Kobold RFS Manuals

2 pdf manual(s) Kobold RFS for free download (Document Types: Operating instructions manual)

Document Preview & Text Transcription

Operating Instructions for Level Switch for Liquids Model: RFS RFS page 2 RFS K02/0118 1. Contents 1.  Contents ........................................................................................................ 2 2.  Note .............................................................................................................. 3 3.  Instrument Inspection .................................................................................... 3 4.  Regulation Use .............................................................................................. 3 5.  Operating Principle ........................................................................................ 4 6.  Use in Hazardous Areas ............................................................................... 4 7.  Mechanical Connection ................................................................................. 5 8.  Electrical Connection .................................................................................... 6 9.  Technical Information .................................................................................... 8 10. Order Codes ................................................................................................. 9 11. Dimensions ................................................................................................. 10 12. EU Declaration of Conformance .................................................................. 11 13. ATEX-Certificate ......................................................................................... 12 Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: +49(0)6192-2990 Fax: +49(0)6192-23398 E-Mail: [email protected] Internet: www.kobold.com RFS RFS K02/0118 page 3 2. Note Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health & Safety and prevention of accidents. When used in machines, the measuring unit should be used only when the machines fulfil the EC-machine guidelines. 3. Instrument Inspection Instruments are inspected before shipping and sent out in perfect condition. Should damage to a device be visible, we recommend a thorough inspection of the delivery packaging. In case of damage, please inform your parcel service / forwarding agent immediately, since they are responsible for damages during transit. Scope of delivery: The standard delivery includes:  Level Switch model: RFS  Operating Instructions 4. Regulation Use Model RFS devices are used for when monitoring liquid levels. The device should only be used with liquids that are compatible with the unit’s materials of construction. Level control is often accomplished with at least two level switches - one acting to sense the minimum level and the other for maximum level detection. Any use of the Level Switch, model: RFS, which exceeds the manufacturer’s specification, may invalidate its warranty. Therefore, any resulting damage is not the responsibility of the manufacturer. The user assumes all risk for such usage. RFS page 4 RFS K02/0118 5. Operating Principle The Level Switch RFS is designed for economical control of liquids in vessels. The following three versions are available: A device with plug connection and two devices with aluminium housing connection of which one is an ATEX-version for the use in environment with gas explosion hazards. The switch is remarkable for its maintenance-free design and small dimensions. The switch is mounted on the side of the vessel. A hinged stainless steel float with a magnet floats up and down through the liquid level. In the end position a potential-free reed contact is operated by the magnet. The switching function (N/O contact / N/C contact) is determined by the mounting position. The switching function is reserved by simply rotating the switch through 180°. 6. Use in Hazardous Areas With the approval the Level Switch, model RFS, can be used within hazardous areas. Thereby the aluminium housing is applicable outside the process in zone of category 2D. The float is appropriate for the use within the process in zone of category 2D and 1D. The approvals are as follows: II 1 GD Ex ia IIC T6 Ga -20≤Ta≤+60 °C An additional intrinsically safe relay is required in environment with gas explosion hazards (KFA…and respectively KFD). For a correct and professional potential equalization, the ground terminal on the housing of the RFS must be connected in applications in hazardous areas.

Document Preview & Text Transcription

Operating Instructions For Magnetic level switch RFS RFS Page 2 DT0649 1. Content 1.  Content ......................................................................................................... 2 2.  Note .............................................................................................................. 3 3.  Instrument Inspection .................................................................................... 3 4.  Description .................................................................................................... 3 5.  Operation ...................................................................................................... 4 6.  Use in Hazardous Areas ............................................................................... 4 7.  Mechanical Connection ................................................................................. 5 8.  Electrical Connection .................................................................................... 6 9.  Models .......................................................................................................... 8 10. Technical data ............................................................................................... 9 11. Safety Instructions ( ATEX ) ........................................................................ 11 12. Installation in ATEX areas ........................................................................... 12 13. Electrical connection in ATEX area ............................................................. 13 14. Label description (ATEX) ............................................................................ 13 15. EU Declaration of conformity (ATEX) .......................................................... 14 16. EU Declaration of conformity ...................................................................... 15 17. UK Declaration of conformity ...................................................................... 16 18. ATEX Certified ............................................................................................ 17 19. Notes ........................................................................................................... 17 Manufactured by: Kobold Mesura S.L.U Av. Conflent Nº68 Nave 15 08915 Badalona Tel.: +34 93 460 38 83 Fax: +34 93 460 38 72 E-Mail: [email protected] Internet: www.kobold.com Edition: May 2022 RFS DT0649 Page 3 2. Note Please read these operating instructions before unpacking and putting the unit in operation. Follow the instructions precisely as described herein. The instruction manuals on our website www.kobold.com are always for currently manufactured version of our products. Due to technical changes, the instruction manuals available online may not always correspond to the product version you have purchased. If you need an instruction manual that correspond to the purchased product version, you can request it from us free of charge by email ([email protected]) in PDF format, specifying the relevant invoice number and serial number. If you wish, the operating instructions can also be sent to you by post in paper form against an applicable postage fee. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health & Safety and prevention of accidents. When used in machines, the measuring unit should be used only when the machines fulfil the EC-machine guidelines. 3. Instrument Inspection Instruments are inspected before shipping and sent out in perfect condition. Should damage to a device be visible, we recommend a thorough inspection of the delivery packaging. In case of damage, please inform your parcel service / forwarding agent immediately, since they are responsible for damages during transit. Scope of delivery The Standard delivery includes:  Magnetic Level switch RFS  Operating instructions 4. Description Model RFS devices are used for monitoring liquid levels. The device should only be used with liquids that are compatible with the unit´s materials of construction. The standard version can be mounted in a wide range of installations while the ATEX version is to be mounted in classified installations category 1 requiring certification 1G Ex ia IIC T6, 1D Ex ia IIIC T85ºC Da.