Kusam-meco 603 Manuals

1 pdf manual(s) Kusam-meco 603 for free download (Document Types: Manual )

Kusam-meco 603 Manual  Thumbnail

Kusam-meco 603 Manual  [PDF] (15 pages)

  • Identifier: id-1588081
  • Brand: Kusam-meco
  • Device: Kusam-meco 603 Multimeter
  • Type: Manual , PDF
  • Key Aspects: User Training Recommendations, Control Panel and Interface Navigation, Hardware Setup Instructions
  • UPD Date: 06.03.2026
  • Source File: 1592633.pdf
  • Pages: 15
  • Description: Official installation manual for the Kusam-meco 603.
Pages Preview:
  • Kusam-meco 603 Manual  preview - page 2
  • Kusam-meco 603 Manual  preview - page 3
  • Kusam-meco 603 Manual  preview - page 4
  • Kusam-meco 603 Manual  preview - page 5
  • Kusam-meco 603 Manual  preview - page 6
  • Kusam-meco 603 Manual  preview - page 7
  • Kusam-meco 603 Manual  preview - page 8
  • Kusam-meco 603 Manual  preview - page 9
Document Preview & Text Transcription (Main Page)
Click to expand and read text
An ISO 9001:2008 Company ® G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct.: 022 -2 4156638, Tel. : 022-241224540, 24181649, Fax : 022 - 24149659 Email : [email protected], Website : www.kusamelectrical.com, An ISO 9001:2008 Company ® All Specifications are subject to change without prior notice Navin com/D:Sandeep Gupta/New Catlog Dec 2011/KM-603.cdr 3½ DIGIT 1999 COUNTS DIGITAL MULTIMETER 8 FUNCTIONS 30 RANGES Model 603 ELECTRICAL SPECIFICATIONS- 603 Accuracy : ± (% reading + digit) at 23 ± 5°C less than 75% RH. ±(1.5%rdg + 4dgts) 100 � V 1 mV 10 mV 1 V 100 mV 200 mV 2 V 20 V 750 V 200 V AC VOLTAGE Accuracy Resolution Range ±(1.0%rdg + 4dgts) Input Impedance : 10M� Overload Protection : 500V DC / 350V AC for 15 sec. on the 200mV range, 1200V DC / 800V AC on all other ranges DC VOLTAGE Accuracy ±(0.5%rdg + 1dgts) Resolution 100 � V 1 mV 10 mV 1 V 100 mV Range 200 mV 2 V 20 V 1000 V 200 V Input Impedance : 10M� Overload Protection : 500V DC / 350V AC for 15 sec.on the 200mV range, 1200V DC / 800V AC on all other ranges ±(1.0%rdg + 1dgt) ±(2.0%rdg + 3dgts) 100 nA 1 � A 10 � A 10 mA 100 � A 200 � A 2 mA 20 mA 10 A 200 mA Accuracy Resolution Range DC CURRENT Overload Protection : 10A Input fused upto 12A for 30 sec. Other range Input, 0.8A/250V Fuse. Voltage Burden : 10A range 700mV MAX. 100 nA 1 � A 10 � A 10 mA 100 � A 200 � A 2 mA 20 mA 10 A AC CURRENT 200 mA Accuracy Resolution Range ±(2.0%rdg + 4dgts) ±(1.2%rdg + 4dgts) Overload Protection : 10A Input fused upto 12A for 30 sec. Other range Input, 0.8A/250V Fuse. Voltage Burden : 10A range 700mV MAX. 200 � 2 K� 20 K� 200 K� 2000 K� 20 M� 200 M� 0.1 � 1 � 10 � 100 � 1 K� 10 K� 100 K� Accuracy Resolution Range RESISTANCE ±(5.0%rdg -10dgts) ±(3.0%rdg + 3dgts) ±(0.8%rdg + 1dgt) ±(1.0%rdg + 3dgts) Overload Protection : 500V DC/AC Test Voltage : 200 � range 3.2V MAX., 20M� range 3.0V MAX, 200M� range 3.2V MAX., Other range 3.0V MAX 0 to 1000 2.8V ± 0.4V 10 � A TRANSISTOR hFE TEST Range Vce Basic DC Current GENERAL SPECIFICATIONS : SPECIAL FEATURES : � High Accuracy, Digital Reading � Large LCD for easy reading � Automatic Zero adjustment. � Instant continuity buzzer � OverLoad Protection on all ranges � Recessed safety designed Input Jacks � Diode, Continuity Test & Transistor hFE Test. � Automatic -ve polarity indication ACCESSORIES : Test Leads, Spare Fuse, Carrying Case, User's Manual & Battery. � Sensing : Average Sensing. � Basic Accuracy : ±(0.5%rdg + 1dgt) � Display : 3½ digit Max. 1999 Counts Large LCD display � Display Size : 18 mm � Measurement Rate : 3 measurements per second nominal � Over range Indication : MSB (highest) digit (1) or (-1) is displayed. � Low battery : The “ ” sign is displayed when the battery voltage drops below the operating Voltage. � Operating Temperature : 0°C to +50°C; 70%R.H. � Storage Temperature : -20°C to 60°C; 0-80%R.H. (With Battery Removed) � Power : Single, Standard 9V battery. � Dimension : 170(L) x 80(W) x 40(H)mm � Weight : Approx. 250g (including battery) Test Current 1.0 ± 0.6mA 3.2V MAX. DIODE TEST Overload Protection : 500V DC or AC rms Test Voltage Less than 100� Audible Sound Buzzer CONTINUITY TEST Overload Protection : 500V DC or AC rms 10Amps RANGE FUSED OPTIONAL ACCESSORIES: Current Clamp CA 300, Current Clamp Adaptor CA500, CA1000, CA2000, High Voltage Probe PD-28.

Similar Manuals in the Multimeter Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Perel EVM1400

Perel Multimeter Operation & user’s manual (File: PDF, 26-07-2026)

60 386 89 26-07-2026 view all manuals
IDEAL ND 2385-1

ND 2385-1 Instructions manual - 3N7T26

12 1134 239 12-03-2026 view all manuals
Velleman DVM630

Velleman Multimeter Operation & user’s manual (File: PDF, 25-04-2026)

56 324 69 25-04-2026 view all manuals
Klein Tools MM6000

MM6000 Instruction manual - 196TU7

2 590 124 03-08-2026 view all manuals
Fluke i410

i410 Instruction sheet - 846T37

8 357 83 27-05-2026 view all manuals
wurth 0715 53 390

wurth 0715 53 390 User Manual (Instructions manual), @ZP176E

56 1170 246 24-07-2026 view all manuals