamic or static IP addressing x • Supports remote control of alarm system via Remote Services Feature x x * As a backup to the internet. The LYNXDM-GSM and LYNXDM-IGSM provide the following types of supervision and module fault detection: • Network communication failure: In the event the AlarmNet network does not hear a supervisory message from the module within a specified time (“Supervision” option, 24 hours, 30 days, or none), AlarmNet notifies the central station of a communication failure. • Communication path failure: In the event the module detects a communication path failure, the control panel can be notified of a trouble condition with the module after a specified time has elapsed. Remote Services Features The Remote Services Features can only be used with LYNXR-I Series controls Revision 16 or later. Multi Mode (E-mail notification) is intended as a convenience for the user, and does not replace Central Station reporting of critical events (alarms, troubles, etc.). Remote Services allow the end user to communicate with their Security System remotely via several features. Availability of this service is controlled by the dealer via the web-based programming tool on the AlarmNet Direct website. Once enabled, the specific programming fields associated with these features can be programmed either remotely using the AlarmNet Direct website or locally using the 7720P Programming Tool. These new web services will allow users to: • Receive e-mail and text message notification of system events (Multi-Mode feature) • Access their security system from a computer via a website (Remote Access feature) • Perform system functions and receive confirmations using text messages (SMS feature) INSTALLATION The incoming wiring can be routed through the opening in the rear of the back plate or through the wire troughs in the mount’s case back. A wire knockout is also provided in the desk mount front case. Installing the desk mount 1. Route the incoming power, telephone and/or internet wiring through the appropriate openings in the mount’s rear case. 2. Route incoming power, telephone and communications, etc. wiring through the mount’s front case. 3. Proceed to Wiring the LYNXR-I or LYNXR-ISIA section. Installing the wall mount 1. Locate the rear case over the mounting surface such that the opening in the case is aligned with the wire/cable access opening (in the mounting surface). If the wiring will be run externally, it should be routed through the wire troughs in the wall mount case back. - 3 - 2. Route the incoming power, telephone and/or internet wiring through the appropriate openings in the mount’s rear case. 3. Mount the rear case to a sturdy wall using the four screws (supplied). 4. Route incoming power, telephone and communications, etc. wiring through the mount’s front case. 5. Proceed to Wiring the LYNXR-I or LYNXR-ISIA section. MOUNT (REAR CASE) 09004-005-V0 FOR EXTERNAL ANTENNA 50 OHM, MMCX ONLY Honeywell GSM GPPS WEB MODE 2 MODE 1 RSSI 7720P PROGRAMMER PORT NOT FOR TELEPHONE SERVICE USE! PRIMARY POWER: 9 - 16.5 VAC CURRENT: 900mA PEAK, 70mA STANDBY BATTERY: 8V. 3.1 AHr FOR 24 Hr BACKUP FCC:XXXXXXXXXX IC: YYYYYYYYYY OR ARMED READY RECORD VOLUME PLAY LIGHTS ON TEST BYPASS LIGHTS OFF CODE CHIME STATUS NO DELAY FUNCTION ESCAPE DELETE ADD SELECT AUX 0 # 7 8 9 STAY 1 2 3 4 5 6 OFF AWAY DESK MOUNT (FRONT CASE) WALL MOUNT (FRONT CASE) LYNXR-I / LYNXR-ISIA Figure 1 - LYNXDM-GSM/LYNXDM-IGSM Desk/Wall Mount Installation Wiring the LYNXR-I or LYNXR-ISIA 1. Release the LYNXR-I front case assembly from the rear case by depressing the two locking tabs at the top of the unit with the blade of a medium size screwdriver (refer to Figure 2). 2. Once these tabs have been released, insert the screwdriver in the side of the case and release the side locking tabs by gently twisting. ! DO NOT disconnect the ribbon cable from the terminal strip board. Disconnect the cable only from the front assembly board. 3. Carefully disconnect the ribbon cable from the front assembly, leaving the ribbon cable connected to the terminal block PC board (refer to Figure 2). The rear case contains the terminal block for making wiring connections. When installing the 4-wire communication cable, you may find it easier to make the connection at the LYNXR-I first. The cable can then be routed through the mount’s front case. 4. Feed the 4-wire communication cable from the LYNXR-I rear case through the mount’s front case. 5. Feed the incoming wiring from the wall or desk mount rear case through the mount’s front case and into the LYNXR-I rear case. 6. Slide the LYNXR-I onto the wall or desk mount front case locking tabs. Step 7 only applies to wall mount installations. 7. Once the wires have been routed, the assembled wall mount front case and LYNXR-I rear case can be hung from the wall mount rear case using three hooks on the inside of the wall mount front case and three tabs on lower part of the wall mount’s rear case (refer to Figure 3).