IR-Tec OS-551DT Manuals

1 pdf manual(s) IR-Tec OS-551DT for free download (Document Types: Installation instructions)

IR-Tec OS-551DT Installation instructions [PDF] (2 pages)

  • Identifier: id-856343
  • Brand: IR-Tec
  • Device: OS-551DT Kitchen Appliances
  • Type: PDF
  • Key Aspects: Step-by-Step Assembly Procedures, Control Panel and Interface Navigation, Initial Startup Checklist
  • UPD Date: 19.08.2026
  • Source File: 888233.pdf
  • Pages: 2
  • Description: Service manual for the IR-Tec OS-551DT.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Hot Black White Red Red Black Brown Green White Red Black Blue Red Neut Relay Relay DC24V GND COM AC/DC NO NC MS DIM Control Hot 120~277V Neutral OS-551DT PPU-301 Load Hot Neut Yellow Orange Violet Grey OVERVIEW The OS-551DT comes with pigtail wires for connection to the corresponding wires of IR-TEC power pack or BMS control. Each IR-TEC PPU-300/301 power pack can supply power for up to 6 OS-551DT sensors. When more sensors are connected, multiple power packs may be required. Low Voltage Dual-Tech Occupancy Sensor OS-551DT INSTALLATION INSTRUCTIONS APPLICATION NOTES PIR sensor is more sensitive to the movements “crossing” the detection zones than “toward” or “away” the sensor unit. Avoid placing the sensor in line with the path of occupant, if possible. In general, mounting the sensor at corner area gives better detection. PIR sensor cannot “see” the movements behind obstacles, such as furniture, shelf, glass or partitions. As a general rule, ensure to place the sensor at where the occupant could have clear view of the sensor. HFD sensor may penetrate through certain types of non-metallic partition material (glass, plaster, plywood…etc) and detects the traffics outside of desired range. Ensure to adjust the HFD sensitivity to achieve optimal detection range. Place the sensor at least at 5 ft. (1.5m) away from air supply duct and fluorescent lighting to avoid false activating. For open office areas with partition which could block the sensor view to occupant movements, it is recommended to place the sensors over the intersection of multiple workstations. For large areas of open office or space, place multiple sensors so that there is overlap coverage with each adjacent sensor. 1. 2. 3. 4. 5. WIRING DIAGRAM A. Auto-ON/Auto-OFF with PPU-301 B. Manual-ON/Auto-OFF and Auto-DIM with PPU-300 Hot Black White Red Red Black Brown Green White Red Black Blue Red Neut Relay Relay DC24V COM AC/DC NO NC MS DIM Control Manual Hold ON Hold OFF Hot 120~277V Neutral OS-551DT DIM Dimmable light 1-10V Hot Neut Yellow Orange Violet Violet Grey Grey Momentary Button PPU-300 DC24V GND Control Manual Hold ON Hold OFF Orange Grey Brown The OS-551DT is a low voltage dual technology occupancy sensor designed to signal the occupancy status for area lighting, or HVAC control, for energy efficient building management. The sensor combines a cutting edge Passive Infrared (PIR) sensor, a state-of-the-art High Frequency Doppler (HFD) sensor, and advanced signal processing firmware into one unit to perform superior occupancy sensing capability. The OS-551DT is ideal for the areas where motion may not be easily detectable by a single technology sensor. The OS-551DT is operated by 24V low voltage power. When PIR sensor detects the presence of occupant within its coverage, the sensor will activate a form C dry contact for a period of OFF-delay time as programmed. The delay timer will be reset if any motion is detected by either PIR or HFD sensor before delay time elapsed. An ON-delay can be enabled to prohibit short-cycle restart or unwanted load activation if the sensor is used to control HVAC operation. Both ON and OFF delays can be easily set via two rotary DIP switches on board. A potentiometer allows the HFD sensitivity adjustment. The sensor output can be set to inhibit when ambient light level is higher than the threshold programmed. The ECG analog output is available for constant level lighting control. This sensor offers numerous control options which can be enabled, or disabled via a 6-pole DIP switch on board. 3 LED’s are available to indicate the sensing status which can be disabled if necessary. A built-in buzzer can be enabled to provide audible Delay-End Warning (DEW) at the end of OFF-delay. The SmartDelay can be enabled to automatically adjust the OFF-delay based on the duration of previous occupancies. Walk-Through mode can be enabled to turn the light off 3 minutes after the area is initially occupied but with no motion detected in the next 30 seconds. The FORCE-OFF delay can also be applied if HFD sensor may detect the out-of-range motions thus result in unwanted OFF-delay extensions. The sensitivity of PIR sensor can be reduced for harsh environment. SPECIFICATIONS Power supply Current drain Output contact Infrared sensor HFD sensor Detectable speed Mounting height Detection range ON-delay setting OFF-delay setting ALS level setting Manual override FORCE-OFF delay Walk-thru mode Op. humidity Op. temperature Dimensions 22~26 VAC/DC 20 mA @ 24 VAC, standby mode Form C, max. 5A resistive load Dual element pyroelectric sensor X-band DRO type, patch antenna 0.33 ~ 10 ft/sec. (0.1 ~ 3 m/sec.) 6 ~ 12 ft (1.8 ~ 3.6 m) 110°, 50 ft @ 77°F (25°C) 0(disabled)/5”/10”/20”/30”/1’/3‘/5’ 10”/1’/3’/5’/10’/20’/30’/60’ 4-level, 2~2,000 lux Momentary contact 5 times of OFF-delay set, if enabled 3 min. if no motion within 30 sec. Max. 95% RH -14°F ~ 122°F (-10°C ~ 50°C) 4.4”x2.6”x1.8” (112 x 66 x 45 mm) P/N: 058-55100-005 Printed in Taiwan www.irtec.com This product may be covered by one or more U.S. patents or patent applications. Please visit www.irtec.com for more information. Turn power OFF at circuit breaker before connecting Power Pack or Sensor. CAUTION This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, (2)This device must accept any interference received, Including interference that may cause undesired operation. FCC NOTES: FCC ID: NRIOS-551DT Wire all Class 2 circuits using types CL3, CL3P, CL3R, or equivalent conductors. Coupez l'alimentation au disjoncteur avant d'installer Power Pack ou capteurs. PRUDENCE Câble toute classes 2 circuits CL3, CL39, CL3R ou conducteur équivalent Install the sensor at least 1ft. away from any occupant. INDOOR USE ONLY Utilisation a L'interieur Uniquement

IR-Tec OS-551DT: Kitchen Appliances Category Related Instructions

FX-301
Sunx FX-301
15.07.2026 60 pages

1. Functional Description 1-1. Functional Description..........................P.1 1-2. Setting Procedure.................................P.1 2. Diagram of Functions and Settings 2-1. Diagram of Functions and Settings......P.2 3. Others 3-1. Precautions When S Operation and maintenance manual for the Sunx FX-301 Amplifier. The guide outlines procedures for safety guidelines, connectivity options, safety.

ADL-SR
Meier-NT ADL-SR
19.05.2026 7 pages

Meier-NT GmbH · Rittergutsweg 5 · 08297 Zwönitz · Tel. 037754 304 0 CEO Dipl. Ing.(FH) Heiko Meier · HRB 25917 Amtsgericht Chemnitz 1 Instruction manual ADL-SR® Quick start guide for the Meier-NT ADL-SR Kitchen Appliances. The manual provides step-by-step instructions on device safety checks, firmware installation, troubleshooting.

CSB-75 Series
Cuisinart CSB-75 Series
13.06.2026 22 pages

INSTRUCTION/ RECIPE BOOKLET For your safety and continued enjoyment of this product, always read the instruction book carefully before using. Smart Stick® Two Speed Hand Blender CSB-75 Series Instruction booklet for the Cuisinart CSB-75 Series Kitchen Appliances. This documentation details assembly reference, setup validation, backup procedures, wiring setup.

SS340 Series
tau SS340 Series
07.04.2026 10 pages

Manuale utente (originale) SS340 Sensore di sicurezza per porte battenti SS340S1 SS340M1 SS340L1 1 Descrizione generale / caratteristiche 2 Componenti Nella figura qui sotto è illustrata la configurazione standard di SS340L1con una singola unità PCB. 3 Infor Professional manual for the tau SS340 Series Kitchen Appliances. The manual details dimensions and layout, cleaning instructions, network setup, installation guides.