La Marche ESCR Manuals

2 pdf manual(s) La Marche ESCR for free download (Document Types: Installation and operation manual, Quick start manual)

Document Preview & Text Transcription

La Marche Manufacturing Company | www.lamarchemfg.com ESCR Engine Starting Battery Charger Installation and Operation Manual 106 Bradrock Dr. Des Plaines 60018-1967 CPN117485 Tel: 847 299 1188 Fax: 847 299 3061 Instruction Drawing Number: P25-LESCR-1 Revision A10 Rev. Date: 10/16 ECN: 21270 i Important Safety Instructions Before using this equipment read all manuals and other documents related to this unit and other equipment connected to this unit. Always have a copy of a units manual on file nearby, in a safe place; if a replacement copy of a manual is needed it can be found at www.lamarchemfg.com. Electrical Safety WARNING: Hazardous Voltages are present at the input of power systems. The output from rectifiers and from batteries may be low in voltage, but can have a very high current capacity that may cause severe or even fatal injury. When working with any live battery or power system, follow these precautions:  Never work alone on any live power systems; someone should always be close enough to come to your aid.  Remove personal metal items such as rings, bracelets, necklaces, and watches.  Wear complete eye protection (with side shields) and clothing protection.  Always wear gloves and use insulated hand tools. WARNING: Lethal Voltages are present within the power system. Parts inside the unit may still be energized even when the unit has been disconnected from the AC input power. Check with a meter before proceeding. Do not touch any uninsulated parts.  A licensed electrician should be used in the installation of any unit.  Always disconnect the unit from the supply, batteries and loads before performing maintenance or cleaning.  If the unit is hot-swappable, simply remove it from the shelf for any maintenance or cleaning.  Always assume that an electrical connection is live and check the connection relative to ground.  Be sure that neither liquids nor any wet material come in contact with any internal components.  Do not operate this unit outside the input and output ratings listed on the unit nameplate.  Do not use this unit for any purpose not described in the operation manual. Mechanical Safety  This unit or parts of the unit may get very hot during normal operation, use care when working nearby.  Do not expose equipment to rain or snow. Always install in a clean, dry location.  Do not operate equipment if it has received a sharp blow, been dropped, or otherwise damaged in any way.  Do not disassemble this unit. Incorrect re-assembly may result in a risk of electric shock or fire. Battery Safety WARNING: Follow all of the battery manufacturer’s safety recommendations when working with or around battery systems. DO NOT smoke or introduce a spark or open flame in the vicinity of a battery. Some batteries generate explosive gases during normal battery operation.  To reduce risk of arc, connect and disconnect the battery only when the unit is off.  If it is necessary to remove battery connections, always remove the grounded terminal from the battery first.  Remove personal metal items such as rings, bracelets, necklaces, and watches.  Always wear rubber gloves, safety glasses, and a rubber lined vest/apron when working near a battery.  Have plenty of fresh water and soap nearby in case the battery electrolyte contacts skin, clothing, or eyes.  If the battery electrolyte contacts skin or clothing, wash immediately with soap and water.  If the electrolyte enters the eye, immediately flood the eye with running cold water for at least ten (10) minutes and seek medical attention immediately.  Do not drop metal on a battery. A spark or short-circuit could occur and could cause an explosion. ii Unit Location  Allow at least 3 inches of free air on all vented surfaces (and external heatsinks) for proper cooling.  Allow sufficient clearance to open the front panel for servicing.  Do not operate this unit in a closed-in area or restrict ventilation in any way.  Do not set any battery on top of this unit.  Never allow battery electrolyte to drip on this unit when reading the specific gravity or filling the battery.  Never place this unit directly above a standard flooded battery. Gases from the battery will corrode and damage equipment.  A sealed maintenance free or valve regulated lead acid (VRLA) battery may be placed below this equipment. Check for Damages Prior to unpacking the product, note any damage to the shipping container. Unpack the product and inspect the exterior of product for damage. If any damage is observed, contact the carrier immediately. Contact La Marche for advice on the risk due to any damage before installing the product. Verify that you have all the necessary parts per your order for proper assembly. CAUTION: Failure to properly file a claim for shipping damages, or provide a copy of the claim to La Marche, may void warranty service for any physical damages reported for repair. Returns for Service Save the original shipping container. If the product needs to be returned for service, it should be packaged in its original shipping container. If the original container is damaged/unavailable, make sure the product is packed with at least three inches of shock-absorbing material to prevent shipping damage. La Marche is not responsible for damage caused by improper packaging of returned products. Inspection Checklist ・ Enclosure exterior is not marred or dented. ・ There are no visibly damaged components. ・ All hardware and connections are tight. ・ All wire terminations are secure. ・ All items on packing list have been included. Handling Equipment can be very heavy and/or top heavy. Use adequate manpower or equipment for handling. Until the equipment is securely mounted, care must be used to prevent the equipment from being accidentally tipped over.

Document Preview & Text Transcription

ESCR Quick Start Guide La Marche ESCR Engine Starting Battery Charger: Getting started La Marche Mfg. (A U.S. Company) 106 Bradrock Drive, Des Plaines, IL 60018 Tel: 847.299.1188 Fax: 847.299.3061 [email protected] www.lamarchemfg.com WARNING: Please read the Important Safety Instructions before proceeding. 1 Remove Bottom Panel Make Sure to check for any shipping damages before getting started. 1 2 Connect AC 120/208-240. Te unit automatically detects the AC input without changing any taps or switches. Battery does not need to be connected during configuration mode. 3 To change setting, you must enter the configuration mode by pressing the CONFIG/OK red button located on the front panel. The unit does not supply output in the configuration mode. Units are factory set at 12 Volt. Reset Button OK Button Cell Type 6 Lead Acid Float Voltage 2.25 Volts per Cell Equalize Voltage 2.33 Volts per Cell Equalize Timer 8hr - Equalize Timer Manual - Equalize Cycle Current Limit 105% Temperature Compensation Disabled Alarm Setting Alarm Delay - 5 Sec Low VDC - 1.98 VDC High VDC - 2.45 VDC Low DC Current - 0.5 Amps AC Failure . . . . . . . . ESCR-40/20-12/24V-AV1: ESCR-20/10-12/24V-AV1 Configuration Mode Adjustments Use the up/down arrows to browse the selections. The asterisk next to the selection denotes the selected mode. CONFIG/OK button is used as save or enter key and the RESET/BACK button is used as canel or step back in the menu. Basic Output DC Output and Current Number of Cells Float Voltage Adjustable Volts/Cell using the arrows Equalize Voltage Adjustable Volts/Cell using the arrows Equalize Timer Equalize Hours Equalize Cycle Current Limit Adjustable using the arrow keys 50 - 110% Temperature Comp Select Enable or Disable Alarm Settings Alarm Delay Low VDC High VDC Low DC Current AC Failure Factory Settings Restore all alarms to default values The unit Basic Output settings do not change 4 Turn unit OFF and connect battery to POS and NEG terminals . . . . .. . . ..... .. For detailed information please refer to the Instruction Manual ESCR Battery Charger Settings Operation Function Configure Mode Configure/OK Basic Settings Float Voltage Equalize Voltage Equalize Timer Current Limit Temperature Compensation Adjustable Volts/Cells Adjustable Volts/Cells Enable Disable Alarm Settings Adjustable from 50 to 110% Output Voltage and Current Number of Cells Equalize Hours Equalize Cycle Alarm Delay Low VDC High VDC Low DC Current AC Failure 1-144 8 Hrs Default Manual 7 Days 14 Days 30 Days Auto- Low DC Auto – AC Fail 6L 9NC 10 NC 12 Volt 10 Amp 12 Volt 20 Amp 24 Volt 10 Amp Adjustable Alarms Contacts