Kohler K-682 Manuals

3 pdf manual(s) Kohler K-682 for free download (Document Types: Homeowner's manual, Installation manual)

Document Preview & Text Transcription

Homeowners Guide Six-Port Thermostatic Valve M product numbers are for Mexico (i.e. K-12345M) Los números de productos seguidos de M corresponden a México (Ej. K-12345M) Français, page “Français-1” Español, página “Español-1” K-682 1043183-5-B Important Information WARNING: When using electrical products, basic precautions should always be followed, including the following: DANGER: Risk of electric shock. Grounding is required. Connect only to circuits protected by a Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage Circuit Breaker (ELCB). WARNING: Risk of electric shock. The unit should be installed by a qualified service representative and a licensed electrician should route all electrical wiring. WARNING: Risk of electric shock. Disconnect power before servicing. WARNING: Unauthorized modification may cause poor performance of the valve. Do not make modifications to the valve as this could adversely affect the performance of the valve and void the warranty. Kohler Co. shall not be liable under its warranty or otherwise for personal injury or damage caused by any such unauthorized modification. WARNING: Risk of injury or property damage. Please read all instructions thoroughly before beginning installation. NOTICE: Follow all plumbing, electrical and building codes. NOTICE: Provide generous, unrestricted service access to the valve. Provide access for servicing the valve and interface. This access must be located immediately next to the valve. Refer to the roughing in information. Specifications Pressures Maximum Static Pressure 125 psi, 862 kPa, 8.6 bar Supply Pressure Differential* Max 5 psi, 34.5 kPa, 0.34 bar (Equal pressures recommended.) Minimum Flow Rate 1.6 gpm (Less than 72 psi dynamic pressure.) 6 lpm (Less than 500 kPa maintaining pressure.) 2.1 gpm (Greater than 72 psi dynamic pressure.) 8 lpm (Greater than 500 kPa maintaining pressure.) Temperatures Programmable Temperature Max 120°F (49°C) Min 79°F (26°C) Full cold may also be selected. Default Temperature at Start-up 102°F (39°C) Minimum Mixed Temperature Differential from Hot Supply 3.6°F (2°C) Optimum Thermostatic Control Range 86°F (30°C) to 120°F (49°C) Temperature Stability at Recommended Supply Conditions +/- 1.6°F (1°C) Ambient Temperature Greater than 34°F (1°C), Max 104°F (40°C) Maximum Relative Humidity 95% non-condensing Electrical Electrical Service 100-240 VAC, 50-60 Hz, 1.5 A User Interface Cable Length (supplied) 30 ft (9.14 m) * In commercial applications where there is a large difference in hot and cold supply pressures or frequent fluctuation in either supply line is anticipated, it is strongly recommended that pressure regulators be installed. Thank You For Choosing Kohler Company Thank you for choosing the Bold Look of Kohler. Kohler craftsmanship offers you a rare combination of proven performance and graceful sophistication that will satisfy you for years to come. The dependability and beauty of your Kohler product will surpass your highest expectations. We’re very proud of our products here at Kohler and we know you will be too. Please take a few minutes to study this Homeowners Guide. Pay special attention to the care and cleaning instructions. 1043183-5-B 2 Kohler Co. Thank You For Choosing Kohler Company (cont.) All information in this manual is based upon the latest product information available at the time of publication. At Kohler, we constantly strive to improve the quality of our products. We reserve the right to make changes in product characteristics, packaging or availability at any time without notice. Limited Five-Year Warranty For North America Only Kohler Co. warrants that its electronic faucets, valves and controls will be free of defects in material and workmanship during normal residential use for five years from the date the product is installed. This warranty applies only to electronic faucets, valves and controls installed in the United States of America and Canada. If a defect is found in normal residential use, Kohler Co. will, at its election, repair, provide a replacement part or product, or make appropriate adjustment. Damage caused by accident, misuse, or abuse is not covered by this warranty. Improper care and cleaning will void the warranty*. Proof of purchase (original sales receipt) must be provided to Kohler Co. with all warranty claims. Kohler Co. is not responsible for labor charges, installation, or other incidental or consequential costs other than those noted above. In no event shall the liability of Kohler Co. exceed the purchase price of the faucet, valve or control. If the electronic faucets, valves or controls are used commercially or are installed outside of North America, Kohler Co. warrants that the faucet, valve or control will be free from defects in material and workmanship for one (1) year from the date the product is installed, with all other terms of this warranty applying except duration. If you believe that you have a warranty claim, contact your Home Center, Dealer, Plumbing Contractor or E-tailer. Please be sure to provide all pertinent information regarding your claim, including a complete description of the problem, the product, model number, the date the product was purchased, from whom the product was purchased and the installation date. Also include your original invoice. For other information, or to obtain the name and address of the service and repair facility nearest you, write Kohler Co., Attn: PNA Customer Service, Kohler, Wisconsin 53044 USA or call 1-800-4-KOHLER from within the USA and 1-800-964-5590 from within Canada. The foregoing warranties are in lieu of all other warranties, express or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Kohler Co. and/or seller disclaim any liability for special, incidental or consequential damages. Some states/provinces do not allow limitations of how long an implied warranty lasts or the exclusion or limitation of such damages, so these limitations and exclusions may not apply to you. This warranty gives the consumer specific legal rights. You may also have other rights that vary from state/province to state/province. This warranty is to the original consumer purchaser only, and excludes product damage due to installation error, product abuse, or product misuse, whether performed by a contractor, service company, or the consumer. This is Kohler Co.’s exclusive written warranty. *Never use cleaners containing abrasive cleansers, ammonia, bleach, acids, waxes, alcohol, solvents or other products not recommended for chrome. This will void the warranty. One-Year Warranty For Mexico Only KOHLER CO. It is recommended that at the time of purchase, you verify that all accessories and components are complete in this package. This Kohler product is warranted to be free of defects in material and workmanship for one (1) year from the date of purchase as shown on the invoice or receipt. 1. Kohler Co. will only service its commercialized products through its authorized distributors. Kohler Co. 3 1043183-5-B One-Year Warranty (cont.) 2. To obtain warranty service, please present the invoice and corresponding warranty. 3. Through its authorized distributors, Kohler Co. promises to repair the defective product or provide a new replacement or an equivalent model (in those cases that the model has been discontinued) when the product is beyond repair, without any charge to the consumer. 4. The time of repair will not exceed six (6) weeks commencing on the date the product is received. 5. It is recommended that the consumer save the invoice or receipt as additional protection, as it may substitute the warranty in the case that there is a discrepancy in the validity of the warranty. EXCEPTIONS AND RESTRICTIONS The Warranty will not be valid in the following cases: 1. When the product is not operated in accordance with the instructions concerning use and operation set forth in the owner’s manual or installation instructions, and when the recommendations and warnings included are not observed. 2. When the product has been modified or dismantled partially or totally; or has been used in a negligent fashion and as a consequence has suffered damages attributable to the consumer, individual, or hardware not authorized by Kohler Co. 3. This warranty does not cover the damages as a result of disaster such as fire or acts of God, including flooding, earthquake, or electric storms, etc. To obtain a list of distributors in your area where you can exercise your rights under this warranty, please call 001-877-680-1310. KOHLER CO., KOHLER, WI 53044 U.S.A. IMPORTER: INTERNACIONAL DE CERÁMICA, S.A. DE C.V. AV. CARLOS PACHECO NO. 7200 CHIHUAHUA, CHIH., MEXICO C.P. 31060 TEL: 52 (14) 29-11-11 Troubleshooting CAUTION: Risk of personal injury. The valve may contain hot water; be careful when draining any residual water. IMPORTANT! Turn off the power and water supply to the valve before performing any maintenance. It is recommended that any valve maintenance should be performed by an authorized Kohler service representative. This troubleshooting guide is for general aid only. For service and installation issues or concerns, call 1-800-4-KOHLER. Troubleshooting Table Symptoms Probable Cause Recommended Action 1. Control panel is not lit. A. Power supply is not plugged into the outlet. A. Plug the power supply into the outlet. B. Power supply connection to the valve may be loose or disconnected. B. Check power supply connections to the valve and reconnect if needed. C. Interface cable connections may be loose or disconnected. C. Check all interface cable connections, connect if needed. D. Circuit breaker has been tripped. D. Reset the circuit breaker. 1043183-5-B 4 Kohler Co.

Document Preview & Text Transcription

Homeowners Guide Six-Port Thermostatic Valve M product numbers are for Mexico (i.e. K-12345M) Los números de productos seguidos de M corresponden a México (Ej. K-12345M) Français, page “Français-1” Español, página “Español-1” K-682 1043183-5-E IMPORTANT INSTRUCTIONS WARNING: When using electrical products, basic precautions should always be followed, including the following: DANGER: Risk of electric shock. Grounding is required. Connect only to circuits protected by a Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). WARNING: Risk of electric shock. A qualified service representative and a licensed electrician must install this product and route all electrical wiring for the product. Improper installation will create an electrical hazard and may not comply with local building and electrical codes. WARNING: Risk of electric shock. Disconnect power before performing any maintenance. When disconnected, the product will no longer be electrically live, which will eliminate the risk of electric shock. WARNING: Risk of injury or property damage. Please read all instructions thoroughly before beginning installation. NOTICE: Follow all plumbing, electrical and building codes. NOTICE: Provide generous, unrestricted service access to the valve and interface. This access must be located immediately next to the valve. Refer to the roughing-in information. Specifications Pressures Maximum Static Pressure 125 psi, 862 kPa, 8.6 bar Supply Pressure Differential* Max 5 psi, 34.5 kPa, 0.34 bar (Equal pressures recommended.) Minimum Flow Rate 1.6 gal/min (Less than 72 psi dynamic pressure.) 6 l/min (Less than 500 kPa maintaining pressure.) 2.1 gal/min (Greater than 72 psi dynamic pressure.) 8 l/min (Greater than 500 kPa maintaining pressure.) Temperatures Programmable Temperature Max 120°F (49°C) Min 79°F (26°C) Full cold may also be selected. Default Temperature at Start-up 102°F (39°C) Minimum Mixed Temperature Differential from Hot Supply 3.6°F (2°C) Optimum Thermostatic Control Range 86°F (30°C) to 120°F (49°C) Temperature Stability at Recommended Supply Conditions +/- 1.6°F (1°C) Ambient Temperature Greater than 34°F (1°C), Max 104°F (40°C) Maximum Relative Humidity 95% non-condensing Electrical Electrical Service 100-240 VAC, 50-60 Hz, 1.5 A User Interface Cable Length (supplied) 30’ (9.14 m) * In commercial applications where there is a large difference in hot and cold supply pressures or frequent fluctuation in either supply line is anticipated, it is strongly recommended that pressure regulators be installed. Warranty KOHLER® Electronic Faucets, Valves and Controls FIVE-YEAR LIMITED WARRANTY Kohler Co. warrants that its electronic faucets, valves and controls will be free of defects in material and workmanship during normal residential use for five years from the date the product is installed. This 1043183-5-E 2 Kohler Co. Warranty (cont.) warranty applies only to electronic faucets, valves and controls installed in the United States of America, Canada and Mexico (″North America″). If a defect is found in normal residential use, Kohler Co. will, at its election, repair, provide a replacement part or product, or make appropriate adjustment where Kohler Co.’s inspection discloses any such defect. Damage caused by accident, misuse, or abuse is not covered by this warranty. Improper care and cleaning will void the warranty*. Proof of purchase (original sales receipt) must be provided to Kohler Co. with all warranty claims. Kohler Co. is not responsible for labor charges, installation, or other incidental or consequential costs other than those noted above. In no event shall the liability of Kohler Co. exceed the purchase price of the faucet, valve or control. If the electronic faucets, valves or controls are used commercially or are installed outside of North America, Kohler Co. warrants that the faucet, valve or control will be free from defects in material and workmanship for one (1) year from the date the product is installed, with all other terms of this warranty applying except duration. If you believe that you have a warranty claim, contact your Home Center, Dealer, Plumbing Contractor or E-tailer. Please be sure to provide all pertinent information regarding your claim, including a complete description of the problem, the product, model number, the date the product was purchased, from whom the product was purchased and the installation date. Also include your original invoice. For other information, or to obtain the name and address of the service and repair facility nearest you, write Kohler Co., Attn: Customer Care Center, Kohler, Wisconsin 53044 USA, or by calling 1-800-4-KOHLER (1-800-456-4537) from within the USA and Canada, and 001-800-456-4537 from within Mexico, or visit www.kohler.com within the USA, www.ca.kohler.com from within Canada, or www.mx.kohler.com in Mexico. THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KOHLER CO. AND/OR SELLER DISCLAIM ANY LIABILITY FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states/provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of such damages, so these limitations and exclusions may not apply to you. This warranty gives the consumer specific legal rights. You may also have other rights that vary from state/province to state/province. This warranty is to the original consumer purchaser only, and excludes product damage due to installation error, product abuse, or product misuse, whether performed by a contractor, service company, or the consumer. This is Kohler Co.’s exclusive written warranty. *Never use cleaners containing abrasive cleansers, ammonia, bleach, acids, waxes, alcohol, solvents or other products not recommended for chrome. This will void the warranty. Kohler Co. 3 1043183-5-E Clean the Inlet Screens Disconnect the power and turn off the water supply. Disconnect and remove the removable pipe segment. Using a screwdriver, remove the inlet clamp screws. Remove the inlet clamp. Remove the adapters from the valve inlets. Gently pull the check valves from the valve inlets. Remove the screens from the check valves. Clean the screens to remove any dirt or debris. Rinse or replace the check valves and screens. Reassemble the inlet connections. Troubleshooting WARNING: Risk of electric shock. Disconnect power before performing any maintenance. When disconnected, the product will no longer be electrically live, which will eliminate the risk of electric shock. CAUTION: Risk of personal injury. The valve may contain hot water; be careful when draining any residual water. NOTICE: Any valve maintenance should be performed by a Kohler Co. Authorized Service Representative. O-Ring Screw Screen Check Valve Adapter Union Connection Removable Pipe Segment Inlet Clamp 1043183-5-E 4 Kohler Co.

Document Preview & Text Transcription

Installation Guide Digital Thermostatic Valve K-682 M product numbers are for Mexico (i.e. K-12345M) Los números de productos seguidos de M corresponden a México (Ej. K-12345M) Français, page ″Français-1″ Español, página ″Español-1″ 1043183-2-E IMPORTANT INSTRUCTIONS WARNING: When using electrical products, basic precautions should always be followed, including the following: WARNING: Risk of electric shock. A qualified electrician should route all electrical wiring. WARNING: Risk of electric shock. Disconnect power before servicing. WARNING: Unauthorized modification may cause poor performance of the valve. Do not make modifications to the valve as this could adversely affect the performance of the valve and void the warranty. Kohler Co. shall not be liable under its warranty or otherwise for personal injury or damage caused by any such unauthorized modification. WARNING: Risk of injury or property damage. Please read all instructions thoroughly before beginning installation. NOTICE: Follow all plumbing, electrical, and building codes. NOTICE: Some electrical codes require a circuit protected by a Ground-Fault Circuit-Interrupter (GFCI)*. NOTICE: Provide unrestricted service access to the valve. *Outside North America, this device may be known as a Residual Current Device (RCD). ___________________________________________________________________________________________________ Operation with DTV, DTV II, or DTV+ DTV: The valve is controlled from one or two user interfaces that connect directly to the valve. DTV II: To connect the valve to the DTV II system, the K-638 media module is required. DTV+: To connect one or two valves to the DTV+ system, the K-99695 system controller and K-97172 data cable(s) are required. Refer to the appropriate sections in this guide for your system configuration. Specifications Pressures Maximum Static Pressure 125 psi, 862 kPa, 8.6 bar Supply Pressure Differential* Max 5 psi, 34.5 kPa, 0.34 bar differential Hot pressure should be equal to or less than cold pressure. Minimum Flow Rate 1.6 gal/min (Less than 72 psi dynamic pressure.) 6 l/min (Less than 500 kPa maintaining pressure.) 2.1 gal/min (Greater than 72 psi dynamic pressure.) 8 l/min (Greater than 500 kPa maintaining pressure.) Temperatures Programmable Temperature Max 120°F (49°C) Min 79°F (26°C) Full cold may also be selected. Default Temperature at Start-up 102°F (39°C) Minimum Mixed Temperature Differential from Hot Supply 3.6°F (2°C) Optimum Thermostatic Control Range 86°F (30°C) to 120°F (49°C) Temperature Stability at Recommended Supply Conditions +/- 1.6°F (1°C) Ambient Temperature Greater than 34°F (1°C), Max 104°F (40°C) Maximum Relative Humidity 95% non-condensing Electrical 1043183-2-E 2 Kohler Co. Specifications (cont.) Pressures Electrical Rating 100-240 VAC, 50-60 Hz, 1.5 A User Interface Cable Length (supplied) 30’ (9.14 m) *In commercial applications where there is a large difference in hot and cold supply pressures or frequent fluctuation in either supply line is anticipated, it is strongly recommended that pressure regulators be installed. Tools and Materials Plus: • (2) 3/4" and (6) 1/2" Union Connectors • Wood and Framing Materials • PEX Tubing or Copper Tubing • (2) Water Hammer Arrestors (Recommended) • (2) Supply Shut-Off Valves Solder Propane Torch Hacksaw or Tube Cutter Sealant Tape Kohler Co. 3 1043183-2-E Roughing-In Before You Begin NOTICE: Do not install the valve or power supply under a whirlpool surround or any location where the temperature may exceed 104°F (40°C). The power supply and valve are rated to operate in temperatures up to 104°F (40°C). NOTICE: Do not apply excessive heat near the valve or apply flux or acids directly onto the valve. This valve contains plastic and rubber components which will melt if heat is directly applied. NOTICE: Do not apply petroleum-based lubricants to the valve components. Doing so will damage the valve components. NOTICE: Do not use oil-based, non-setting compounds, such as plumbers putty, on the threaded inlet and outlet connections. Use sealant tape or liquid sealant. NOTICE: Do not allow any outlet to flow more than 10 gal/min (37.9 l/min). Read these instructions and determine the locations of all required components before beginning installation. When possible, install the valve before installing the other components. If possible, flush all piping thoroughly before installing the valve. If the pipes are flushed after the valve is installed, clean the inlet screens before using the system. A qualified electrician should install a 120 V electrical outlet, within the stud framing, in close proximity to the valve. A GFCI outlet may be required in certain applications. If possible, install the electrical outlet prior to installing the valve. 20-1/8" (511 mm) 21-5/16" (541 mm) 5-15/16" (151 mm) 30-7/8" (784 mm) 22-1/4" (565 mm) 1/2" NPT Outlets (6) 3/4" NPT Inlets Cold Hot 1-3/4" (44 mm) 1-3/4" (44 mm) 1-3/4" (44 mm) 1-3/4" (44 mm) 1-3/4" (44 mm) 3-1/16" (78 mm) 2-3/16" (56 mm) 1-5/16" (33 mm) 3-3/16" (81 mm) 2" (51 mm) 3" (76 mm) 7-3/8" (187 mm) 9-3/16" (233 mm) 2-1/8" (54 mm) 3-5/16" (84 mm) 13' - 1/8" (3968 mm) 1043183-2-E 4 Kohler Co.