LEGRAND Bticino HD4607/4 Manuals

2 pdf manual(s) LEGRAND Bticino HD4607/4 for free download (Document Types: Technical sheet, Quick start manual)

LEGRAND Bticino HD4607/4 Technical sheet [PDF] (518 pages)

  • Identifier: id-1588805
  • Brand: LEGRAND
  • Device: Bticino HD4607/4 Home Automation
  • Type: PDF
  • Key Aspects: Hardware Verification Checklists, End-of-Life Handling and Disposal, Troubleshooting Information
  • UPD Date: 15.03.2026
  • Source File: 1591909.pdf
  • Pages: 518
  • Description: Owner’s guide for the LEGRAND Bticino HD4607/4.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Technical sheets

LEGRAND Bticino HD4607/4 Quick start manual [PDF] (2 pages)

  • Identifier: id-1437924
  • Brand: LEGRAND
  • Device: Bticino HD4607/4 Marine Radio
  • Type: PDF
  • Key Aspects: Efficiency and Calibration Tips, Best Practices for Everyday Use, Control Panel and Interface Navigation
  • UPD Date: 06.04.2026
  • Source File: 1560519.pdf
  • Pages: 2
  • Description: Quick reference guide for the LEGRAND Bticino HD4607/4.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 1 4 2 6 5 7 3 �� ��� � ��� �� ��� � ��� �� ��� � ��� �� ��� � ��� HD4607/4 HC4607/4 N4607/4 L4607/4 NT4607/4 AM5787/4 HS4607/4 Description This device is used to arm, disarm, and separate the zones of the system by placing a transponder badge (item 3530S and item 3540 previously stored in the central unit) in front of the zone transponder badge receiver. When used in an automation system it performs the control function for the management of scenarios. By pressing one of the pushbuttons, the corresponding zone is armed/disarmed. Within four seconds from the last pressure, the separation performed must be confirmed by moving a transponder saved in the central unit close to the device. Should this not take place, then the previous condition is automatically restored. Red LEDs on indicate that the zones are active, whereas red LEDs off show that they are disarmed. Configuration BURGLAR-ALARM mode: Since this item belongs to the activator group, it needs to be set up with the number of the “group” assigned and the progressive number of the devices in the “group”. It can also be programmed to perform Automation functions (scenario management). See Automation “MY HOME” guide for details. Z This configurator assigns the number of the appropriate zone (from 1 to 8) in the “group” of devices (any free zone in the system). To configure it as belonging to the activator group, no configurator must be inserted. N° This configurator assigns the progressive number within the group of activators. Configurator 1 identifies the first device, configurator 2 identifies the second, and so forth, up to a maximum of 9 activators (dividers, expanders or activators). NOTE: If all 9 permitted devices have already been assigned to the activator group, it could be possible to assign to configurator Z (zone it belongs to) a value between 1 and 9, taking into account the progressive number. MOD It assigns the modes of the audible signals (BEEP) and luminous signals (LED ON) provided by the divider when controlled by the transponder; it is used as a activators/ disconnector of the “Burglar-alarm” system. Technical data - Power supply from SCS BUS: 27 Vdc - Max. absorption: 15 mA - Operating temperature: 5 – 40°C Legend 1 - Transponder badge receiver zone; 2 - LED and pushbutton for controlling of zone 2; 3 - LED and pushbutton for controlling of zone 4; 4 - Indication “System ON/OFF”; 5 - Alarm warning; 6 - LED and pushbutton for controlling of zone 3; 7 - LED and pushbutton for controlling of zone 1. Dimensional data Size: 2 modules AUX Position not configurable for the “Burglar-alarm” function; configure only if it is necessary to enable the device for Automation functions (management of the scenarios stored in the unit or scenario module). Front view Z No. MOD AUX Clamp for burglar alarm BUS Rear view Central unit used Configurator value LED ON Enabling BEEP 3486 3485/B HD/HC/HS/L/N/ NT4601 none YES YES 1 NO YES 2 YES NO 3 NO NO L/N/NT4600/1 A/AM5780/1 4 YES YES 5 NO YES 6 YES NO 7 NO NO 1-4 zone transponder divider MQ00028-c-EN 24/04/2014

Bticino HD4607/4: Related Instructions

Solarfective SF-T4
LEGRAND Solarfective SF-T4
05.04.2026 3 pages

Solarfective ® Televent Installation Instructions No: D000047 – 11/19 rev. 1 Catalog Numbers • Les Numéros de Catalogue • Los Números de Catálogo: S Product setup manual for the LEGRAND Solarfective SF-T4 Industrial Equipment. This guide offers instructions on warranty information, installation procedures, maintenance.

0 488 14
LEGRAND 0 488 14
25.07.2026 4 pages

87045 LIMOGES Cedex Telephone: +33(0)5 55 06 87 87 - Fax: +33(0)5 55 06 88 88 Technical data sheet: S000079749-EN Cat. No(s): 0 488 14 Updated on: Created: 17/ Device maintenance guide for the LEGRAND 0 488 14 Kitchen Appliances. This guide explains the features and security instructions, network setup, shutdown procedures.

Whad 0.8 kVA
LEGRAND Whad 0.8 kVA
17.05.2026 88 pages

® Part. LE05733AA-07/12-01 GF Whad 0.8, 1, 1.5 kVA Manuel d’installation • Installation manual Instruction manual for the LEGRAND Whad 0.8 kVA UPS. It provides instructions for wiring setup, functional overview, operational guidelines, troubleshooting.

Wattstopper DT-355
LEGRAND Wattstopper DT-355
12.04.2026 17 pages

Wattstopper ® 360° Dual Technology • Line Voltage Occupancy Sensor (version 3) with Light Level feature Double technologie à 360° • Détecteur de mouvem Operation and maintenance manual for the LEGRAND Wattstopper DT-355 Kitchen Appliances. The document provides guidance on safety and connectivity options, installation support, operation.

Sagane 846 37
LEGRAND Sagane 846 37
17.08.2026 4 pages

• Thermostat programmable • Programmeerbare thermostaat • Programmable thermostat • Πργραµµατι µενς θερµστάτης • Régulatio Operating manual for the LEGRAND Sagane 846 37 Thermostat. This guide provides information on hardware instructions, user preferences, device reset instructions, repair references.

Kenall LOW PROFILE SCONCE LPS Series
LEGRAND Kenall LOW PROFILE SCONCE LPS Series
08.06.2026 4 pages

www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA This product complies with the Buy American Act: manu Product reference manual for the LEGRAND Kenall LOW PROFILE SCONCE LPS Series Racks & Stands. It offers details on dimensions and layout, interface navigation, firmware installation.

Similar Manuals in the Home Automation, Marine Radio Category

MARINE MR HH330 FLT EU
Cobra MARINE MR HH330 FLT EU
14.03.2026 27 pages

VHF MARINE RADIO MR HH330 FLT EU Printed in China Part No. 480-551-P Version D Owner’s Manual Nothing Comes Close to a Cobra® English A1 English Our Thank Instruction and reference manual for the Cobra MARINE MR HH330 FLT EU Marine Radio. It details safety instructions and error codes, product specifications, system configuration.

VX8500 Black
LG VX8500 Black
16.06.2026 179 pages

P/N : MMBD0063101 Service Manual VX8500 Service Manual Model : VX8500 Z3X-BOX.COM Quick reference guide for the LG VX8500 Black Cell Phone. It provides guidance on regulatory notices, adjustment procedures, user preferences.

AIT1500
DIGITAL YACHT AIT1500
14.03.2026 7 pages

AIT1500 CLASS B AIS TRANSPONDER Product instruction handbook for the DIGITAL YACHT AIT1500 Marine Radio. This guide presents instructions on installation support, safety, maintenance guidelines, network setup.

IC-F3GS
Icom IC-F3GS
30.06.2026 16 pages

1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003 Japan A-5621D-1EX-r Printed in Japan © 1999 Icom Inc. Count on us! IC-F3/4GS series INSTRUCTION MANUAL UHF TRANSC Installation guide for the Icom IC-F3GS Two-Way Radio. The guide offers support information and operating conditions, testing procedures, basic operation, user settings.