IgniteNet ICC-MMC-WW Manuals

1 pdf manual(s) IgniteNet ICC-MMC-WW for free download (Document Types: Quick start manual)

Document Preview & Text Transcription

– 1 – Quick Start Guide 1. Unpack and Check Contents ICC-MMC-WW Media Converter Grounding screw 2. Mount the Media Converter a. Mounting on a Pole Place the unit against the pole (diameter 20-200 mm). Use up to 12 mm (1/2 in) strapping to secure the unit to the pole. b. Mounting on a Wall In the required location, mark and drill three holes in the wall for M4 wall anchors (not included). Note: For a wood wall, drilling holes and using wall anchors is not required. Mount the unit on the wall and secure it in place using three M4 x20 tapping screws (not included). 2 1 1 2 2 1 1 2 3. Ground the Media Converter Ensure the structure on which the unit is to be mounted is properly grounded and in compliance with ETSI ETS 300 253. Verify that there is a good electrical connection to a grounding point (no paint or isolating surface treatment). Use the included screw to attach a grounding wire (not included) to the grounding point inside the unit, and then to ground. Caution: The earth connection must not be removed unless all supply connections have been disconnected. 4. Connect Power The media converter can be powered by a 24 to 48 VDC passive PoE injector or by connecting an external 24 to 48 VDC power source to its DC terminal block. a. PoE Power Connect Category 5e or better cable to the PoE Out/In RJ-45 port. Connecting Ethernet cable from an optional passive PoE injector can power on the unit. (Does not require a DC power connection.) Note: When powered by PoE, the DC terminal block provides a DC power output. When powered by a DC power input, the RJ-45 port functions as a PoE PSE (power source) port. In PoE PSE mode, the RJ-45 port pin definitions can be modified by a switch on the panel: ◆ IgniteNet: + (pins 1/2 & 4/5), - (pins 3/6 & 7/8) ◆ Other: + (pins 4/5), - (pins 7/8) In PoE input mode, the switch position has no function. 1 1 2 1 1 2-Port Media Converter ICC-MMC-WW www.ignitenet.com Quick Start Guide – 2 – b. DC Power Warning: Before wiring the DC block or connecting power to the device, ensure that power to the feed lines is turned off at the supply circuit breaker or disconnected from the power bus. Connect the DC power feed wire to the DC block “+” pin. Connect the ground/return wire to the DC block “-” pin. 5. Verify Switch Operation Verify basic switch operation by checking the system LEDs. When operating normally, the Power LED should be on green, and the LAN and Fiber SFP port LEDs should be on or blinking green. 6. Connect Fiber Cable First install an SFP transceiver, and then connect fiber optic cabling to the transceiver port. The following transceivers are supported: ◆ 1000BASE-SX ◆ 1000BASE-LX As the connection is made, check the Fiber SFP port status LED to be sure the link is valid: ◆ On Green — Port has a valid link. ◆ Blinking Green — Indicates network activity. 1 2 1 2 1 1 2 1 1 2 7. (Optional) Add Cable Strain-Relief Attachment The optional attachment provides strain relief for the Ethernet, fiber, and DC cables connected to the unit. Route the Ethernet and DC cables through the left side of the attachment. Route the fiber cable through the right side of the attachment and round the strain-relief feature at least once before exit. 2 1 1 2 Quick Start Guide – 3 – Safety and Regulatory Information FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. You may use unshielded twisted-pair (UTP) for RJ-45 connections - Category 3 or better for 10 Mbps connections, Category 5 or better for 100 Mbps connections, Category 5, 5e, or 6 for 1000 Mbps connections. For fiber optic connections, you may use 50/125 or 62.5/125 micron multimode fiber or 9/125 micron single-mode fiber. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CE Mark CE Mark Declaration of Conformance for EMI and Safety (EEC) This information technology equipment complies with the requirements of the Council Directive 2014/30/EC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 2014/35/EC for electrical equipment used within certain voltage limits. For the evaluation of the compliance with these Directives, the following standards were applied: RFI Emission: ◆ Limit according to EN 55032:2012/AC:2013, Class A ◆ Limit for harmonic current emission according to EN 61000-3- 2:2014, Class A ◆ Limitation of voltage fluctuation and flicker in low-voltage supply systems according to EN 61000-3-3:2013 Immunity: ◆ Product family standard according to EN 55024:2010, Class A ◆ Electrostatic Discharge according to IEC 61000-4-2:2008 ED. 2.0 ◆ Radio-frequency electromagnetic field according to IEC 61000-4- 3:2010 ED. 3.2 ◆ Electrical fast transient/burst according to IEC 61000-4-4:2012 ED. 3.0 ◆ Surge immunity test according to IEC 61000-4-5:2014 ED. 3.0 ◆ Immunity to conducted disturbances, Induced by radio-frequency fields: IEC 61000-4-6:2013 ED. 4.0 ◆ Power frequency magnetic field immunity test according to IEC 61000-4-8:2009 ED. 2.0 ◆ Voltage dips, short interruptions and voltage variations immunity test according to IEC 61000-4-11:2004 ED. 2.0 LVD: ◆ EN 60950-1:2006+A1:2010+A11:2009+A12:2011+A2:2013 The Declaration of Conformity (DoC) can be obtained from www.ignitenet.com/support. Laser Safety Warning: Fiber Optic Port Safety: Avertissment: Ports pour fibres optiques - sécurité sur le plan optique: Warnhinweis: Faseroptikanschlüsse - Optische Sicherheit: Warnings and Cautionary Messages When using a fiber optic port, never look at the transmit laser while it is powered on. Also, never look directly at the fiber TX port and fiber cable ends when they are powered on. Ne regardez jamais le laser tant qu'il est sous tension. Ne regardez jamais directement le port TX (Transmission) à fibres optiques et les embouts de câbles à fibres optiques tant qu'ils sont sous tension. Niemals ein Übertragungslaser betrachten, während dieses eingeschaltet ist. Niemals direkt auf den Faser- TX-Anschluß und auf die Faserkabelenden schauen, während diese eingeschaltet sind. Warning: This product does not contain any serviceable user parts. Warning: Installation and removal of the unit must be carried out by qualified personnel only. Warning: This product uses lasers to transmit signals over fiber optic cable. The lasers are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation. However, you should never look directly at a transmit port when it is powered on. Warning: When selecting a fiber SFP device, considering safety, please make sure that it can function at a temperature that is not less than the recommended maximum operational temperature of the product. You must also use an approved Laser Class 1 SFP transceiver. Caution: Wear an anti-static wrist strap or take other suitable measures to prevent electrostatic discharge when handling this equipment. Caution: Do not plug a phone jack connector in the RJ-45 port. This may damage this device. Caution: Use only twisted-pair cables with RJ-45 connectors that conform to FCC standards. CLASS 1 LASER DEVICE DISPOSITIF LASER DE CLASSE 1 LASERGER T Ä DER KLASSE 1