Hoover SteamVac F6056-900 Manuals

1 pdf manual(s) Hoover SteamVac F6056-900 for free download (Document Types: Owner's manual)

Hoover SteamVac F6056-900 Owner's manual Main Page Preview

Owner's manual [PDF] (16 pages)

  • Updated: 04.08.2026

Document Preview & Text Transcription

I® SpinScrubTMwith MAX Extract TM The Easy to Use Deep Cleaner Congratulations on your purchase SteamVac MSpinScrub_cleaners have 6 rotating brushes that deep clean carpets and scrub bare floor!! SteamVac TM SpinScrub TM Deep Cleaner cleans carpet fibers by applyimg hot tap water amd cleamimg solution. www. hoover, co m Fill in and Retain This HOOVER deep cleaner is designed for deep cleaning carpet, rugs, carpeted stairs and upholstery. The model and serial numbers are located on the data label on the back of the handle. For your personal records, please enter the COMPLETE model and serial numbers in the spaces provided and retain this information. Your deep cleaner is model and has serial number It is suggested that you attach your sales receipt to this owner s manual. Verification of date of purchase may be required for warranty service of your Hoover product. Index Important safeguards .......... 2 Assembly ................... 4-5 Carton contents .............. 3 How to use.................. 6-9 Agitator speed selector ....... 7 Automatic "shut-off". ......... 7 Deep cleaner description ...... 6 Emptying the recovery tank .. 8-9 Filling the clean solution tank. 7-8 How to clean After cleaning ............ 9-10 Before you begin ............ 9 Carpet cleaning ............. 10 Cleaning bare floors ......... 11 Clean Surge TMFeature ........ 10 MAX ExtractTMFeature ......... 7 Picking up spills ............ 10 Using the tools .......... 11-13 Attaching tools ............ 11 Cleaning carpeted stairs ..... 12 Cleaning upholstery ....... 13 Scrub module ............ 11-12 Maintenance Headlight replacement ..... 13-14 If you have a problem ........ 15 Lubrication ................ 14 Service ................... 15 Storage ................... 14 Warranty .................... 15 (_P2001 The Hoover Company www.hoover.com 2 ! Owner s Manual ENGLISH ,e pp. 1-15 ESPANOL ,e p_g. 17-26 FRAN(_AIS ,e p. 27-35 Review this manual before operating deep cleaner Important Safeguards! When using an electrical appliance, always follow basic precaution, including the following: READ ALL INSTRUCTIONS BEFORE USING APPLI- RNING' To reduce the risk of fire, electric , shock, or injury: Use indoors only. Use only on surfaces moistened by the cleaning process or small spills. Do not immerse product. Connect to a properly grounded outlet only. See "Grounding Instructions". Do not clean over floor electrical outlets. Do not use without tanks in place. Use extra care when cleaning on stairs. Do not place deep cleaner on stairs. Use deep cleaner only for its intended use as described in the instructions. Use only attachments recommended by The Hoover Company; others may cause hazards. The use of an extension cord is not recommended. If an extension cord is absolutely necessary, use at least a 16 gauge 3-wire cord which has a 3-prong grounding type plug and a 3-pole receptacle that accepts the machine plug. Unplug deep cleaner when not in use. Turn off all controls before unplugging. Unplug before connecting the powered hand tool. Always disconnect cord from electrical outlet before servicing the deep cleaner. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord. Never handle plug or appliance with wet hands. Do not pull or carry by cord, use cord as a handle, close door on cord or pull cord around sharp edges or corners. Do not run appliance over cord. Keep cord away from heated surfaces. Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, take it to a Hoover Factory Service Center or Authorized HooverWarranty Service Dealer. Close supervision is necessary when any appliance is used by or near children. Do not allow deep cleaner to be used as a toy or to run unattended at any time. Do not point tools toward people or pets. Use only commercially available floor cleaners intended for machine application. Do not use any type of wax with deep cleaner. To assist In reducing drying time, be certain the area is well ventilated when using detergents and other cleaners with this machine. Keep detergents and other cleaners out of children's reach. Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present. Do not pick up chlorine bleach, drain cleaner, gasoline or any other toxic material with this appliance. Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes. Avoid picking up hard, sharp objects with the deep cleaner. They may damage the machine. Keep hair, loose clothing, fingers, feet and all parts of body away from openings and moving parts. Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow. To help prevent matting and resoiling, avoid contact with carpets until they are dry. Keep children and pets away from carpets until they are completely dry. Store in a dry place. Do not expose machine to freezing temperatures. Save these instructions! Grounding I n stru cti o n s A B © 0© C This appliance must be grounded, If it should malfunction or breakdown, grounding provides a path of least resis- tance for electrical current to reduce the risk of electric shock, This appliance is equipped with a cord having an equip- ment-grounding conductor (C) and grounding plug (A), The plug must be plugged into an appropriate outlet (B) that is properly installed and grounded in accordance with all local codes and ordinances, Carton contents DANGER- Improper connection of the equipment- grounding conductor can result in the risk of electric shock, Check with a qual- ified electrician or service person if you are in doubt as to whether the outlet is properly grounded, Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician, This appliance is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in sketch (A), A temporary adapter (D) may be used to connect this plug to a 2-pole receptacle (E) if a properly grounded outlet is not available, The temporary adapter should be used only until a properly grounded outlet (B) can be installed by a qualified electrician, The green colored rigid ear, lug, or the like (F) extending from the adapter must be connected to a perma- nent ground (G) such as a properly grounded outlet box cover, Whenever the adapter is used, it must be held in place by a metal screw, NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electrical Code, IIII A B E F C D G K M I J ._ s7 Unpack deep cleaner from the carton and identify the parts shown. Remove and dispose of the packing. A. Deep cleaner B. Upper handle with powered hand tool and scrub module C. Bolts (2) D. Nuts (3 - one extra included) E. Carpet/Upholstery Detergent F. Bare Floor Cleaner G. Bare floor attachment H. Hose holder I. Crevice tool J. Nozzle cleanout-tool Contained in carton with hose: K. Hose L. Stair/upholstery nozzle M. Tool holder and screw (taped on rack under nozzle) Continued -I_ 3 Theassembled cleanerwilllooklikethis I1_ drawing, Assemble handle Attach upper handle Remove clean solution tank (upper tank) from deep cleaner, A1 A2 I With hose hook (A1) and cord hook (A2) to back of deep cleaner, push upper handle down onto lower handle, Push bolts into holes on front of handle. If bolts will not go through hole easily handle is not pushed completely down. Attach hose holder Position hose holder (B) onto handle by matching tabs on rack with openings on back of handle, Make sure holes for bolts are aligned, Place nuts in recessed areas on back of handle, Hold each nut in place while tightening each bolt securely (from the front of the handle) with a Phillips screw driver, Only two nuts are needed on this model, The extra nut is not required but has been provided for your convenience, When handle sections are completely together, squeeze trigger (C) and depress Clean Surge TM Button (D) on upper handle, You will hear a "snap"when the trig- ger rod is in place, Replace clean solution tank (upper tank) by positioning bottom first, Press on tank handle to snap top of tank into place, 4 Attach tool holder Remove tool and taped screw from holder, Insert projections on holder into slots on back of cleaner, Slide rack down into place, Insert screw at (E) and tighten with a Phillips screw- driver,