Service manual [PDF] (23 pages)
- Updated: 05.04.2026
Document Preview & Text Transcription
Surround Cinema
SUB200
Amplifier/Subwoofer
SERVICE MANUAL
JBL Consumer Products
250 Crossways Park Dr.
Woodbury, New York 11797
Rev0 9/2004
Note: The SUB200 is part of the SCS200.7 system
Satellite loudspeakers SCS200SAT order JBL part# SCS200SAT-1
Center channel SCS200CEN order JBL part# SCS200/300CEN-1
- CONTENTS -
BASIC SPECIFICATIONS……………….….….….….…………….1
DETAILED SPECIFICATIONS ……..…………….……………..2
OPERATION ………….……………………………..…………….4
CONNECTIONS..………………………..………….…….………...5
BASIC TROUBLESHOOTING…..…………….….….…….……...7
TEST SET-UP AND PROCEDURE……..……….…….………….8
EXPLODED VIEW/PARTS LIST…………………………………..9
BLOCK DIAGRAM..…………………………………………….....10
PCB DRAWINGS………………..………………………………...11
ELECTRICAL PARTS LIST ……………………….……………..15
INTEGRATED CIRCUIT/TRANSISTOR PINOUTS………….19
SCHEMATICS.………..…………………………………. ………20
PACKAGING…………………………….………………………...22
BASIC SPECIFICATIONS
SUB200 Subwoofer
Configuration:
Floor-firing, bass-reflex ported enclosure
Woofer:
8" (203mm) cone
Amplifier Power output:
100W Continuous RMS power
Frequency response:
35Hz – 160Hz (-6dB)
Dimensions (including feet):
16 1⁄4 x 11 x 13 3⁄4” (413 x 279 x 349mm)
Weight:
28 lb/12.7kg
Occasional refinements may be made to existing products without notice but will always meet or exceed original
specifications unless otherwise stated
SUB200 (SCS200.7sys)
1
JBL SUB200 100W Powered Sub/ Plate Amp
LINE VOLTAGE
Yes/No
Hi/Lo Line
Unit
Notes
US 120VAC/60Hz
Yes
108-132
Vrms
Normal Operation
Asia 100VAC/50Hz
Yes
90-110
Vrms
Normal Operation
EU 230VAC/50-60Hz
Yes
207-264
Vrms
Normal Operation
Normal operation, MOMS required
Parameter
Specification
Unit
QA Test
Limits
Conditions
Notes
Amp Section
Type (Class AB, D, other)
AB
AB
N/A
120V System is Class AB
Type (Class AB, D, other)
H
H
N/A
230V System is Class H
Load Impedance (speaker)
4
Ohms
N/A
Nominal
Rated Output Power 120V
100
Watts
85
@ Nominal input voltage
Different output power due to differences
in amp configuration between 120V and
230V
Rated Output Power 230V
105
Watts
100
@ Nominal input voltage
THD@ Rated Power
0.5
%
1
22K filter
THD @ 1 Watt
0.1
%
0.3
22K filter
DC Offset
10
mV-DC
50
@ Speaker Output
Damping factor
>100
DF
50
Measured at speaker terminals, Output
power 90 Watts THD 0.1 %
Input Sensitivity
Input Frequency
50
Hz
50
Nominal Freq.
Line Input (L&R)
15
mVrms
±2dB
To 1 Watt
1 input driven
LFE Input
9.5
mVrms
±2dB
To 1 Watt
LFE input driven only
Speaker/Hi Level Input
245
mVrms
±2dB
To 1 Watt
(-20 dB below Line In)...1 input driven
Signal to Noise
SNR-A-Weighted
90
dBA
85
To Rated power
A-Weighting filter
SNR-unweighted
80
dBr
80
To Rated power
22KHz filter
SNR @ 1W-unweighted
65
dBr
60
To 1 Watt
22KHz filter
Residual Noise Floor
1.5
mVrms
2.5
Volume @max, using RMS reading
DMM/VOM (or A/P)
Residual Noise Floor
1
mVrms(max)
2
Volume @max, w/ A/P Swept
Bandpass Measurement (Line freq.+
harmonics)
Input Impedance
Line input L&R , LFE
>10
K ohms
N/A
Nominal over the audio BW
Reference only
Speaker/Hi Level Input
4.7
K ohms
N/A
Nominal over the audio BW
Reference only
Filters
Low Pass (fixed or variable)
fixed
--
±2dB
Slope & Q
dB/Octave
N/A
Subsonic filter (HPF)
Hz
±2dB
Slope & Q
dB/Octave
N/A
Limiter (yes/no)
YES
--
N/A
THD at Max. Output Power
N/A
--
N/A
Features
LFE Input
YES
Functional
BW Limited to 500 Hz, refer to
ECR00031 & AP Curves
Volume pot Taper (lin/log)
LOG
--
Functional
ATO
YES
Functional
Input Configuration
Line In (L,R)
L ,R
--
Functional
RCA inputs: L , R Summed to Mono
Line level in LFE
LFE
Functional
Spkr/Hi Level In (L,R)
L,R
--
Functional
L R Summed to Mono
Spkr Out: Level out (L,R)Hi P
L,R
Functional
Direct by pass from Speaker in
Signal Sensing (ATO)
Auto-Turn-On (yes/no)
YES
--
Functional
ATO Input Frequency
50
Hz
Functional
ATO Level Line Level in (L,R
2
mV
Functional
2mV@50Hz into Line Input w/ 1 ch.
driven
ATO Level Speaker in
40
mV
Functional
SUB200 (SCS200.7sys)
2
Parameter
Specification
Unit
QA Test
Limits
Conditions
Notes
ATO Turn-on time
5
ms
Functional
Amp connected and AC on, then input
signal applied
Auto Mute/ Turn-OFF Time
15
minutes
Functional
T before muting, after signal is
removed
Auto turn of time (T) must be 10 > T <15
Power on Delay time
3
sec.
Functional
AC Power Applied
Transients/Pops
ATO Transient
5
mV-peak
10
@ Speaker Outputs
Turn-on Transient
50
mV-peak
100
@ Speaker Outputs
AC Line cycled from OFF to ON
Turn-off Transient
50
mV-peak
100
@ Speaker Outputs
AC Line cycled from ON to OFF
Efficiency
Stand-by Input Power
12
Watts
13
@ nom. line voltage
Maximum allowable input power under
nominal Input voltage and frequency,
HOT or COLD operation.
Power Cons.@rated power
180
Watts
187
@ 120V-60 Hz (Nom.line voltage)
90 Watts @ 4 Ohms nominal line voltage
Power Cons.@rated power
195
Watts
200
@ 230V-50 Hz (Nom.line voltage)
90 Watts @ 4 Ohms nominal line voltage
Protection
Short Circuit Protection
YES
--
Functional
Direct short at output
Thermal Protection
65 deg. C
--
Functional
@1/8 max unclipped Power
Temperature rise should not exceed 35K
rise
DC Offset Protection
YES
--
Functional
DC present at Speaker Out leads
Relay or crowbar (for driver/fire
Line Fuse Rating
120VAC
2.5
Amps
Type-T or Slo Blo
External fuse with UL/SEMKO rated
holder
230VAC
1.25
Amps
Type-T or Slo Blo
External fuse with UL/SEMKO rated
holder
SUB200 (SCS200.7sys)
3
Pages Preview: