jablotron JA-160PC Manuals

4 pdf manual(s) jablotron JA-160PC for free download (Document Types: Manual , Quick start manual)

jablotron JA-160PC Manual  [PDF] (3 pages)

  • Identifier: id-1705673
  • Brand: jablotron
  • Device: JA-160PC Security Sensors
  • Type: PDF
  • Key Aspects: Regulatory Compliance and Standards, Model Variations and Compatibility, Technical Data and Parameters
  • UPD Date: 27.06.2026
  • Source File: 1731536.pdf
  • Pages: 3
  • Description: Instructions for safe usage of the jablotron JA-160PC.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
JABLOTRON ALARMS a.s. Pod Skalkou 4567/33 46601 Jablonec n. Nisou Czech Republic www.jablotron.com | | | JA-160PC (90) PIR motion BUS detector with a 90° verification camera JA-160PC (90) PIR motion BUS detector with a 90° verification camera 1 / 3 MMQ53102 This device is a wireless component of the JABLOTRON JA-100 system. It serves for the detection of human movement in building interiors and visual alarm confirmation. The camera takes colour photos with a resolution of up to 640x480 pixels. Photos are taken following detected movement, which ensures that the cause of the alarm is always recorded. The camera is equipped with a visible flash for taking photos in the dark. The images are saved in the internal memory of the detector and then they are forwarded to the control panel via radio signal and from the control panel they can be sent to MyJABLOTRON, ARC and users. The detector can also take a photo by request. The detector should be installed by a trained technician with a valid certificate issued by an authorised distributor. Installation The detector can be installed on the wall or in the corner of a room. There should be no objects which quickly change temperature (e.g. heating appliances) or which move (e.g. curtains hanging above a radiator, robotic vacuum cleaners) or pets in the detector’s field of sight. It is not recommended installing the detector opposite windows or in places with intense air circulation (close to ventilators, heat sources, air conditioning outlets, unsealed doors, etc.). There should be no obstacles in front of the detector which might obstruct its view of the protected area. Figure: 1 – flash for illumination; 2 – camera lens; 3 – PIR detector lens; 4 – cover tab; Avoid installation too close to a ceiling. Using flash may cause over-exposure of the scene due to reflections. 1. Open the detector cover (by pushing the cover tab (4)). Avoid touching the PIR sensor inside (15) – you could damage it. 2. Take out the PCB – it is held by a tab (9). 3. The recommended installation height is 2.5 m above the floor. 4. Attach the plastic base to the wall using screws (vertically, with the cover tab facing downwards). 5. Re-insert the PCB and plug the connecting cable (6) into the connector on the PCB. Figure: 5 – Camera module; 6 – connection cable; 7 – batteries; 8 – red LED indicator; 9 – PCB tab; 10 – yellow LED; 11 – yellow LED indicator of Micro SD card; 12 – Micro SD memory card; 13 – mini USB connector; 14 – tamper contact; 15 – PIR sensor; 16 – production code. 6. Proceed according to the control panel installation manual. Basic procedure: a. The control panel must contain already enrolled JA-11xR radio module. b. Go to the F-Link software, select the required position in the Devices tab and launch the enrolment mode by clicking on the Enroll option. c. Insert the batteries (mind the correct polarity). When the second battery has been inserted into the detector, an enrollment signal is transmitted to the control panel and the detector is enrolled to the selected position. This is followed by up to three minutes detector stabilization phase indicated by the illuminated red LED indicator. If discharged batteries have been inserted the red LED indicator flashes for 3 minutes. d. If the detector is enrolled as the first PIR camera or the control panel is not connected to an external mass storage, F-Link shows a dialogue window with the question: “Enable image transfer to external storage?” We recommend enabling this option with the agreement of the customer and confirming this acceptance by recording it in the system service log with his signature. Note: If the transmission is not enabled, images will be saved in the internal memory of the detector and the control panel only. Then it is impossible to send them to users’ cell phones and e-mails. 7. Close the detector cover and test its functionality. When the detector has been closed, it starts the 15 minute test mode during which it indicates and reports every movement. After that, the red LED will not indicate movement and the detector works in the standard mode. Notes: - When the control panel is in service mode, the detector indicates every movement with the red LED indicator. - If you want to enroll the detector in the control panel after the battery has already been inserted, remove the battery first and then press and release the tamper contact (14) to discharge the rest of the energy and then enroll the detector. - The detector can be enrolled by entering the production code (16) in the F-Link software (or a bar code reader). Enter all digits located below the bar code (1400-00-0000-0001). - If you want to remove the detector from the system, erase it from its position in the control panel. - In order to comply with the EN 50131-2-4 norm, the cover tab (4) must be secured with the supplied screw. Detector internal settings Settings can be set by F-Link software in the Devices tab. Use the Internal settings option on the detector’s position to open a dialog window where you can configure the settings (* default settings): PIR immunity level: Defines false alarm immunity. The *Standard level combines basic immunity with a rapid reaction. The Increased level provides higher immunity but the detector reaction is slower. LQ photo quality: Standard* quality uses optimized compression in order to achieve the fastest possible transfer to the ARC or to the end user in MyJABLOTRON. The goal is achieving alarm verification in the fastest time possible. If the quality is switched to Extended, the system will use lower image compression which will at least double the time necessary to transfer the image (depends on the conditions of the captured scene). Change the quality only if the LQ image does not have the quality required by the customer – it may depend on the captured space. It is not recommended when there are more verification detectors in the premises which may take images at the same time. Taking photos during alarms: No flash, *With flash Flash intensity: Low, *Medium, High – if the captured scene is over- exposed (e.g.in a small room), the intensity of the flash can be decreased. It can be increased for larger spaces. Lithium battery operation: If the detector is tasked with frequent operation (e.g. frequently requested photos by MyJABLOTRON) and is configured to high flash intensity, we recommend the use of AA 1.5 V lithium batteries. If you operate the detector from lithium batteries, this parameter must be enabled (it adjusts detection of low batteries). PG output reaction: You can select PG outputs, whose activation will trigger taking a picture (* No, camera does not react to PG). For further info see Installation recommendations, cautions. Taking a photo by PG activation: No flash, *With flash Taking photos during entrance delay: *No flash, With flash Send pre-alarm photos: This option is not available when the Extended LQ photo quality is selected due to more than double size of the photo and therefore longer transmission time. When this parameter is enabled the detector will send photos even when the detector is configured with repeated or confirmed reaction and the alarm has not been confirmed. During every entrance delay, up to two photos can be taken when the detector is triggered even when the system has been unset properly. This option will noticeably increase the volume of data transferred to MyJABLOTRON or external mass storage. If the system is unset (alarm is triggered), the images taken during the entrance delay will be sent automatically regardless this option Test: takes a test photo (LQ) with a flash and F-Link displays it. When the Detail button is pressed, the F-Link software shows the picture in a 640x480 px resolution. Photos are sent to the external mass storage (provided that transferring is enabled). To set the JA-160PC (90) detector to comply with security grade 2 or other requirements use F-Link SW, Parameters tab and the option “System profiles”. Camera and basic reactions The process of how the camera takes pictures depends on the settings in the F-Link software – the Devices tab. Choose a type of Reaction on the detector’s position.

jablotron JA-160PC Quick start manual [PDF] (2 pages)

  • Identifier: id-1812237
  • Brand: jablotron
  • Device: JA-160PC Security Sensors
  • Type: PDF
  • Key Aspects: Warranty and Service Information, Troubleshooting Information, Glossary of Technical Terms
  • UPD Date: 26.07.2026
  • Source File: 1910530.pdf
  • Pages: 2
  • Description: Device setup guide for the jablotron JA-160PC.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
JA-160PC Wireless PIR motion detector combined with a camera JA-160PC Wireless PIR motion detector combined with a camera 1 / 2 MMQ51100 The JA-160PC is wireless component of the JABLOTRON 100 system. It serves for the detection of human movement in building interiors and visual alarm confirmation. The camera takes colour photos with a resolution of up to 640 x 480 pixels by detecting human movement while the system is set. The camera is equipped with a visible flash for taking photos in the dark. The images are saved in the internal memory of the detector and then they are forwarded to the control panel. From the control panel they can be sent to an external mass storage area, ARC and a user. The detector can also take a photo on command if it is required (e.g. fire alarm confirmation). The detector should be installed by a trained technician with a valid certificate issued by an authorised distributor. Installation The detector can be installed onto a wall or in the corner of a room. There should be no obstacles which quickly change temperature (electric heaters, gas appliances, etc.) or which move (e.g. curtains hanging above a radiator) or pets in the detector´s field of sight. It is not recommended to install the detector opposite to windows or floodlights or in places with over-intense air circulation (close to ventilators, heat sources, air conditioning outlets, unsealed doors, etc.). There should be no obstacles in front of the detector which might obstruct its view. Figure: 1 – flash for illumination; 2 – camera lens; 3 – PIR detector lens; 4 – cover tab; 1. Open the detector cover by pushing the tab (4). Avoid touching the PIR sensor inside (15) – you could damage it. 2. Take out the PCB – it is held by a tab (9). 3. The recommended installation height is 2.5 m above the floor. 4. Screw the rear cover to the wall (vertically, cover tab down). 5. Return the PCB. Figure: 5 – Camera module; 6 – connection cable; 7 – batteries; 8 – red LED; 9 – PCB tab; 10 – yellow LED; 11 – yellow LED of micro SD card; 12 – Micro SD memory card; 13 – mini USB connector; 14 – tamper contact; 15 – PIR sensor; 16 – production code. 6. Leave the battery disconnected and the cover open and then follow the control panel installation manual. The basics of enrollment are: a. There must be a JA-110R radio module installed in the control panel. b. Go to the F-Link software, select the required position in the Devices window and launch the enrollment mode by clicking on the Enroll option. c. Insert the batteries (mind the correct polarity). When the second battery has been inserted into the detector, an enrollment signal is transmitted to the control panel and the detector is enrolled to the selected position. This is followed by up to three minute detector stabilization phase indicated by the LED indicator flashing. If the discharged batteries have been inserted the red LED indicator flashes for 3 minutes. If the detector is enrolled as the first PIR camera or the control panel is not connected to an external mass storage area, F-link shows a dialogue window with the question: “Enable image transfer to the IMG server?” We strictly recommend enabling this option with the agreement of the customer and confirming this acceptance by recording it in the system service log with his signature. Note: If the transmission is not enabled, photos will be saved in the internal memory of the detector and the control panel. Then it is impossible to send them to users’ cell phones and e-mails. 7. Close the detector cover and check its functions. When the detector has been closed, it starts the 15 minute test mode when every detected movement is indicated by the red LED and sent to the control panel. Notes: If you want to enroll the detector to the control panel when the battery has already been inserted, remove the battery first and then press the tamper contact (14) a few times (for discharging the rest of the energy) and then enroll the detector. The detector can also be enrolled to the system by entering its production code (16) in the F-link software (or using a bar code scanner). All numbers stated under the bar code shall be entered (1400-00-0000-0001). Detector internal settings The detector properties can be set by F-Link software (version 1.1.1 and higher) – Devices tab. When at the detector position, use the Internal settings option to open a dialog window where you can configure the settings (* default settings): PIR immunity level: Defines false alarm immunity. The *Standard level combines basic immunity with a rapid reaction. The Increased level provides higher immunity but the detector reaction is slower. PG output reaction: select the PG outputs, by whose activation a photo is taken (* No, camera does not react to PG). For further info see Installation recommendations, cautions Taking picture after PG activation: No flash, *With flash Photo taking during entrance delays: *No flash, With flash Photo taking during alarms: No flash, *With flash Send pre-alarm image: When this parameter is enabled the detector will send photos from a set section when an alarm has not been triggered yet (for example: during an entrance delay). Test: takes a test picture with a flash and F-link shows it. When the Detail button is pressed, F-Link shows the picture with a 640 x 480 pix resolution. Pictures are sent to the external mass storage area (if it is enabled). Camera and basic reactions The processing of how the camera takes pictures depends on the settings in the F-link software – Devices tab. Choose the Reaction button on a particular detector line. Instant: During one setting period the camera can be triggered 4 x (then it is auto-bypassed). For every detected movement it takes 2 photos maximum. Photos are sent to the control panel (8 photos maximum). Delay: The first activation (entrance delay) takes up to 2 photos according to the detected movement and saves them into the internal memory (Send pre-alarm image disabled). When an alarm is triggered, photos are sent from the internal memory to the control panel. Then the behaviour is the same as an instant reaction. (10 photos maximum). Caution: When in Settings/Parameters “Bypass after 3 x triggering” is enabled, then taking photos is blocked after the 3rd repetition. The number of taken and transferred photos could be 3 times bigger (max. 3 x 4 activations during one setting period). Detection characteristics The standard lens that is supplied with the JA-160PC detector covers an area of 55°/12m – see picture. The detection characteristics don´t have an influence on the camera part. The lens must not be changed for any other type. The camera always has a viewing angle of 43°, the camera flash has a 3 m range.

jablotron JA-160PC Quick start manual [PDF] (2 pages)

  • Identifier: id-1983509
  • Brand: jablotron
  • Device: JA-160PC Security Sensors
  • Type: PDF
  • Key Aspects: Periodic Inspection Checklists, Component Longevity Optimization, FAQ Section for Common Queries
  • UPD Date: 26.08.2026
  • Source File: 2304350.pdf
  • Pages: 2
  • Description: Installation guide for the jablotron JA-160PC.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
JABLOTRON ALARMS a.s. Pod Skalkou 4567/33 46601 Jablonec n. Nisou Czech Republic www.jablotron.com | | | JA-160PC Wireless PIR motion detector with a verification camera JA-160PC Wireless PIR motion detector with a verification camera 1 / 2 MMQ51105 The JA-160PC is wireless component of the JABLOTRON 100 system. It serves for the detection of human movement in building interiors and visual alarm confirmation. The camera takes colour photos with a resolution of up to 640 x 480 pixels by detecting human movement while the system is set. The camera is equipped with a visible flash for taking photos in the dark. The images are saved in the internal memory of the detector and then they are forwarded to the control panel. From the control panel they can be sent to MyJABLOTRON or ARC. The detector can also take a photo on request. The detector takes one position in the system and should be installed by a trained technician with a valid certificate issued by an authorised distributor. The photo-verification can be used only after the registration of the system to MyJABLOTRON or with subsequent ARC service. Installation The detector can be installed onto a wall or in the corner of a room. There should be no obstacles which quickly change temperature (e.g. heating appliances,) or which move (e.g. curtains hanging above a radiator, robotic vacuum cleaners, pets) in the detector´s field of sight. It is not recommended to install the detector opposite to windows or in places with over-intense air circulation (close to ventilators, heat sources, air conditioning outlets, unsealed doors, etc.). There should be no obstacles in front of the detector which might obstruct its view of the protected area. Figure: 1 – flash for illumination; 2 – camera lens; 3 – PIR detector lens; 4 – cover tab; Avoid installation too close to a ceiling. Using flash may cause over-exposure of the scene due to reflections. 1. Open the detector cover by pushing the tab (4). Avoid touching the PIR sensor inside (15) – you could damage it. 2. Take out the PCB – it is held by a tab (9). 3. The recommended installation height is 2.5 m above the floor. 4. Screw the rear cover to the wall (vertically, cover tab down). 5. Re-insert the PCB and plug the connecting cable (6) into the connector on the PCB. Figure: 5 – Camera module; 6 – connection cable; 7 – batteries; 8 – red LED; 9 – PCB tab; 10 – yellow LED; 11 – yellow LED of Micro SD card; 12 – Micro SD memory card; 13 – mini USB connector; 14 – tamper contact; 15 – PIR sensor; 16 – production code. 6. Proceed according to the control panel installation manual. Basic procedure: a. There must be a JA-11xR radio module installed in the control panel. b. Go to the F-Link software, select the required position in the Devices window and launch the enrollment mode by clicking on the Enroll option. c. Insert the batteries (mind the correct polarity). When the second battery has been inserted into the detector, an enrollment signal is transmitted to the control panel and the detector is enrolled to the selected position. This is followed by up to three-minute detector stabilization phase indicated by the LED indicator flashing. If the discharged batteries have been inserted the red LED indicator flashes for 3 minutes. d. If the detector is enrolled as the first PIR camera or the control panel is not connected to MyJABLOTRON, F-link shows a dialogue window with the question about enabling data transfer. We recommend enabling this option with the agreement of the customer and confirming this acceptance by recording it in the system service log with his signature. Note: If the transmission is not enabled, photos will be saved in the internal memory of the detector and the control panel. Then it is impossible to send them to MyJABLOTRON and ARC. 7. Close the detector cover and test its functionality. Notes: - When the control panel is in service mode, the detector indicates every movement with the red LED indicator. - If you want to enroll the detector in the control panel after the battery has already been inserted, remove the battery first and then press and release the tamper contact (14) to discharge the rest of the energy and then enroll the detector. - The detector can be enrolled by entering the production code (16) in the F-Link software (or a bar code reader). Enter all digits located below the bar code (1400-00-0000-0001). - If you want to remove the detector from the system, erase it from its position in the control panel. - In order to comply with the EN 50131-2-4 norm, the cover tab (4) must be secured with the supplied screw. Detector internal settings Settings can be set by F-Link software in the Devices tab. Use the Internal settings option on the detector’s position to open a dialog window where you can configure the settings (* default settings): PIR immunity level: Defines false alarm immunity. The *Standard level combines basic immunity with a rapid reaction. The Increased level provides higher immunity but the detector reaction is slower. PG output reaction: You can select PG outputs, whose activation will trigger taking a picture (* No, camera does not react to PG). For further info see Installation recommendations, cautions. Taking a photo by PG activation: No flash, *With flash Taking photos during entrance delay: *No flash, With flash Taking photos during alarms: No flash, *With flash Flash intensity: Low, *Medium, High – if the captured scene is over-exposed (e.g.in a small room), the intensity of the flash can be decreased. It can be increased for larger spaces (this option can decrease a battery lifetime). Increased number of photos during alarm: When enabled, 3 photos are sent instead of 2 during each alarm event, that means more data transfer between the detector and the control panel and between the control panel and MyJABLOTRON or ARC. Enabling this option will decrease a battery lifetime. This option is for specific markets so we don’t recommend enabling by default. Send pre-alarm photos: This option is not available when the Extended LQ photo quality is selected due to more than double size of the photo and therefore longer transmission time. When this parameter is enabled the detector will send photos even when the detector is configured with repeated or confirmed reaction and the alarm has not been confirmed. During every entrance delay, up to two photos can be taken when the detector is triggered even when the system has been unset properly. This option will noticeably increase the volume of data transferred to MyJABLOTRON. If the system is not unset (alarm is triggered), the images taken during the entrance delay will be sent automatically regardless this option. Lithium battery operation: If the detector is tasked with frequent operation (e.g. frequently requested photos by MyJABLOTRON) and is configured to high flash intensity, we recommend the use of AA 1.5 V lithium batteries. If you operate the detector from lithium batteries, this parameter must be enabled (it adjusts detection of low batteries). Test: takes a test photo (LQ) with a flash and F-Link displays it. When the Detail button is pressed, the F-Link software shows the picture in a 640 x 480 px resolution. Photos are sent to MyJABLOTRON (provided that transferring is enabled). Camera and basic reactions The processing of how the camera takes pictures depends on the settings in the F-link software – Devices tab. Choose the Reaction button on a particular detector line. Instant: During an alarm triggered by the detector, the camera can be activated up to 3 times (then it will be auto-bypassed). Each activation, depending on the detected movement and settings, takes 3 photos maximum. Photos are sent to the control panel (9 photos maximum). Delay: The first activation (entrance delay) takes up to 2 photos according to the detected movement and saves them into the internal memory (Send pre- alarm image disabled). When an alarm is triggered, photos are sent from the internal memory to the control panel. Then the behaviour is the same as an instant reaction (11 photos maximum). Caution: When the Device autobypass / 3rd alarm is enabled (located in Settings/Parameters), then taking photos is blocked after the 3rd alarm. During each alarm the detector can be triggered up to three times. This way, the number of taken and transferred photos can be tripled (18/24 photos). Applies to Instant / Delayed reactions.

jablotron JA-160PC Quick start manual [PDF] (2 pages)

  • Identifier: id-1983511
  • Brand: jablotron
  • Device: JA-160PC Security Sensors
  • Type: PDF
  • Key Aspects: User Training Recommendations, Additional Modules and Accessories Guide, Pre-Deployment Preparation Steps
  • UPD Date: 11.06.2026
  • Source File: 2304348.pdf
  • Pages: 2
  • Description: Detailed operating instructions for the jablotron JA-160PC.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
JABLOTRON ALARMS a.s. Pod Skalkou 4567/33 46601 Jablonec n. Nisou Czech Republic www.jablotron.com | | | JA-160PC (90) PIR motion BUS detector with a 90° verification camera JA-160PC (90) PIR motion BUS detector with a 90° verification camera 1 / 2 MMQ53103 This device is a wireless component of the JABLOTRON 100 system. It serves for the detection of human movement in building interiors and visual alarm confirmation. The camera takes colour photos with a resolution of up to 640x480 pixels. Photos are taken following detected movement, which ensures that the cause of the alarm is always recorded. The camera is equipped with a visible flash for taking photos in the dark. The images are saved in the internal memory of the detector and then they are forwarded to the control panel and from the control panel they can be sent to MyJABLOTRON or ARC. The detector can also take a photo by request. The detector takes one position in the system and should be installed by a trained technician with a valid certificate issued by an authorised distributor. The photo-verification can be used only after the registration of the system to MyJABLOTRON or with subsequent ARC service. Installation The detector can be installed on the wall or in the corner of a room. There should be no objects which quickly change temperature (e.g. heating appliances) or which move (e.g. curtains hanging above a radiator, robotic vacuum cleaners, pets) in the detector’s field of sight. It is not recommended installing the detector opposite windows or in places with intense air circulation (close to ventilators, heat sources, air conditioning outlets, unsealed doors, etc.). There should be no obstacles in front of the detector which might obstruct its view of the protected area. Figure: 1 – flash for illumination; 2 – camera lens; 3 – PIR detector lens; 4 – cover tab; Avoid installation too close to a ceiling. Using flash may cause over-exposure of the scene due to reflections. 1. Open the detector cover (by pushing the cover tab (4)). Avoid touching the PIR sensor inside (15) – you could damage it. 2. Take out the PCB – it is held by a tab (9). 3. The recommended installation height is 2.5 m above the floor. 4. Attach the plastic base to the wall using screws (vertically, with the cover tab facing downwards). 5. Re-insert the PCB and plug the connecting cable (6) into the connector on the PCB. Figure: 5 – Camera module; 6 – connection cable; 7 – batteries; 8 – red LED indicator; 9 – PCB tab; 10 – yellow LED; 11 – yellow LED indicator of Micro SD card; 12 – Micro SD memory card; 13 – mini USB connector; 14 – tamper contact; 15 – PIR sensor; 16 – production code. 6. Proceed according to the control panel installation manual. Basic procedure: a. The control panel must contain already enrolled JA-11xR radio module. b. Go to the F-Link software, select the required position in the Devices tab and launch the enrolment mode by clicking on the Enroll option. c. Insert the batteries (mind the correct polarity). When the second battery has been inserted into the detector, an enrollment signal is transmitted to the control panel and the detector is enrolled to the selected position. This is followed by up to three minutes detector stabilization phase indicated by the illuminated red LED indicator. If discharged batteries have been inserted the red LED indicator flashes for 3 minutes. d. If the detector is enrolled as the first PIR camera or the control panel is not connected to an external mass storage, F-Link shows a dialogue window with the question about enabling data transfer. We recommend enabling this option with the agreement of the customer and confirming this acceptance by recording it in the system service log with his signature. Note: If the transmission is not enabled, images will be saved in the internal memory of the detector and the control panel only. Then it is impossible to send them to MyJABLOTRON or ARC. 7. Close the detector cover and test its functionality. Notes: − When the control panel is in service mode, the detector indicates every movement with the red LED indicator. − If you want to enroll the detector in the control panel after the battery has already been inserted, remove the battery first and then press and release the tamper contact (14) to discharge the rest of the energy and then enroll the detector. − The detector can be enrolled by entering the production code (16) in the F-Link software (or a bar code reader). Enter all digits located below the bar code (1400-00-0000-0001). − If you want to remove the detector from the system, erase it from its position in the control panel. − In order to comply with the EN 50131-2-4 norm, the cover tab (4) must be secured with the supplied screw. Detector internal settings Settings can be set by F-Link software in the Devices tab. Use the Internal settings option on the detector’s position to open a dialog window where you can configure the settings (* default settings): PIR immunity level: Defines false alarm immunity. The *Standard level combines basic immunity with a rapid reaction. The Increased level provides higher immunity but the detector reaction is slower. LQ photo quality: Standard* quality uses optimized compression in order to achieve the fastest possible transfer to the ARC or to the end user in MyJABLOTRON. The goal is achieving alarm verification in the fastest time possible. If the quality is switched to Extended, the system will use lower image compression which will at least double the time necessary to transfer the image (depends on the conditions of the captured scene). Change the quality only if the LQ image does not have the quality required by the customer – it may depend on the captured space. It is not recommended when there are more verification detectors in the premises which may take images at the same time. Taking photos during alarms: No flash, *With flash Flash intensity: Low, *Medium, High – if the captured scene is over- exposed (e.g.in a small room), the intensity of the flash can be decreased. It can be increased for larger spaces. Lithium battery operation: If the detector is tasked with frequent operation (e.g. frequently requested photos by MyJABLOTRON) and is configured to high flash intensity, we recommend the use of AA 1.5 V lithium batteries. If you operate the detector from lithium batteries, this parameter must be enabled (it adjusts detection of low batteries). PG output reaction: You can select PG outputs, whose activation will trigger taking a picture (* No, camera does not react to PG). For further info see Installation recommendations, cautions. Taking a photo by PG activation: No flash, *With flash Taking photos during entrance delay: *No flash, With flash Increased number of photos during alarm: When enabled, 3 photos are sent instead of 2 during each alarm event, that means more data transfer between the detector and the control panel and between the control panel and MyJABLOTRON or ARC. This option is for specific markets so we don’t recommend enabling by default. Send pre-alarm photos: This option is not available when the Extended LQ photo quality is selected due to more than double size of the photo and therefore longer transmission time. When this parameter is enabled the detector will send photos even when the detector is configured with repeated or confirmed reaction and the alarm has not been confirmed. During every entrance delay, up to two photos can be taken when the detector is triggered even when the system has been unset properly. This option will noticeably increase the volume of data transferred to MyJABLOTRON. If the system is not unset (alarm is triggered), the images taken during the entrance delay will be sent automatically regardless this option. Test: takes a test photo (LQ) with a flash and F-Link displays it. When the Detail button is pressed, the F-Link software shows the picture in a 640x480 px resolution. Photos are sent to MyJABLOTRON (provided that transferring is enabled). Camera and basic reactions The process of how the camera takes pictures depends on the settings in the F-Link software – the Devices tab. Choose a type of Reaction on the detector’s position. Instant: During an alarm triggered by the detector, the camera can be activated up to 3 times (then it will be auto-bypassed). Each activation, depending on the detected movement and settings, takes 3 photos maximum. Photos are sent to the control panel (9 photos maximum). Delayed: The first activation (entrance delay) takes up to 2 photos according to the detected movement and saves them into the internal memory (Send pre-alarm image disabled). When alarm is triggered, photos

jablotron JA-160PC: Security Sensors Category Related Instructions

SE-SRT Series
Datasensor SE-SRT Series
04.09.2026 11 pages

ACCESSORIES FOR SAFETY DEVICES - SE-DM: series: deviating mirrors - SE-LP: series: laser pointer - SE-S: series: floor stand - SE-SR2 series: safety relay - SE-SRT series: connection box Quick reference guide for the Datasensor SE-SRT Series Security Sensors. It outlines installation and user preferences, operation, user settings.

ULTRATEST UL3000 Fab
Inficon ULTRATEST UL3000 Fab
01.07.2026 140 pages

Translation of the original operating instructions UL3000 Fab, UL3000 Fab PLUS Helium Leak Detector with ULTRATEST ™ Sensor Technology iina73en1-08-(1910) Catalog No. 550-200, 550-250 From software version 1.41 Installation instructions for the Inficon ULTRATEST UL3000 Fab Security Sensors. It provides detailed operation instructions and testing procedures, product handling, error codes, installation support.

RAD7
DURRIDGE RAD7
21.06.2026 4 pages

RAD7 Bluetooth Connectivity Guide Configuring and using the SD1000 Serial to Bluetooth Adaptor Revision 1.0.8 2018-11-30 Introduction The Parani SD1000 Serial to Bluetooth Adaptor can facilitate the transmission of radon data between a DURRIDGE RAD7 radon mon Complete usage guide for the DURRIDGE RAD7 Laboratory Equipment. This guide explains technical procedures for startup procedures, daily usage, software installation, performance guidelines.

44-110
Ludlum Measurements 44-110
09.08.2026 16 pages

LUDLUM MODEL 44-110 & 44-110-1 LARGE AREA TRITIUM DETECTORS March 2013 Operation guide for the Ludlum Measurements 44-110 Security Sensors. The document contains user preferences, installation support, technical troubleshooting.