Johnson Controls TEC2245-4 Manuals

1 pdf manual(s) Johnson Controls TEC2245-4 for free download (Document Types: Installation instructions manual)

Johnson Controls TEC2245-4 Installation instructions manual Thumbnail

Johnson Controls TEC2245-4 Installation instructions manual [PDF] (15 pages)

  • Identifier: id-1489719
  • Brand: Johnson Controls
  • Device: Johnson Controls TEC2245-4 Controller
  • Type: Installation instructions manual, PDF
  • Key Aspects: Additional Modules and Accessories Guide, Initial Startup Checklist, Regulatory Compliance and Standards
  • UPD Date: 26.05.2026
  • Source File: 1508710.pdf
  • Pages: 15
  • Description: Official operating instructions for the Johnson Controls TEC2245-4.
Pages Preview:
  • Johnson Controls TEC2245-4 Installation instructions manual preview - page 2
  • Johnson Controls TEC2245-4 Installation instructions manual preview - page 3
  • Johnson Controls TEC2245-4 Installation instructions manual preview - page 4
  • Johnson Controls TEC2245-4 Installation instructions manual preview - page 5
  • Johnson Controls TEC2245-4 Installation instructions manual preview - page 6
  • Johnson Controls TEC2245-4 Installation instructions manual preview - page 7
  • Johnson Controls TEC2245-4 Installation instructions manual preview - page 8
  • Johnson Controls TEC2245-4 Installation instructions manual preview - page 9
Document Preview & Text Transcription (Main Page)
Click to expand and read text
TEC2245-4 LONWORKS® Network Thermostat Controller with Single Proportional Output and One-Speed Fan Control Installation Instructions 1 Applications The TEC2245-4 Thermostat Controller is a LONWORKS® network device that provides control of two-pipe fan coils, cabinet unit heaters, or other equipment using a proportional 0 to 10 VDC control input and one-speed fan control. The technologically advanced TEC2245-4 Thermostat Controller features a Building Automation System (BAS) LONWORKS network communication capability that enables remote monitoring and programming for efficient space temperature control. The TEC2245-4 Thermostat Controller features an intuitive User Interface (UI) with backlit display that makes setup and operation quick and easy. The thermostat controller also employs a unique, proportional control algorithm that virtually eliminates temperature offset associated with traditional, differential-based thermostat controllers. North American Emissions Compliance United States Canada Installation Location Considerations Locate the TEC2245-4 Thermostat Controller: • on a partitioning wall, approximately 5 ft (1.5 m) above the floor in a location of average temperature • away from direct sunlight, radiant heat, outside walls, behind doors, air discharge grills, stairwells, or outside doors • away from steam or water pipes, warm air stacks, unconditioned areas (not heated or cooled), or sources of electrical interference Note: Allow for vertical air circulation to the TEC2245-4 Thermostat Controller. IMPORTANT: The TEC2245-4 Thermostat Controller is intended to provide an input to equipment under normal operating conditions. Where failure or malfunction of the thermostat controller could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction of the thermostat controller. This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense. This Class (A) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la Classe (A) respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. TEC2245-4 LONWORKS® Network Thermostat Controller with Single Proportional Output and One-Speed Fan Control Installation Instructions Part No. 24-9890-1257, Rev. — Issued February 8, 2010

Similar Manuals in the Controller Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
IDEC microsmart pentra

IDEC microsmart pentra Manual (Programming manual), @977A71

344 778 141 03-08-2026 view all manuals
Algo 8063

Algo 8063 Manual (Operation & user’s manual), @1WBEEF

35 1474 354 13-03-2026 view all manuals
Quickie DX2-REM420

Quickie DX2-REM420 Manual (Operation & user’s manual), @T49P6V

60 1469 338 20-05-2026 view all manuals
WAGO 750 Series

750 Series (I/O Systems ePDF User Manual, #1E6Z7T)

30 240 36 09-06-2026 view all manuals
GeoBox G408

Controller #NFLF1N

44 1162 221 05-04-2026 view all manuals
Siemens RVD230

Siemens RVD230 Manual (Basic documentation), @81O1CC

130 488 98 28-06-2026 view all manuals