NTC5/GNJ
NTN5/GNJ(NOxModels)
Upflow/Horizontal
Series
SAFETY
REQUIREMENTS
/X
Recognize
safety information.
This is the safety-alert
symbol _.
When you see this symbol
on the furnace and in instructions
manuals be alert to the potential for personal injury.
Understand
the signal words DANGER,
WARNING,
or CAUTION.
These words are used with the safety-alert
symbol.
DANGER
identifies the most serious hazards, those that will result in severe personal injury or death.
WARNING
signifies
a hazard that could
result in personal injury or death. CAUTION
is used to identify unsafe practices that could result in minor personal
injuryor prod uct and
property damage.
Installing and servicing heating equipment
can be hazardous
due to gas and electrical components.
Only trained and qualified person-
nel should
install, repair, or service
heating
equipment.
Untrained service personnel
can perform basic maintenance
functions
such as cleaning
and replacing air filters.
All other operations
must be performed
by trained service personnel.
When working
on heating equipment,
observe precautions
in the literature,
on tags,
and on labels attached to or shipped with the unit and other safety precautions that may apply.
Follow all safety codes.
In the United States, follow all safety codes includingthe current edition National Fuel Gas Code (NFGC) NFPA
No. 54/ANStZ223.1.
In Canada, refer to the current edition of the National Standard Canada CAN/CGA-B149.1
- and .2-M91
Natural
Gas and Propane Installation
Codes (NSCNGPI C). Wear safety glasses and work gloves.
Have fire extinguisher
available during start-
up and adjustment
procedures
and service
calls.
These instructions cover minimum
requirements
and conform to existing
national standards
and safety codes.
In some instances,
these
instructions
exceed certain
local codes and ordinances,
especially
those that may not have kept up with changing
residential
construction
practices.
We require these
instructions
as a minimum
for a safe installation.
Design Certified
byAGA
Manufactured
by:
International
Comfort
Products
Corporation
(USA)
Lewisburg,
TN USA 37091
Table of Contents
1. Installation...............................
2
2. Combustion& VentilationAir .................
4
3. GasVent Installation .......................
6
4. HorizontalVenting .........................
8
5. MasonryChimneyVenting ...................
8
6. GasSupplyand Piping ...................
7. ElectricalWiring ........................
8. DuctworkandFilter ......................
9. ChecksandAdjustments..................
10. FurnaceMaintenance ...................
9
12
13
14
16
This furnace is not designed for use in mobile
homes, trailers or recreational
vehicles. Such
use could result in property damage, bodily in-
jury and/or death.
LP1
2/10/98
441
01 2304
02
1. Installation
Installation
or
repairs
made
by
unqualified
persons can result in hazards to you and others.
Installation MUST conform with local codes or, in
the
absence
of local codes,
with codes
of all
governmental
authorities
having jurisdiction.
The
information
contained
in this
manual
is
intended for use by a qualified service technician
who is experienced
in such work, who is familiar
with
all
precautions
and
safety
procedures
required in such work, and is equipped with the
proper tools and test instruments.
Failure to carefully
read and follow all instruc-
tions
in this
manual
can
result
in
furnace
malfunction,
property
damage,
personal
injury
and/or death.
NOTE: This furnace
is design
certified
by the American
Gas
Association
and the Canadian
Gas Association
for installation
in
the United States and Canada.
Refer to the appropriate
codes,
along with this manual, for proper installation.
•
This furnace is NOT approved for installation
in mobile
homes, trailers or recreation vehicles.
•
Do NOT use this furnace as a construction
heater or to heat
a building that is under construction.
Use only the Type of gas approved
for this furnace
(see
Rating
Plate on unit). Overfiring will result in failure of heat
exchanger
and cause dangerous
operation.
(Furnace can
be converted
to LR
gas with approved
kit.)
•
Do NOT use open flame to test for gas leak.
•
Ensure
adequate
combustion
and ventilation
air is pro-
vided to the furnace.
•
Seal supply and return air ducts.
•
The vent system MUST be checked to determine
that it is
the correct type and size.
•
Install correct filter type and size.
•
Unit MUST be installed
so electrical
components
are pro-
tected from direct contact with water.
•
It is the suggestion
of this manufacturer
to install fire and
carbon monoxide
detectors.
B.
be gas-fired
clothes
dryers,
gas cooking
stoves,
water
heaters, furnaces,
gas-fired
fireplaces,
wood fireplaces,
and several other items. Carbon monoxide can cause seri-
ous bodily
injury and/or
death.
Therefore,
to help
alert
people of potentially
dangerous
carbon
monoxide
levels,
you should have carbon monoxide detectors
listed by a na-
tionally
recognized
agency
(e.g.
Underwriters
Laborato-
ries
or
International
Approval
Services)
installed
and
maintained
in the building or dwelling
(see Note below).
There can be numerous sources of fire or smoke in a build-
ing or dwelling.
Fire or smoke can cause serious bodily in-
jury, death, and/or property damage.
Therefore,
in order to
alert people
of potentially
dangerous
fire or smoke,
you
should have fire and smoke detectors
listed by Underwrit-
ers Laboratories
installed and maintained
in the building or
dwelling
(see Note below).
Note: The manufacturer
of your furnace does not test any detec-
tors and makes no representations
regarding any brand or
type of detector.
C.
To ensure
safe and efficient
operation
of your unit, you
should do the the following:
1.
Thoroughly
read this
manual
and labels on the unit.
This will help you understand
how your unit operates
and
the hazards
involved with gas and electricity.
2.
Do not use this
unit if any part has been under
water.
Immediately
call a qualified
service
technician
to inspect
the unit and to replace any part of the control system and
any gas control which has been under water.
3.
Never obstruct
the vent grilles,
or any ducts
that
pro-
vide air to the unit. Air must be provided for proper com-
bustion and ventilation
of flue gases.
Carbon monoxide or "CO" is a colorless and odorless
gas
produced
when fuel is not burned completely
or when the
flame does not receive sufficient oxygen.
Freezing Temperatures andYour Structure
Freeze warning.
Turn off water system.
If your unit remains shut off during cold weather
the water pipes could freeze and burst, resulting
in serious water damage.
Safety Rules
Your unit is built to provide
many years of safe and dependable
service providing it is properly installed and maintained.
However,
abuse and/or improper
use can shorten the life of the unit and
create hazards for you, the owner.
A.
The U.S. Consumer
Product Safety Commission
recom-
mends that users of gas-burning
appliances
install carbon
monoxide detectors.
There can be various sources of car-
bon monoxide in a building or dwelling. The sources could
Your unit is equipped with safety devices that may keep itfrom op-
erating if sensors detect abnormal conditions
such as clogged ex-
haust flues.
If the structure will be unattended
during cold weather
you should
take these precautions.
1.
Turn off main supply water into the structure
and drain the
water lines if possible. Open faucets
in appropriate
areas.
2.
Have someone
check the structure frequently
during cold
weather
to make sure it is warm enough to prevent pipes
from freezing. Suggest they call qualified service agency, if
required.
Poison carbon monoxide
gas hazard.
If
this
furnace
is
replacing
a
previously
common-vented
furnace, it may be necessary to
resize
the
existing
vent
line
and
chimney
to
prevent
oversizing
problems
for
the
other
remaining
appliances(s).
See applicable
codes
and Venting and Combustion
Air Check in Gas
Vent Installation
section.
Failure
to properly
vent
this furnace
or other
appliances
can
result
in
property
damage,
personal injury and/or death.
Locationand Clearances
If furnace is a replacement,
it is usually best to install the furnace
where the old one was. Choose the location or evaluate the exist-
ing location based upon the minimum
clearance
and furnace di-
mensions
(Figure
1).
CAUTION
Do NOT operate
furnace
in a corrosive
atmosphere
containing
chlorine,
fluorine
or any other damaging
chemicals.
Refer to Combustion
& Ventilation Air sec-
tion, Contaminated
Combustion
Air.
Figure 1
Dimensions
and Clearances
J
150,000BTUONLY
AirBaffleDONOTREMOVE
............
........
30i' rain.
2s-z_-_
DIMENSIONAL
INFORMATION
MINIMUM
CLEARANCES
TO
COMBUSTIBLE
MATERIALS
FOR
ALL
UNITS
REAR
0
FRONT
3" (75mm)*
For Service
30" (760mm)
ALL SIDES
Of SUPPLY PLENUM
1" (25mm)
SIDES
0
VENT
Single Wall Vent
6" (150mm)
Type B-1 Double Wall Vent
1" (25mm)
TOP OF FURNACE
6" (150mm)
* 6" with accessory
Masonry Chimney
drafthood
kit installe,
MODEL
CABINET
SUPPLY AIR
RETURN
AIR
GAS
CONNECTION
BOTTOM
SIDE
A
B
C
D
E
F
G
H
J
K
L
M
050BF / 075BF
40
151/2
281/2
181/2
14
231/8
125/8
121/4
221/2
281/4
26
237/8
075BH
40
191/8
281/2
181/2
175/8
231/8
143/4
141/2
221/2
281/4
26
237/8
1O0BF,1OOBJ
40
191/8
281/2
181/2
178/8
231/8
143/4
141/2
221/2
281/4
26
237/8
1O0BK
40
223/4
281/2
181/2
211/4
231/8
183/4
141/2
221/2
281/4
26
237/8
125BK / 15OBK
40
223/4
281/2
181/2
211/4
231/8
183/4
141/2
221/2
281/4
26
237/8
mm Equivalents
40=10t6
151/2 = 394
191/8 = 486
223/4 = 578
281/2 = 724
181/2 = 470
14 = 356
178/8=448
211/4 = 539
231/8 = 587
128/8 = 311
143/4 = 375
183/4 = 476
121/4 = 311
141/2 = 368
t7=
432
221/2 = 572
281/4 = 717
26 = 660
237/8 = 606
ALL DIMENSIONS
IN INCHES (ram)
Installation Requirements
1.
Install
furnace
level.
Install furnace as centralized
as practical with respect to the
heat distribution
system
• The 150,000 Btuh furnace
is manufactured
with an air
baffle to equalize air flow through the heat exchanger.
(See Figure
1).
DO NOT REMOVE THIS BRACKET