Jung FMDW360WW Manuals

1 pdf manual(s) Jung FMDW360WW for free download (Document Types: Operating instructions manual)

Document Preview & Text Transcription

eNet motion detector eNet motion detector Art. no.: FMDW360WW Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully. The radio communication takes place via a non-exclusively available transmission path, and is therefore not suitable for safety-related applications, such as emergency stop and emergency call. These instructions are an integral part of the product, and must remain with the end customer. 2 Battery safety instructions This device or its accessories are supplied with batteries in the form of alkaline batteries LR03. DANGER! Batteries can be swallowed. This can lead directly to death by suffocation. Keep new and used batteries away from children. Do not use devices if the battery compartment does not close securely and keep away from children. If you suspect that a battery has been swallowed or is in any orifice of the body, seek immediate medical attention. WARNING! Improper handling of batteries can result in explosion, fire or chemical burn due to leakage. Do not heat or throw batteries into fire. Do not reverse polarity, short-circuit or recharge batteries. Do not deform or disassemble batteries. Replace batteries only with an identical or equivalent type. Remove empty batteries immediately and dispose of in an environmentally friendly manner. Exchange all batteries at the same time. Only use batteries of the same type and manufacturer. Do not combine old and new batteries. 3 Intended use – Automatic switching of lighting depending on the heat motion and ambient brightness – Operation only with radio actuators for switching and dimming from the eNet system – Ceiling mounting, surface-mounted, in dry interiors 4 Function Product characteristics – LED for signalling – Battery-powered device – Brightness threshold settable – Run-on time adjustable – Sensitivity can be set Can be set with eNet server: – Disabling of manual commissioning – Longer run-on time adjustable – Brightness threshold settable – Power saving level 1 / 12 82598403 25.07.2019 J0082598403 eNet motion detector – Transmission behaviour Supplementary functions with eNet Server – Fully encrypted radio transmission (AES-CCM) – Operation with eNet server from version 2.2 – Update of the device software – Reading of error memory Automatic operation The device detects heat motions of people, animals and objects. – The light is switched on via a connected actuator if a person enters the detection field and the brightness threshold is below the set brightness threshold. – The run-on time restarts with each detected motion. – The light is switched off if no more movement is detected in the detection field and the run-on time in the actuator has elapsed. Limiting the switch-on time If the parameter “Manual switch-off of run-on time” is switched off in the actuator, the light is switched off after 90 minutes at the latest. This is also the case when there is constant motion in the detection field. The light is only switched on again if the brightness drops below the threshold and motions are detected. If the parameter “Manual switch-off of the run-on time” is activated in the actuator, there is no limitation. Display of battery status After transmission, the status LED (4) (Figure 4) flashes slowly after 3 seconds. The batteries are almost empty and should be replaced (see chapter “Inserting batteries”). 5 Operation For manual operation, a radio hand transmitter, for example, must be connected to the radio ac- tuator in addition to the ceiling detector. The parameter “Manual switch-off of run-on time” is switched off in the actuator (factory setting). The radio transmitter can be used to make the following settings: – The actuator can be switched on independently of the brightness for the run-on time saved in the actuator. – The run-on time saved in the actuator can be restarted. – The display brightness can be set in combination with a dimming actuator. As long as the sensor detects a movement in the detection field, the actuator remains switched on. The actuator cannot be switched off. The parameter “Manual switch-off of the run-on time” is activated with the eNet Server. The radio transmitter can be used to make the following settings: – The actuator can be switched on independently of the brightness for the run-on time saved in the actuator. – The run-on time saved in the actuator can be restarted. – The display brightness can be set in combination with a dimming actuator. As long as the sensor detects a movement in the detection field, the actuator remains switched on. – The actuator can be switched off. If the actuator was switched off manually, automatic switching on of the sensor is locked for 3 minutes. Any motions that are detected extend the time. Manual switching on via the radio transmitter is possible at any time. 2 / 12 82598403 25.07.2019 J0082598403 eNet motion detector 6 Information for electrically skilled persons Selecting installation location The sensor is installed on the ceiling and monitors the surface below. The sensor has a detec- tion area of 360° and is more sensitive in the central area than in the peripheral area. The detection of heat sources by a motion detector and thus the extent of the detection field is influenced by the following criteria: Mounting height, sensitivity setting and direction of move- ment. Tangential movements can be detected better than radial movements. The range is therefore greater for tangential movements than for radial movements. The specifications on the extent of the detection field are general guide values. Discrep- ancies can occur depending on the installation environment and the intensity of the heat motion. Figure 1: Detection field 1: Range for tangential movement on the ground is approx. Ø 8 m (Figure 1) 2: Range for radial movement on the ground is approx. Ø 5 m (Figure 1) These specifications refer to mounting on the ceiling at a mounting height of 2.5 m. The detec- tion field becomes larger for mounting heights above 2.5 m, while the detection density and sensitivity are reduced at the same time. ■ Select a vibration-free installation location. Vibrations can lead to unwanted switching. ■ Avoid interference sources in the detection area. Interference sources can trigger the mo- tion detector, e.g. heat sources such as heating units, outlets from ventilation openings or air conditioners, copiers, printers, coffee machines, draughty doorways, animals etc. The detection field can be limited in order to minimise the influence of interference sources. For this, use the push-on cover (see “Limiting the detection field using the push- on cover”). Fitting the device Figure 2: Disconnect sensor from base plate 3 / 12 82598403 25.07.2019 J0082598403 eNet motion detector Figure 3: Fasten the base plate ■ Pay attention to correct alignment of the base plate already during mounting. ■ Align the device so that the brightness sensor (3) (Figure 4) is on the side away from the windows. This reduces the effects of scattered light. ■ Pull off decor ring (2) (Figure 2). ■ Turn the sensor by approx. 45° in the OPEN direction to disconnect it from the base plate (Figure 2). ■ Fasten the base plate to the ceiling using screws (1). ■ Perform commissioning. Expanding the detection field To expand the detection field, multiple motion detectors can be connected to one actuator. The devices work independently of each other. Sensitivity, brightness threshold and run-on time are set for each device. When motion is detected, each motion detector sends a telegram to the ac- tuator. The actuator evaluates the telegrams of the individual motion detectors and switches the load accordingly. The longest run-on time sent is always executed. 7 Commissioning DANGER! Mortal danger of electric shock. During commissioning, cover the parts carrying voltage on radio transmitters and ac- tuators and in their surrounding area. Notes on commissioning – The sensor can also be commissioned with eNet Server as an alternative to the commis- sioning described here. – The adjusters (5-7) are located behind the decorative ring (2). – The light guide (3) for brightness detection is also the Test/Prog. button – The status LED (4) is located behind the lens 4 / 12 82598403 25.07.2019 J0082598403