Laird Sentrius RS1 Series Manuals

4 pdf manual(s) Laird Sentrius RS1 Series for free download (Document Types: Operation & user’s manual)

Document Preview & Text Transcription

A User Guide Sentrius™ RS1xx Version 1.0 This datasheet has been downloaded from http://www.digchip.com at this page Sentrius™ RS1xx User Manual Embedded Wireless Solutions Support Center: http://ews-support.lairdtech.com www.lairdtech.com/ramp 2 © Copyright 2017 Laird. All Rights Reserved Americas: +1-800-492-2320 Europe: +44-1628-858-940 Hong Kong: +852 2923 0610 REVISION HISTORY Version Date Notes Contributor Approver 1.0 05 Dec 2017 Initial version Christopher Hofmeister Jonathan Kaye Sentrius™ RS1xx User Manual Embedded Wireless Solutions Support Center: http://ews-support.lairdtech.com www.lairdtech.com/ramp 3 © Copyright 2017 Laird. All Rights Reserved Americas: +1-800-492-2320 Europe: +44-1628-858-940 Hong Kong: +852 2923 0610 CONTENTS 1 About this Guide ................................................................................................................................................ 4 2 Introduction ....................................................................................................................................................... 4 3 Powering Up the Sensor .................................................................................................................................... 5 4 Connecting to A LoRa network Server ............................................................................................................... 6 4.1 AppEUI ....................................................................................................................................................... 6 4.2 DevEUI ....................................................................................................................................................... 6 4.3 AppKey ....................................................................................................................................................... 7 5 Adaptive Data Rate (ADR).................................................................................................................................. 8 6 Device Operation ............................................................................................................................................. 10 6.1 Care and Maintenance ............................................................................................................................ 10 6.2 Positioning of the Sensor ......................................................................................................................... 10 6.3 LoRa Messages ........................................................................................................................................ 11 6.4 Join Sequence .......................................................................................................................................... 11 6.5 Ack/Retires .............................................................................................................................................. 11 6.6 Disconnect ............................................................................................................................................... 12 6.7 Network Time .......................................................................................................................................... 12 6.8 Backlog Feature ....................................................................................................................................... 13 6.9 Measuring Humidity ................................................................................................................................ 13 6.10 Setting up the Sensor .............................................................................................................................. 13 6.11 Sensor Firmware Version......................................................................................................................... 14 7 Configuration ................................................................................................................................................... 14 7.1 Label (back label space) ........................................................................................................................... 14 7.2 Device Configuration ............................................................................................................................... 15 8 Mobile Application .......................................................................................................................................... 15 8.1 Overview .................................................................................................................................................. 15 8.2 Install Sentrius™ Sensor Mobile App on Device ...................................................................................... 15 8.3 Connect to Sentrius™ Sensor................................................................................................................... 16 8.4 Main Screen ............................................................................................................................................. 17 8.5 Configure Device ..................................................................................................................................... 17 8.6 View Sensor Data ..................................................................................................................................... 18 8.7 LoRa Configuration .................................................................................................................................. 19 8.8 LoRa Network .......................................................................................................................................... 19 8.9 BLE Info .................................................................................................................................................... 20 8.10 Update Firmware ..................................................................................................................................... 20 8.11 Integrating Sentrius™ Sensor into a Third Party Application .................................................................. 21 9 Bluetooth SIG ................................................................................................................................................... 22 10 FCC and ISED Canada Regulatory Statements ............................................................................................. 22 11 CE Regulatory .............................................................................................................................................. 23 12 EU Declarations of Conformity .................................................................................................................... 24 13 Ordering Information .................................................................................................................................. 25 14 Future Variants ............................................................................................................................................ 27 14.1 External Sensor Port ................................................................................................................................ 27 15 Additional information ................................................................................................................................ 27 Sentrius™ RS1xx User Manual Embedded Wireless Solutions Support Center: http://ews-support.lairdtech.com www.lairdtech.com/ramp 4 © Copyright 2017 Laird. All Rights Reserved Americas: +1-800-492-2320 Europe: +44-1628-858-940 Hong Kong: +852 2923 0610 1 ABOUT THIS GUIDE This document is the parent guide of the RS1xx Configuration Guide. It provides a comprehensive guide on how to configure the Sentrius™ RS186 and RS191 sensors to suit the intended application. It covers all Sentrius™ RS1xx functionality, including Bluetooth and LoRa configurations in detail, as well as setting up the sensor on a LoRa network server. Note: Step by step instructions, screen shots, and pictures are based on the Sentrius™ RS191, but the same are applicable for the Sentrius™ RS186. Any differences are noted. 2 INTRODUCTION 2.1 Product Overview The Sentrius™ RS1xx LoRa-Enabled Sensor from Laird is the ultimate in secure, scalable, robust LoRa solutions for end-to-end control of your private LoRaWAN network. Based on the Semtech SX1272 chipset, it offers a long range up to ten miles, perfect for highly scalable, flexible IoT networks. The Sentrius™RS1xx Sensor works with Laird’s Sentrius™RG1xx Series Gateways for simple out-of-the-box integration and is compatible with third-party cloud and LoRa partners. Figure 1: Top of the Sentrius™ RS1xx Sensor 1. Temperature and humidity sensor 2. Bluetooth button 3. LEDs 4. Fixing holes Figure 2: Back side of the Sentrius™ RS1xx Sensor Note: Laird has a comprehensive staff of design services engineers available to help customize the sensor. Please contact your local Laird sales representative for more details.

Document Preview & Text Transcription

A ™ Version 1.7 https://www.lairdconnect.com/wireless-modules/lorawan- solutions 2 © Copyright 2019 Laird. All Rights Reserved Americas: +1-800-492-2320 Europe: +44-1628-858-940 Hong Kong: +852 2923 0610 Version Date Notes Contributor Approver 1.0 05 Dec 2017 Initial version Christopher Hofmeister Jonathan Kaye 1.1 09 Apr 2018 Indicated that the Sentrius™ Sensor with an external sensor port (RJ45) will be available rather than is available. Mark Cai Jonathan Kaye 1.2 17 Oct 2018 Updated for firmware version 4.4. Added in Packet Format and Packet Type sections. Colin Anderson Jonathan Kaye 1.3 19 Dec 2018 Updated logos and URLs Sue White Jonathan Kaye 1.4 May 2019 Reset button, LIFO, and FIFO backlog retrieval. Updated rest of doc for clarity. Colin Anderson Jonathan Kaye 1.5 July 2019 Introduction of AS923 and AU915 regions. Colin Anderson, Mark Monson, Daniel Cesarz Jonathan Kaye 1.6 15 Aug 2019 Added AS923 Region Label Support within various sections and created Section 16 Robert Gosewehr Jonathan Kaye 1.7 28 Aug 2019 Reflect new part numbers and modified ext. probe specification Chris Boorman Jonathan Kaye https://www.lairdconnect.com/wireless-modules/lorawan- solutions 3 © Copyright 2019 Laird. All Rights Reserved Americas: +1-800-492-2320 Europe: +44-1628-858-940 Hong Kong: +852 2923 0610 1 About this Guide ...................................................................................................................................................................................... 4 2 Introduction .............................................................................................................................................................................................. 4 2.1 Product Overview .......................................................................................................................................................................... 4 2.2 Specifications ................................................................................................................................................................................ 4 2.3 Architecture Overview .................................................................................................................................................................... 5 3 Powering Up the Sensor .......................................................................................................................................................................... 5 3.1 Battery Types ................................................................................................................................................................................ 5 3.2 Inserting Batteries .......................................................................................................................................................................... 5 4 Connecting to a LoRa network Server ...................................................................................................................................................... 6 4.1 AppEUI .......................................................................................................................................................................................... 6 4.2 DevEUI .......................................................................................................................................................................................... 6 4.3 AppKey .......................................................................................................................................................................................... 7 5 Configuring the Packet Format ................................................................................................................................................................. 7 6 Configuring the Packet Type .................................................................................................................................................................... 9 7 Adaptive Data Rate (ADR) ....................................................................................................................................................................... 9 7.1 Definitions ...................................................................................................................................................................................... 9 7.2 Data Rate, Sensor Performance, and Tradeoffs .......................................................................................................................... 10 7.3 MAC Commands and the LoRa Standard .................................................................................................................................... 10 8 Device Operation ................................................................................................................................................................................... 11 8.1 Care and Maintenance ................................................................................................................................................................ 11 8.2 Positioning of the Sensor ............................................................................................................................................................. 11 8.3 LoRa Messages ........................................................................................................................................................................... 11 8.4 Join Sequence ............................................................................................................................................................................. 11 8.5 Ack/Retries .................................................................................................................................................................................. 12 8.6 Disconnect ................................................................................................................................................................................... 12 8.7 Network Time .............................................................................................................................................................................. 12 8.8 Backlog Feature .......................................................................................................................................................................... 13 8.9 Measuring Humidity ..................................................................................................................................................................... 13 8.10 Setting up the Sensor .................................................................................................................................................................. 13 8.11 Sensor Firmware Version ............................................................................................................................................................ 14 8.12 Resetting the Sensor ................................................................................................................................................................... 14 9 Configuration ......................................................................................................................................................................................... 15 9.1 Label (Back Label Space) ............................................................................................................................................................ 15 9.2 Device Configuration ................................................................................................................................................................... 15 10 Mobile Application .................................................................................................................................................................................. 16 10.1 Overview ..................................................................................................................................................................................... 16 10.2 Install Sentrius™ Sensor Mobile App on Device .......................................................................................................................... 16 10.3 Connect to Sentrius™ Sensor...................................................................................................................................................... 16 10.4 Main Screen ................................................................................................................................................................................ 17 10.5 Configure Device ......................................................................................................................................................................... 17 10.6 View Sensor Data ........................................................................................................................................................................ 18 10.7 LoRa Configuration ...................................................................................................................................................................... 19 10.8 LoRa Network .............................................................................................................................................................................. 19 10.9 BLE Info ...................................................................................................................................................................................... 20 10.10 Update Firmware ......................................................................................................................................................................... 20 10.11 Integrating Sentrius™ Sensor into a Third-Party Application ........................................................................................................ 21 11 Bluetooth SIG ........................................................................................................................................................................................ 22 12 FCC and ISED Canada Regulatory Statements ..................................................................................................................................... 22 12.1 Power Exposure Information ........................................................................................................................................................ 22 12.2 OEM Responsibilities ................................................................................................................................................................... 22 13 CE Regulatory ....................................................................................................................................................................................... 23 13.1 EU Declarations of Conformity ..................................................................................................................................................... 23 14 Ordering Information .............................................................................................................................................................................. 24 14.1 Evaluation Kit Details (applies to 455-0001, 455-0002 as well as other regional variants) ............................................................ 25 15 Other Variants ........................................................................................................................................................................................ 25 15.1 External Sensor Port .................................................................................................................................................................... 25 16 Label Info ............................................................................................................................................................................................... 26 17 Additional information ............................................................................................................................................................................ 27 18 Appendix A - Cayenne packet format ..................................................................................................................................................... 27 https://www.lairdconnect.com/wireless-modules/lorawan- solutions 4 © Copyright 2019 Laird. All Rights Reserved Americas: +1-800-492-2320 Europe: +44-1628-858-940 Hong Kong: +852 2923 0610 This document is the parent guide of the RS1xx Configuration Guide. It provides a comprehensive guide on how to configure the Sentrius™ RS186 and RS191 sensors to suit the intended application. It covers all Sentrius™ RS1xx functionality, including Bluetooth and LoRa configurations in detail, as well as setting up the sensor on a LoRa network server. In order to comply with the LoRaWAN spec, Laird offers several different versions of the Sentrius Sensor. Regions covered include Europe (EU), North America (US) and Australia (AU915). Also covered is the Asia(AS) region but, in order to meet local regulatory requirements, this region is covered by individual firmware versions for each country. Note: Step by step instructions, screen shots, and pictures are based on the Sentrius™ RS191, but the same are applicable for the Sentrius™ RS186 or other variants. Any differences are noted. The Sentrius™ RS1xx LoRa-Enabled Sensor from Laird is the ultimate in secure, scalable, robust LoRa solutions for end-to-end control of your private LoRaWAN network. Based on the Semtech SX1272 chipset, it offers a long range up to ten miles, perfect for highly scalable, flexible IoT networks. The Sentrius™RS1xx Sensor works with Laird’s Sentrius™RG1xx Series Gateways for simple out-of- the-box integration and is compatible with third-party and LoRa network servers. Figure 1: Top of the Sentrius™ RS1xx sensor 1. Temperature and humidity sensor 2. Bluetooth button 3. LEDs 4. Fixing holes Figure 2: Back side of the Sentrius™ RS1xx sensor Note: Laird has a comprehensive staff of design services engineers available to help customize the sensor. Please contact your local Laird sales representative for more details. See the RS1xx product brief for detailed specifications. It’s available from the Documentation tab of the RS1xx Series product page: https://www.lairdconnect.com/wireless-modules/lorawan-solutions/sentrius-rs1xx-lora-enabled-sensors

Document Preview & Text Transcription

A https://www.lairdconnect.com 1 © Copyright 2018 Laird. All Rights Reserved Americas: +1-800-492-2320 Europe: +44-1628-858-940 Hong Kong: +852 2923 0610 Version 1.1 https://www.lairdconnect.com 2 © Copyright 2019 Laird. All Rights Reserved Americas: +1-800-492-2320 Europe: +44-1628-858-940 Hong Kong: +852 2923 0610 Version Date Notes Contributors Approver 1.0 07 Jan 2019 Initial Release Robert Gosewehr Chris Hofmeister 1.1 28 Aug 2019 Reflect new part numbers and modified probe specification Chris Boorman Jonathan Kaye https://www.lairdconnect.com 3 © Copyright 2019 Laird. All Rights Reserved Americas: +1-800-492-2320 Europe: +44-1628-858-940 Hong Kong: +852 2923 0610 1 Introduction .......................................................................................................................................................................... 4 2 Part Numbers ...................................................................................................................................................................... 4 3 Installation ........................................................................................................................................................................... 5 3.1 Illustrations ................................................................................................................................................................. 6 3.1.1 Stainless Steel Temperature Probe with RJ45 Cable Assembly .......................................................................... 6 3.1.2 RJ45 Cable Gland ................................................................................................................................................ 7 4 Connection Status ............................................................................................................................................................... 8 5 Data Visualization ................................................................................................................................................................ 9 5.1 Sentrius Sensor Mobile App ....................................................................................................................................... 9 6 Battery Consumption ......................................................................................................................................................... 10 7 Sanitation and Cleanliness ................................................................................................................................................ 10

Document Preview & Text Transcription

A Version 2.0 https://www.lairdconnect.com 2 © Copyright 2020 Laird Connectivity, Inc. All Rights Reserved Americas: +1-800-492-2320 Europe: +44-1628-858-940 Hong Kong: +852 2923 0610 Version Date Notes Contributors Approver 1.0 07 Jan 2019 Initial Release Robert Gosewehr Chris Hofmeister 1.1 28 Aug 2019 Reflect new part numbers and modified probe specification Chris Boorman Jonathan Kaye 2.0 14 July 2020 Updates to incorporate new RTD ext. temp sensor Chris Boorman Jonathan Kaye https://www.lairdconnect.com 3 © Copyright 2020 Laird Connectivity, Inc. All Rights Reserved Americas: +1-800-492-2320 Europe: +44-1628-858-940 Hong Kong: +852 2923 0610 1 Introduction .......................................................................................................................................................................... 4 2 Product Overview ................................................................................................................................................................ 4 3 Installation ........................................................................................................................................................................... 5 3.1 Illustrations ................................................................................................................................................................. 6 3.1.1 External Temperature Probe Cable Assemblies ................................................................................................... 6 3.1.2 RJ45 Cable Gland ................................................................................................................................................ 7 4 Connection Status ............................................................................................................................................................... 8 5 Data Visualization ................................................................................................................................................................ 9 5.1 Sentrius Sensor Mobile App ....................................................................................................................................... 9 6 Battery Consumption ......................................................................................................................................................... 10 7 Sanitation and Cleanliness ................................................................................................................................................ 10 https://www.lairdconnect.com 4 © Copyright 2020 Laird Connectivity, Inc. All Rights Reserved Americas: +1-800-492-2320 Europe: +44-1628-858-940 Hong Kong: +852 2923 0610 This user guide explains how to properly install both the original RS1xx External Temperature Probe, with its 1-Wire integrated digital thermometer, along with the latest RS1xx External RTD Temperature Probe, with a Class A PT100 RTD. The guide also explains how to view sampled data using the Sentrius Sensor Mobile App. Both variants of the Sentrius RS1xx series of LoRa / BLE Sensors enable use of an external cabled temperature probe, in place of the integrated temperature sensor. Each of the sensors are IP67 rated cable assemblies with a stainless-steel probe, the difference in physical probe dimensions and supported operational temperature is outlined below. The cabled probes connect into the main body of the Sentrius Sensor via a CAT5 IP67 rated RJ45 connector. Note: This guide only contains a brief walkthrough. Refer to the RS1xx Guide for further details on sensor functionality and the mobile app capabilities. To access the RS1xx Guide, navigate to the RS1xx product page, click Documentation, and select the Sentrius RS1xx User Guide. Figure 1: Sentrius sensor enclosure with external digital temperature probe Reference Description Left IP67-rated, 1-Wire integrated digital sensor, -55° to +125°C range, 1520 mm cable length, 213 mm probe length, 6.0 mm dia. stainless steel temperature probe CAT5 RJ45 connector Right Sentrius™ RS1xx LoRaWAN Ext. Port Temp Sensor Figure 2: Sentrius sensor enclosure with external RTD temperature probe Reference Description Left IP67-rated, Class A PT100 RTD sensor, -40° to +180°C range, 1320 mm cable length, 100 mm probe length, 4.0 mm dia. stainless steel temperature probe CAT5 RJ45 connector Right Sentrius™ RS1xx LoRaWAN Ext. Port Temp Sensor The external temperature probe is ordered separately from the Sensor body, in single or bulk. See the Laird RS1xx product page for ordering information.