Leviton 5480 Manuals

2 pdf manual(s) Leviton 5480 for free download (Document Types: Installation instructions)

Document Preview & Text Transcription

PK-92695-10-02-0A PK-92695-10-02-0A LIMITED TEN YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for ten years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such ten year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to ten years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise. For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) 1 800 405-5320 (Canada only) www.leviton.com Surge Protective Receptacles 15A-120VAC, 60Hz Cat. Nos. 5480 and 5480-IG (Commercial Grade) Cat. Nos. 8480 and 8480-IG (Hospital Grade) 20A-120VAC, 60Hz Cat. Nos. 5490 and 5490-IG (Commercial Grade) Cat. Nos. 8490 and 8490-IG (Hospital Grade) INSTALLATION INSTRUCTIONS Prises avec protecteur de sur tensions 15 A, 120 V c.a., 60Hz N°s de cat. 5480 et 5480-IG (Qualité commerciale) N°s de cat. 8480 et 8480-IG (Qualité hôpital) 20 A, 120 V c.a., 60Hz N°s de cat. 5490 et 5490-IG (Qualité commerciale) N°s de cat. 8490 et 8490-IG (Qualité hôpital) DIRECTIVES D’INSTALLATION Receptáculos Protectores de Sobretensión 15A-120VCA, 60Hz Nos. de Cat. 5480 y 5480-IG (Calidad Comercial) Nos. de Cat. 8480 y 8480-IG (Calidad Hospital) 20A-120VCA, 60Hz Nos. de Cat. 5490 y 5490-IG (Calidad Comercial) Nos. de Cat. 8490 y 8490-IG (Calidad Hospital) INSTRUCCIONES DE INSTALACION English FEATURES • UL 1449 TVSS rated • Impact-resistant nylon construction • 3 protection modes: L-N, L-G, N-G • Backwire ground • EMI/RFI filter for radio/TV interference INTRODUCTION Leviton’s Four-In-One Surge Protection Receptacles are designed to reduce the random energy surges of voltage transients and electrical noise on the power supply line. Leviton’s Four-In-One Surge Protective Receptacles can be used to protect sensitive electronic equipment in industrial, commercial and residential locations, from the stress and degradation inflicted by voltage transients. Isolated Ground (-IG) Surge Protective Receptacles provide a pure grounding path isolated from the normal grounding means which employs the unit’s mounting strap. The diagnostics LED indicator light is ON continuously when protection is active, but turns OFF when protection circuit is deactivated due to excessive transients. The entire unit must be replaced if surge protection is required. If the unit is not replaced, it will function only as a conventional receptacle within its given rating. Leviton’s Four-In-One Surge Protective Receptacles are UL listed to mount on a standard single wall box without an adapter plate. However, you may use the Leviton Cat. No. 3254 Adapter Plate in all applications for a more decorative look. This plate is sold separately. The Leviton Portable Box (Cat. No. 4254) can be used to surface mounting where an electrical box does not exist. The Portable Box is sold separately. INSTALLATION INSTRUCTIONS WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS. WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN. WARNING: THIS DEVICE IS NOT A LIGHTNING ARRESTOR. IT WILL NOT SURVIVE LIGHTNING STRIKES IN CLOSE PROXIMITY TO THE PREMISES. OTHER CAUTIONS: 1. INSTALL THIS DEVICE ONLY IN A SINGLE BRANCH CIRCUIT PROTECTED BY A FUSE OR A CIRCUIT BREAKER. 2. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY DEVICES MARKED CO/ALR OR CU/AL. 3. A SURGE PROTECTIVE RECEPTACLE WILL PROVIDE MAXIMUM PROTECTION FOR LOADS PLUGGED DIRECTLY INTO IT. IT WILL PROVIDE SOME PROTECTION TO NEARBY RECEPTACLES, THOUGH PROTECTION DIMINISHES PROPORTIONALLY WITH THE LENGTH OF WIRE RUN. TO INSTALL: 1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AN TEST THAT POWER IS OFF BEFORE WIRING! 2. Remove the insulation on each circuit conductor to expose 1” (2.5 cm) bare copper wire at end of circuit wire. Keep wire ends straight. 3. Connect wires as follows: Twist all strands firmly together. Insert the conductor in the snub hole and wrap the conductor counterclockwise around the terminal screw. BLACK conductor to BRASS screw, WHITE conductor to SILVER screw, and GREEN conductor to GREEN hex screw. Be sure there are no loose strands. If system ground is uninsulated, the pigtail the uninsulated ground wire (which may be provided) from the GREEN hex screw to the electrical box. 4. Tighten terminal screws clockwise. 5. Mount receptacle (refer to Mounting Instructions for you application). 6. Restore power at circuit breaker or fuse. INSTALLATION IS COMPLETE. PORTABLE BOX MOUNTING USE FLEXIBLE CORD ONLY IN THIS CONFIGURATION. NEVER USE WITH UNINSULATED GROUND CONDUCTOR. A GROUND SHORT MAY OCCUR. PORTABLE BOX CONFIGURATIONS ARE NOT UL LISTED. 1. For surface mounting, remove the knockouts in the back of the box. Mount the box on the surface using #6 screws (not provided). Be sure that the box’s cord hole is oriented correctly before mounting the box. 2. Remove the cord jacket about 6” (15.2 cm). Be sure not to damage the insulation. An electrical short of current leakage may occur which may cause harm to the equipment or cause bodily injury. Remove the insulation on each conductor about 1” (2.5 cm). 3. Thread the cord through the box’s cord hole and under the strain relief clamp. 4. Connect wires as follows: Twist all strands firmly together. Insert the conductor in the snub hole and wrap the conductor counterclockwise around the terminal screw. BLACK conductor to BRASS screw, WHITE conductor to SILVER screw, and GREEN conductor to GREEN hex screw. Tighten terminal screws clockwise. Be sure there are no loose strands. 5. Mount the screws into the relief clamps. Tighten each BLACK strain relief clamp into the slot above each cord hole. Ensure that each cord is clamped tightly. 6. Fold wires carefully into box and mount the Surge Protective Receptacle with the four #8-32 x 1” long screws provided. USE COPPER WIRE ONLY MADE IN U.S.A. A CAUTION: MOUNTING ED GROUND SCREW (GREEN) SILVER L SCREWS BRASS SCREWS SNUB HOLE DETAIL HOSPITAL GRADE A B A B 15A-125V Français CARACTÉRISTIQUES • Estimé aussi TVSS en UL 1449 • Fabrication en nylon résistant aux chocs • 3 mode de protection : L-N, L-T, N-T • Mise à la terre par raccordement arrière • Avec filtre d’interférence électromagnétique et radio fréquence INTRODUCTION Les adaptateurs quadriprises avec protecteur de surtensions de Leviton sont conçues pour réduire les crêtes d’énergie aléatoires causées par la présence de surtensions transitoires ou de bruit électrique sur les circuits d’alimentation. Ces prises peuvent protéger le matériel électronique délicat utilisé dans les applications industrielles , commerciales et résidentielles contre les contraintes et la dégradation que peuvent cause les transitoires. Les adaptateurs quadriprises avec mise à la terre isolée (-IG) assurent un parcours de M.A.L.T. isolé, distinct du trajet habituel par la bride de montage de la prise. Elles sont dotées d’in indicateur diagnostique à DEL qui reste continuellement allumé tant que la protection est assurée; il se met à clignoter et s’éteint lorsqu’il y a panne de protection en raison de la présence de surtensions excessives sur le circuit; le cas échéant, on doit remplacer le dispositif si on désire rétablir la protection du système; si le dispositif n’est pas remplacé, il ne pourra être utilisé que comme prise conventionnelle, en respectant les valeurs nominales prescrites. Les adaptateurs quadriprises avec protecteur de surtensions de Leviton s’installe dans les boîtes murales standard, sans nécessiter d’adaptateur; l’adaptateur N° de cat. 3254 peut cependant être utilisé dans toutes les applications pour obtenir une apparence plus élégante; ce adaptateur est vendu séparément. La boîte portative (N° de cat. 4254) de Leviton permet d’encastrer le adaptateur quadriprise là où il n’y a pas d’installation existant; ce dispositif est vendu séparément. DIRECTIVES D’INSTALLATION AVERTISSEMENT : INSTALLER OU UTILISER CONFORMÉMENT AUX CODES DE L’ÉLECTRICITÉ EN VIGUEUR. AVERTISSEMENT : À DÉFAUT DE BIEN COMPRENDRE LES DIRECTIVES SUIVANTES, FAIRE APPEL À UN ÉLECTRICIEN QUALIFIÉ. AVERTISSEMENT : CE DISPOSITIF N’EST PAS UN PARAFOUDRE; IL NE RÉSISTERA PAS AUX COUPS DE FOUDRE À PROXIMITÉ DES LIEUX QU’IL PROTÈGE. AUTRES MISES EN GARDE : 1. INSTALLER CE DISPOSITIF UNIQUEMENT SUR UN CIRCUIT SIMPLE PROTÉGÉ PAR UN FUSIBLE OU UN DISJONCTEUR. 2. N’UTILISER CE DISPOSITIF QU’AVEC DU FIL DE CUIVRE; EN PRÉSENCE DE FIL D’ALUMINIUM, UTILISER SEULEMENT LES DISPOSITIFS PORTANT LA MARQUE CO/ALR OU CU/AL. 3. LES PRISES À DISPOSITIF LIMITEUR DE SURTENSIONS OFFRENT UNE PROTECTION MAXIMALE AUX CHARGES QUI LEUR SONT DIRECTEMENT ENFICHÉES; ELLES PROTÈGENT CEPENDANT LES PRISES AVOISINANTES, MAIS LE NIVEAU DE PROTECTION EST INVERSEMENT PROPORTIONNEL À LA LONGUEUR DU PARCOURS DE FIL. INSTALLATION : 1. AVERTISSEMENT : POUR ÉVITER LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURE MORTELLE, COUPER LE COURANT AU FUSIBLE OU AU DISJONCTEUR ET S’ASSURER QUE LE CIRCUIT SOIT BIEN COUPÉ AVANT DE PROCÉDER À L’INSTALLATION. 2. Dénuder chacun des conducteurs afin d’exposer 2,5 cm de fil de cuivre à chaque extrémité; garder les fils bien tendus. 3. Raccorder les fils de la façon suivante : le conducteur NOIR à la vis LAITON, le conducteur BLANC à la vis ARGENT, et le fil VERT À la vis hexagonal VERT; le cas échéant, torsader le fil de M.A.L.T. qui peut être fourni entre la vis VERT et la boîte murale; insérer le conducteur dans l’orifice d’ancrage et enrouler vers la gauche sur la borne à vis. 4. Serrer les bornes à vis vers la droite. 5. Fixer le adaptateur (consulter les Directives D’installation du type d’application approprié). 6. Rétablir le courant au fusible ou au disjoncteur. L’INSTALLATION EST TERMINÉE. INSTALLATION DANS UNE BOÎTE PORTATIVE N’UTILISER QU DU CORDON FLEXIBLE POUR CETTE APPLICATION; NE JAMAIS UTILISER DE CONDUCTEUR DE M.A.L.T. NON ISOLÉ; CELA POURRAIT CAUSER UNE FUITE À LA TERRE; LES CONFIGURATIONS AVEC BOÎTE PORTATIVE NE SONT PAS HOMOLOGUÉES UL. 1. Pour installer en saillie, retirer les déboucheras à l’arrière de la boîte à la surface au moyen de vis 6 (non comprises) en s’assurant que l’orifice de sortie du cordon est orienté correctement. 2. Retirer du cordon environ 15 cm de gaine; s’assurer de ne pas l’endommager; cela pourrait causer un court-circuit ou une fuite de courant, endommager l’équipement ou causer des blessures; dénuder chacun des conducteurs d’environ 2,5 cm. 3. Faire passer le cordon dans l’orifice de sortie de la boîte, en le plaçant sous le brides. 4. Raccorder les fils de la façon suivante : le conducteur NOIR à la vis LAITON, le conducteur BLANC à la vis ARGENT, et le conducteur VERT à la vis hexagonale VERT; s’assurer qu’aucun brin ne soit exposé. 5. Serrer chaque bride noire dans les fentes au-dessus de chaque orifice de sortie; fixer au moyen de vis; s’assurer que chaque cordon soit solidement maintenu. 6. Fixer le adaptateur au moyen des quatre longues vis 8-32 de 2,5 cm comprises. HOSPITAL GRADE A B A B 15A-125V USE COPPER WIRE ONLY MADE IN U.S.A. A CAUTION: MOUNTING D VIS DE M.A.L.T. (VERT) VIS ARGENT VIS LAITON ORIFICE D'ANCRAGE Español CARACTERISTICAS • Clasificado en UL 1449 como TVSS • Construcción de nylon resistente al impacto • 3 modos de protección: L-N, L-T, N-T • Cableado a tierra posterior • Con filtro de interferencia electromagnética y radio frecuencia INTRODUCCION Los Receptáculos Cuatro-En-Uno Protectores de Sobretensión de Leviton están diseñados para reducir las sobretensiones aleatorias de energía y el ruido eléctrico en las líneas de alimentación de energía. Los Receptáculos Cuatro-En-Uno Protectores de Sobretensión de Leviton pueden usarse para proteger equipo electrónico sensitivo en ubicaciones industriales, comerciales y residenciales, de la presión u degradación infligida por descargas de voltaje. Los Receptáculos Cuatro-En-Uno Protectores de Sobretensión con Tierra Aislada (-IG) proporcionan una ruta de aterrizado pura, aislada de los medios normales de aterrizado que emplean el bastidor de montaje de la unidad. La luz indicadora de diagnósticos DEL (Diodo Emisor de Luz) se ENCIENDE continuamente cuando la protección está activa, pero se APAGA cuando el circuito de protección es desactivado debido a transientes excesivos. La unidad completa debe ser reemplazada si se desea protección de sobretensión. Si la unidad no es reemplazada, funcionará solamente como un receptáculo convencional dentro de su capacidad dada. Los Receptáculos Cuatro-En-Uno Protectores de Sobretensión están catalogados por UL para montarse en una caja de pared sencilla estándar, sin placa adaptadora. Sin embargo, usted puede usar la Placa Adaptadora Leviton No. de Cat. 3254 en todas las aplicaciones para dar un toque más decorativo. Esta placa se vende por separado. La Caja Portátil de Leviton (No. de Cat. 4254) puede ser usada con el Receptáculo Protector de Sobretensión para montaje superficial en donde no exista una caja eléctrica. La Caja Portátil se vende por separado. INSTRUCCIONES DE INSTALACION ADVERTENCIA: PARA INSTALARSE Y/O USARSE DE ACUERDO CON LO CODIGOS ELECTRICOS Y NORMAS APROPIADOS. ADVERTENCIA: SI USTED NO ESTA SEGURO ACERCA DE ALGUNA DE LAS PARTES DE ESTAS INSTRUCCIONES, CONSULTE A UN ELECTRICISTA CALIFICADO. ADVERTENCIA: ESTE PRODUCTO NO ES UN PARARRAYOS. NO SOBREVIVIRA LOS RELAMPAGOS EN PROXIMIDAD CON LAS PREMISAS. OTRAS PRECAUCIONES: 1. INSTALE ESTE PRODUCTO SOLO EN UN CIRCUITO PROTEGIDO POR UN FUSIBLE O INTERRUPTOR DE CIRCUITOS. 2. USE ESTE PRODUCTO SOLO CON CABLE DE COBRE O REVESTIDO DE COBRE. PARA CABLE DE ALUMINIO USE SOLO PRODUCTOS MARCADOS CON EL SIMBOLO CO/ALR O CU/AL. 3. UN RECEPTACULO PROTECTOR DE SOBRETENSION PROPORCIONARA PROTECCION MAXIMA A CARGAS CONECTADAS DIRECTAMENTE EN EL. PROPORCIONARA ALGUNA PROTECCION A RECEPTACULOS ADYACENTES, AUNQUE LA PROTECCION DISMINUYE PROPORCIONALMENTE CON LA LONGITUD DEL CABLEADO. PARA INSTALAR: 1. ADVERTENCIA: PARA EVITAR DESCARGA ELECTRICA, FUEGO O MUERTE, INTERRUMPA EL PASO DE ENERGIA MEDIANTE EL INTERRUPTOR DE CIRCUITO O FUSIBLE. ¡ASEGURESE DE QUE EL CIRCUITO NO ESTA ENERGIZADO ANTES DE INICIAR LA INSTALACION! 2. Quite el aislante en cada conductor para exponer 2.5 cm de alambre de cobre desnudo en cada extremo de los cables del circuito. Mantenga las puntas de los alambres rectas. 3. Conecte los cables como sigue: Tuerza firmemente todos los hilos de cada conductor. Inserte el conductor en el agujero de amarre y enrósquelo hacia la izquierda alrededor del tornillo terminal. El conductor NEGRO al tornillo LATON, el conductor BLANCO al tornillo PLATEADO, y el conductor VERDE al tornillo hexagonal VERDE. Asegúrese de que no haya hilos sueltos. Si el sistema a tierra está sin aislar, conecte el cable de tierra aislada (puede que no se incluya) del tornillo hexagonal VERDE a la caja eléctrica de la pared. 4. Apriete los tornillos hacia la derecha. 5. Monte el receptáculo (vea las Instrucciones de Montaje para su aplicación). 6. Restablezca la energía mediante el interruptor de circuito o fusible. LA INSTALACION ESTA COMPLETA. MONTAJE EN CAJA PORTATIL EN ESTA CONFIGURACION, USE SOLO CORDON FLEXIBLE. NUCA USE CONDUCTOR A TIERRA SIN AISLANTE. UN CORTO A TIERRA PUEDE OCURRIR. LAS CONFIGURACIONES DE LA CAJA PORTATIL NO ESTAN CATALOGADAS POR UL. 1. Para montaje superficial, quite los agujeros ciegos en la parte posterior de la caja. Monte la caja en la superficie usando tornillos #6 (no incluidos). Asegúrese de que el agujero de la caja para el cordón esté correctamente orientado antes de montar la caja. 2. Quite aproximadamente 15.5 cm de forro del cordón. Asegúrese de no dañar el aislante. Un corto eléctrico o falla de corriente puede ocurrir, el cual pudiera causar daños a la salud. Quite aproximadamente 2.5 cm de aislante de cada conductor. 3. Meta el cordón por el agujero de la caja y la abrazadera correspondiente. 4. Conecte los cables como sigue: Tuerza firmemente todos los hilos de cada conductor. Inserte el conductor en el agujero de amarre y enrósquelo hacia la izquierda alrededor del tornillo terminal. El conductor NEGRO al tornillo LATON, el conductor BLANCO al tornillo PLATEADO, y el conductor VERDE al tornillo hexagonal VERDE. Apriete los tornillos terminales hacia la derecha. Asegúrese de que no queden hilos sueltos. 5. Monte los tornillos de las abrazaderas. Apriete cada abrazadera NEGRA sobre cada cordón. Asegúrese de que cada cordón quede bien fijo. 6. Doble los cables cuidadosamente dentro de la caja y monte el Receptáculo Protector de Sobretensión con los cuatro tornillos #8-32 x 2.5” proporcionados. USE COPPER WIRE ON A ED GROU TORNILLO A TIERRA (VERDE) TORNILLOS PLATEADOS TORNILLOS DE LATON DETALLE DEL AGUJERO DE AGARRE HOSPITAL GRADE A B A B 15A-125V SÓLO PARA MÉXICO POLIZA DE GARANTIA: LEVITON, S.A. DE C.V., RFC LEV-920526651, ARISTA 54- A, MEXICO 11270 D.F., MEXICO Tel. 555 386 0073. Garantiza este producto por el término de un año en todas sus partes y mano de obra contra cualquier defecto de fabricación y funcionamiento a partir de la fecha de entrega o instalación del producto bajo las siguientes CONDICIONES: 1. Para hacer efectiva esta garantía, no podrán exigirse mayores requisitos que la presentación de esta póliza junto con el producto en el lugar donde fue adquirido en cualquiera de los centros de servicio que se indican a continuación. 2. La empresa se compromete a reemplazar o cambiar el producto defectuoso sin ningún cargo para el consumidor, los gastos de transportación que se deriven de su cumplimiento serán cubiertos por: LEVITON, S.A. DE C.V. 3. El tiempo de reemplazo en ningún caso será mayor a 30 días contados a partir de la recepción del producto en cualquiera de los sitios en donde pueda hacerse efectiva la garantía. 4. Cuando se requiera hacer efectiva la garantía mediante el reemplazo del producto, esto se podrá llevar a cabo en: LEVITON, S.A. DE C.V. 5. Esta garantía no es válida en los siguientes casos: A) Cuando el producto ha sido utilizado en condiciones distintas a las normales. B) Cuando el producto no ha sido operado de acuerdo con el instructivo de uso en idioma español proporcionado. C) Cuando el producto ha sido alterado o reparado por personas no autorizadas por LEVITON, S.A. DE C.V. 6. El consumidor podrá solicitar que se haga efectiva la garantía ante la propia casa comercial donde adquirió el producto. 7. En caso de que la presente garantía se extraviara el consumidor puede recurrir a su proveedor para que se le expida otra póliza de garantía previa presentación de la nota de compra o factura respectiva. Pour toute aide technique, composer le : 1 800 405-5320 (Canada seulement) www.leviton.com EXCLUSIONS ET GARANTIE LIMITÉE DE 10 ANS Leviton garantit au premier acheteur, et uniquement au crédit du dit acheteur, que ce produit ne présente ni défauts de fabrication ni défauts de matériaux au moment de sa vente par Leviton, et n’en présentera pas tant qu’il est utilisé de façon normale et adéquate, pendant une période de 10 ans suivant la date d’achat. La seule obligation de Leviton sera de corriger les dits défauts en réparant ou en remplaçant le produit défectueux si ce dernier est retourné port payé, accompagné d’une preuve de la date d’achat, avant la fin de la dite période de 10 ans, à la Manufacture Leviton du Canada Limitée, au soin du service de l’Assurance Qualité, 165 boul. Hymus, Pointe-Claire, (Québec), Canada H9R 1E9. Par cette garantie, Leviton exclut et décline toute responsabilité envers les frais de main d’oeuvre encourus pour retirer et réinstaller le produit. Cette garantie sera nulle et non avenue si le produit est installé incorrectement ou dans un environnement inadéquat, s’il a été surchargé, incorrectement utilisé, ouvert, employé de façon abusive ou modifié de quelle que manière que ce soit, ou s’il n’a été utilisé ni dans des conditions normales ni conformément aux directives ou étiquettes qui l’accompagnent. Aucune autre garantie, explicite ou implicite, y compris celle de qualité marchande et de conformité au besoin, n’est donnée, mais si une garantie implicite est requise en vertu de lois applicables, la dite garantie implicite, y compris la garantie de qualité marchande et de conformité au besoin, est limitée à une durée de 10 ans. Leviton décline toute responsabilité envers les dommages indirects, particuliers ou consécutifs, incluant, sans restriction, la perte d’usage d’équipement, la perte de ventes ou les manques à gagner, et tout dommage-intérêt découlant du délai ou du défaut de l’exé- cution des obligations de cette garantie. Seuls les recours stipulés dans les présentes, qu’ils soient d’ordre contractuel, délictuel ou autre, sont offerts en vertu de cette garantie. GARANTIA LEVITON POR DIEZ AÑOS LIMITADA Leviton garantiza al consumidor original de sus productos y no para beneficio de nadie más que este producto en el momento de su venta por Leviton está libre de defectos en materiales o fabricación por un período de diez años desde la fecha de la compra original. La única obligación de Leviton es corregir tales defectos ya sea con reparación o reemplazo, como opción, si dentro de tal período de diez años el producto pagado se devuelve, con la prueba de compra fechada y la descripción del problema a Leviton Manufacturing Co., Inc., Att.: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591, U.S.A. Esta garantía excluye y renuncia toda responsabilidad de mano de obra por remover o reinstalar este producto. Esta garantía es inválida si este producto es instalado inapropiadamente o en un ambiente inadecuado, sobrecargado, mal usado, abierto, abusado o alterado en cualquier manera o no es usado bajo condiciones de operación normal, o no conforme con las etiquetas o instrucciones. No hay otras garantías implicadas de cualquier otro tipo, incluyendo mercadotecnia y propiedad para un propósito en particular pero si alguna garantía implicada se requiere por la jurisdicción pertinente, la duración de cualquiera garantía implicada, incluyendo mercadotecnia y propiedad para un propósito en particular, es limitada a diez años. Leviton no es responsable por daños incidentales, indirectos, especiales o consecuentes, incluyendo sin limitación, daños a, o pérdida de uso de, cualquier equipo, pérdida de ventas o ganancias o retraso o falla para llevar a cabo la obligación de esta garantía. Los remedios provistos aquí son remedios exclusivos para esta garantía, ya sea basado en contrato, agravio o de otra manera. DATOS DEL USUARIO NOMBRE: DIRECCION: COL: C.P. CIUDAD: ESTADO: TELEFONO: DATOS DE LA TIENDA O VENDEDOR RAZON SOCIAL: PRODUCTO: MARCA: MODELO: NO DE SERIE: NO. DEL DISTRIBUIDOR: DIRECCION: COL: C.P. CIUDAD: ESTADO: TELEFONO: FECHA DE VENTA: FECHA DE ENTREGA O INSTALACION: Para Aistencia Técnica llame al: 1-800-824-3005 (Sólo en E.U.A.) www.leviton.com MOUNTING INSTRUCTIONS / DIRECTIVES DE MONTAGE / INSTRUCCIONES DE MONTAJE Single Gang / Boîte simple / Caja Simple Remove knockouts shown in the diagram. Mount with two #6-32 x 1-5/8” screws. Retirer les débouchures ilustrées sur le schema; fixer au moyen des deux vis 6-32 de 4,1 cm. Quite los agujeros ciegos que se muestran en el diagrama. Monte con dos tornillos #6-32 x 4.1 cm. 4” Octagon Box or Ring / Boîte ou anneau octogonal de 10,2 cm / Caja Octagonal de 10.2 cm Mount with two #8-32 x 1” screws. Fixer au moyen des deux vis 8-32 de 2,5 cm. Monte con dos tornillos #8-32 x 2.5 cm. 4” Square / Boîte carrée de 10, 2 cm / Caja Cuadrada de 10.2 cm Mount with two #8-32 x 1” screws. Fixer au moyen des deux vis 8-32 de 2,5 cm. Monte con dos tornillos #8-32 x 2.5 cm. 4” Square with Plaster Ring / Boîte carrée avec support pour plátre / Caja Cuadrada con Anillo para Yeso Remove knockouts shown in the diagram. Mount with two #6-32 x 1-5/8” screws. Retirer les débouchures ilustrées sur le schema; fixer au moyen des deux vis 6-32 de 4,1 cm. Quite los agujeros ciegos que se muestran en el diagrama. Monte con dos tornillos #6-32 x 4.1 cm. Two Gang Box / Boîte double / Caja Doble Mount the Adaptor Plate (Cat. No. 3254) to the box using two #6-32 x 7/8” screws. Wire the Receptacle as described before. Mount the Receptacle on the installed Adaptor Plate using two #8-32 x 3/4” screws. Fixer l’Adaptateur (N° de cat. 3254) à la boîte au moyen de deux vis 6-32 de 2,2 cm; raccorder la prise conformément aux directives; fixer cette dernière à l’adaptateur au moyen de deux vis 8-32 de 1,9 cm. Monte la Placa Adaptadora (No. de Cat. 3254) en la caja usando dos tornillos #6-32 x 2.2 cm. Conecte el Receptáculo como se describió anteriormente. Monte el Receptáculo en la Placa Adaptadora instalada usando dos tornillos #8-32 x 1.9 cm. 4-11/16” Square Box / Boîte carrée de 11,9 cm / Caja Cuadrada de 11.9 cm Remove the knockouts on the Adaptor Plate (Cat. No. 3254) as indicated in the diagram. Mount the Adaptor Plate to the box using two #6-32 x 7/8” screws. Wire the Receptacle as described before. Mount the Receptacle on the installed Adaptor Plate using two #8-32 x 3/4” screws. Retirer les débouchures de l’Adaptateur (N° de cat. 3254) tel qu’indiqué sur le schéma’ fixer le prise conformément aux directives; fixer cette dernière à l’adaptateur au moyen de deux vis 8-32 de 1,9 cm. Quite los agujeros ciegos de la Placa Adaptadora (No. de Cat. 3254) como se indica en el diagrama. Monte la Placa Adaptadora como se describió anteriormente. Monte el Receptá- culo en la Placa Adaptadora instalada usando dos tornillos #8-32 x 1.9 cm. PK-92695-10-02-0A

Document Preview & Text Transcription

INTRODUCTION Leviton’s Four-In-One Surge Protection Receptacles are designed to reduce the random energy surges of voltage transients and electrical noise on the power supply line. Leviton’s Four-In-One Surge Protective Receptacles can be used to protect sensitive electronic equipment in industrial, commercial, and residential locations, from the stress and degradation inflicted by voltage transients. Isolated Ground (-IG) Surge Protective Receptacles provide a pure grounding path isolated from the normal grounding means, which employs the unit’s mounting strap. The diagnostics LED indicator light is ON continuously when protection is active, but turns OFF when protection circuit is deactivated due to excessive transients. The entire unit must be replaced if surge protection is required. If the unit is not replaced, it will function only as a conventional receptacle within its given rating. Leviton’s Four-In-One Surge Protective Receptacles are UL listed to mount on a standard single wall box without an adapter plate. However, you may use the Leviton Cat. No. 3254 Adapter Plate in all applications for a more decorative look. This plate is sold separately. The Leviton Portable Box (Cat. No. 4254) can be used for surface mounting where an electrical box does not exist. The Portable Box is sold separately. FEATURES • UL 1449 TVSS rated • Impact-resistant nylon construction • 3 protection modes: L-N, L-G, N-G • Backwire ground • EMI/RFI filter for radio/TV interference INSTALLATION TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF POWER AT CIRCUIT BREAKER or fuse and test that the power is off before wiring! 1. Remove the insulation on each circuit conductor to expose 1” (2.5 cm) bare copper wire at end of circuit wire. Keep wire ends straight. 2. Connect wires as follows: Twist all strands firmly together. Insert the conductor in the snub hole and wrap the conductor counterclockwise around the terminal screw. BLACK conductor to BRASS screw, WHITE conductor to SILVER screw, and GREEN conductor to GREEN hex screw. Be sure there are no loose strands. If system ground is uninsulated, pigtail the uninsulated ground wire (which may be provided) from the GREEN hex screw to the electrical box. 3. Tighten terminal screws over wire loops using the appropriate torque value, which can be found at Leviton.com/torquevalue. 4. Mount receptacle (refer to Mounting Instructions for you application). 5. Restore power at circuit breaker or fuse. INSTALLATION IS COMPLETE. PORTABLE BOX MOUNTING USE FLEXIBLE CORD ONLY IN THIS CONFIGURATION. NEVER USE WITH UNINSULATED GROUND CONDUCTOR. A GROUND SHORT MAY OCCUR. PORTABLE BOX CONFIGURATIONS ARE NOT UL LISTED. 1. For surface mounting, remove the knockouts in the back of the box. Mount the box on the surface using #6 screws (not provided). Be sure that the box’s cord hole is oriented correctly before mounting the box. 2. Remove the cord jacket about 6” (15.2 cm). Be sure not to damage the insulation. An electrical short of current leakage may occur which may cause harm to the equipment or cause bodily injury. Remove the insulation on each conductor about 1” (2.5 cm). 3. Thread the cord through the box’s cord hole and under the strain relief clamp. 4. Connect wires as follows: Twist all strands firmly together. Insert the conductor in the snub hole and wrap the conductor counterclockwise around the terminal screw. BLACK conductor to BRASS screw, WHITE conductor to SILVER screw, and GREEN conductor to GREEN hex screw. Tighten terminal screws over wire loops using the appropriate torque value, which can be found at Leviton.com/torquevalue. Be sure there are no loose strands. 5. Mount the screws into the relief clamps. Tighten each BLACK strain relief clamp into the slot above each cord hole. Ensure that each cord is clamped tightly. 6. Fold wires carefully into box and mount the Surge Protective Receptacle with the four #8-32 x 1” long screws provided. PK-A3156-10-02-0G PK-A3156-10-02-0G Surge Protective Receptacles 15A-120VAC, 60Hz Cat. Nos. 5480 and 5480-IG (Commercial Grade), Cat. Nos. 8480 and 8480-IG (Hospital Grade) 20A-120VAC, 60Hz Cat. Nos. 5490 and 5490-IG (Commercial Grade), Cat. Nos. 8490 and 8490-IG (Hospital Grade) WARNINGS AND CAUTIONS: • TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF POWER AT CIRCUIT BREAKER or fuse and test that the power is off before wiring! • To be installed and/or used in accordance with appropriate electrical codes and regulations. • If you are unsure about any part of these instructions, contact an electrician. • This device is not a lightning arrestor. It will not survive lightning strikes in close proximity to the premises or sustained overvoltages. WARNINGS AND CAUTIONS: • Install this device only in a single branch circuit protected by a fuse or a circuit breaker. • Use this device with copper or copper-clad wire. • A surge protective receptacle will provide maximum protection for loads plugged directly into it. It will provide some protection to nearby receptacles, though protection diminishes proportionally with the length of wire run. INSTALLATION INSTRUCTIONS ENGLISH For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com LIMITED 10 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for ten years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to ten years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise. USE COPPER WIRE ONLY MADE IN U.S.A. A CAUT O I N : MOUNT N I G ED GROUND SCREW (GREEN) SILVER L SCREWS BRASS SCREWS SNUB HOLE DETAIL VIS DE M.A.L.T. (VERT) VIS VIS LAITON ORIFICE D'ANCRAGE ARGENT DETALLE DEL AGUJERO DE AGARRE TORNILLOS DE LATON TORNILLO A TIERRA (VERDE) TORNILLOS PLATEADOS MOUNTING INSTRUCTIONS / DIRECTIVES DE MONTAGE / INSTRUCCIONES DE MONTAJE Single Gang / Boîte simple / Caja Simple Remove knockouts shown in the diagram. Mount with two #6-32 x 1-5/8” screws. Retirer les débouchures ilustrées sur le schema; fixer au moyen des deux vis 6-32 de 4,1 cm. Quite los agujeros ciegos que se muestran en el diagrama. Monte con dos tornillos #6-32 x 4.1 cm. 4” Octagon Box or Ring / Boîte ou anneau octogonal de 10,2 cm / Caja Octagonal de 10.2 cm Mount with two #8-32 x 1” screws. Fixer au moyen des deux vis 8-32 de 2,5 cm. Monte con dos tornillos #8-32 x 2.5 cm. 4” Square / Boîte carrée de 10, 2 cm / Caja Cuadrada de 10.2 cm Mount with two #8-32 x 1” screws. Fixer au moyen des deux vis 8-32 de 2,5 cm. Monte con dos tornillos #8-32 x 2.5 cm. 4” Square with Plaster Ring / Boîte carrée avec support pour plâtre / Caja Cuadrada con Anillo para Yeso Remove knockouts shown in the diagram. Mount with two #6-32 x 1-5/8” screws. Retirer les débouchures ilustrées sur le schema; fixer au moyen des deux vis 6-32 de 4,1 cm. Quite los agujeros ciegos que se muestran en el diagrama. Monte con dos tornillos #6-32 x 4.1 cm. Two Gang Box / Boîte double / Caja Doble Mount the Adaptor Plate (Cat. No. 3254) to the box using two #6-32 x 7/8” screws. Wire the Receptacle as described before. Mount the Receptacle on the installed Adaptor Plate using two #8-32 x 3/4” screws. Fixer l’Adaptateur (N° de cat. 3254) à la boîte au moyen de deux vis 6-32 de 2,2 cm; raccorder la prise conformément aux directives; fixer cette dernière à l’adaptateur au moyen de deux vis 8-32 de 1,9 cm. Monte la Placa Adaptadora (No. de Cat. 3254) en la caja usando dos tornillos #6-32 x 2.2 cm. Conecte el Receptáculo como se describió anteriormente. Monte el Receptáculo en la Placa Adaptadora instalada usando dos tornillos #8-32 x 1.9 cm. 4-11/16” Square Box / Boîte carrée de 11,9 cm / Caja Cuadrada de 11.9 cm Remove the knockouts on the Adaptor Plate (Cat. No. 3254) as indicated in the diagram. Mount the Adaptor Plate to the box using two #6-32 x 7/8” screws. Wire the Receptacle as described before. Mount the Receptacle on the installed Adaptor Plate using two #8-32 x 3/4” screws. Retirer les débouchures de l’Adaptateur (N° de cat. 3254) tel qu’indiqué sur le schéma’ fixer le prise conformément aux directives; fixer cette dernière à l’adaptateur au moyen de deux vis 8-32 de 1,9 cm. Quite los agujeros ciegos de la Placa Adaptadora (No. de Cat. 3254) como se indica en el diagrama. Monte la Placa Adaptadora como se describió anteriormente. Monte el Receptá- culo en la Placa Adaptadora instalada usando dos tornillos #8-32 x 1.9 cm. HOSPITAL GRADE A B A B 15A-125V WEB VERSION INTRODUCTION Les adaptateurs quadriprises avec protecteur de surtensions de Leviton sont conçues pour réduire les crêtes d’énergie aléatoires causées par la présence de surtensions transitoires ou de bruit électrique sur les circuits d’alimentation. Ces prises peuvent protéger le matériel électronique délicat utilisé dans les applications industrielles , commerciales et résidentielles contre les contraintes et la dégradation que peuvent cause les transitoires. Les adaptateurs quadriprises avec mise à la terre isolée (-IG) assurent un parcours de M.A.L.T. isolé, distinct du trajet habituel par la bride de montage de la prise. Elles sont dotées d’in indicateur diagnostique à DEL qui reste continuellement allumé tant que la protection est assurée; il se met à clignoter et s’éteint lorsqu’il y a panne de protection en raison de la présence de surtensions excessives sur le circuit; le cas échéant, on doit remplacer le dispositif si on désire rétablir la protection du système; si le dispositif n’est pas remplacé, il ne pourra être utilisé que comme prise conventionnelle, en respectant les valeurs nominales prescrites. Les adaptateurs quadriprises avec protecteur de surtensions de Leviton s’installe dans les boîtes murales standard, sans nécessiter d’adaptateur; l’adaptateur N° de cat. 3254 peut cependant être utilisé dans toutes les applications pour obtenir une apparence plus élégante; ce adaptateur est vendu séparément. La boîte portative (N° de cat. 4254) de Leviton permet d’encastrer le adaptateur quadriprise là où il n’y a pas d’installation existant; ce dispositif est vendu séparément. CARACTÉRISTIQUES • Estimé aussi TVSS en UL 1449 • Fabrication en nylon résistant aux chocs • 3 mode de protection : L-N, L-T, N-T • Mise à la terre par raccordement arrière • Avec filtre d’interférence électromagnétique et radio fréquence DIRECTIVES POUR ÉVITER LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU D’ÉLECTROCUTION, COUPER LE COURANT au fusible ou au disjoncteur et s’assurer que le circuit soit bien coupé avant de procéder à l’installation. 1. Dénuder chacun des conducteurs afin d’exposer 2,5 cm de fil de cuivre à chaque extrémité; garder les fils bien tendus. 2. Raccorder les fils de la façon suivante : le conducteur NOIR à la vis LAITON, le conducteur BLANC à la vis ARGENT, et le fil VERT À la vis hexagonal VERT; le cas échéant, torsader le fil de M.A.L.T. qui peut être fourni entre la vis VERT et la boîte murale; insérer le conducteur dans l’orifice d’ancrage et enrouler vers la gauche sur la borne à vis. 3. Serrer les vis sur les boucles en exerçant le couple approprié, lequel se trouve sur Leviton.com/torquevalue. 4. Fixer le adaptateur (consulter les Directives d’installation du type d’application approprié). 5. Rétablir le courant au fusible ou au disjoncteur. L’INSTALLATION EST TERMINÉE. INSTALLATION DANS UNE BOÎTE PORTATIVE N’UTILISER QU DU CORDON FLEXIBLE POUR CETTE APPLICATION; NE JAMAIS UTILISER DE CONDUCTEUR DE M.A.L.T. NON ISOLÉ; CELA POURRAIT CAUSER UNE FUITE À LA TERRE; LES CONFIGURATIONS AVEC BOÎTE PORTATIVE NE SONT PAS HOMOLOGUÉES UL. 1. Pour installer en saillie, retirer les déboucheras à l’arrière de la boîte à la surface au moyen de vis 6 (non comprises) en s’assurant que l’orifice de sortie du cordon est orienté correctement. 2. Retirer du cordon environ 15 cm de gaine; s’assurer de ne pas l’endommager; cela pourrait causer un court-circuit ou une fuite de courant, endommager l’équipement ou causer des blessures; dénuder chacun des conducteurs d’environ 2,5 cm. 3. Faire passer le cordon dans l’orifice de sortie de la boîte, en le plaçant sous le brides. 4. Raccorder les fils de la façon suivante : le conducteur NOIR à la vis LAITON, le conducteur BLANC à la vis ARGENT, et le conducteur VERT à la vis hexagonale VERT; Serrer les vis sur les boucles en exerçant le couple approprié, lequel se trouve sur Leviton.com/torquevalue. S’assurer qu’aucun brin ne soit exposé. 5. S errer chaque bride noire dans les fentes au-dessus de chaque orifice de sortie; fixer au moyen de vis; s’assurer que chaque cordon soit solidement maintenu. 6. Fixer le adaptateur au moyen des quatre longues vis 8-32 de 2,5 cm comprises. AVERTISSEMENTS ET MISES EN GARDE • POUR ÉVITER LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU D’ÉLECTROCUTION, COUPER LE COURANT au fusible ou au disjoncteur et s’assurer que le circuit soit bien coupé avant de procéder à l’installation. • Installer ou utiliser conformément aux codes de l’électricité en vigueur. • À défaut de bien comprendre les présentes directives, en tout ou en partie, on doit faire appel à un électricien. • Ce dispositif n’est pas un parafoudre; il ne résistera pas aux coups de foudre à proximité des lieux qu’il protège. • Installer ce dispositif uniquement sur un circuit simple protégé par un fusible ou un disjoncteur. • N’utiliser ce dispositif qu’avec du fil de cuivre ou plaqué cuivre; en présence de fil d’aluminium, utiliser seulement les dispositifs portant la marque cu/al ou co/alr. • Les prises à dispositif limiteur de surtensions offrent une protection maximale aux charges qui leur sont directement enfichées; elles protègent cependant les prises avoisinantes, mais le niveau de protection est inversement proportionnel à la longueur du parcours de FIL. Prises à limiteur de surtensions transitoires 15 A, 120 V c.a., 60Hz N°s de cat. 5480 et 5480-IG (Qualité commerciale), N°s de cat. 8480 et 8480-IG (Qualité hôpital) 20 A, 120 V c.a., 60Hz N°s de cat. 5490 et 5490-IG (Qualité commerciale), N°s de cat. 8490 et 8490-IG (Qualité hôpital) DIRECTIVES FRANÇAIS © 2021 Leviton Mfg Co., Inc. Ligne d’Assistance Technique : 1 800 405-5320 (Canada seulement) www.leviton.com GARANTIE LIMITÉE DE 10 ANS ET EXCLUSIONS Leviton garantit au premier acheteur, et uniquement au crédit du dit acheteur, que ce produit ne présente ni défauts de fabrication ni défauts de matériaux au moment de sa vente par Leviton, et n’en présentera pas tant qu’il est utilisé de façon normale et adéquate, pendant une période de 10 ans suivant la date d’achat. La seule obligation de Leviton sera de corriger les dits défauts en réparant ou en remplaçant le produit défectueux si ce dernier est retourné port payé, accompagné d’une preuve de la date d’achat, avant la fin de la dite période de 10 ans, à la Manufacture Leviton du Canada Limitée, au soin du service de l’Assurance Qualité, 165 boul. Hymus, Pointe-Claire, (Québec), Canada H9R 1E9. Par cette garantie, Leviton exclut et décline toute responsabilité envers les frais de main d’oeuvre encourus pour retirer et réinstaller le produit. Cette garantie sera nulle et non avenue si le produit est installé incorrectement ou dans un environnement inadéquat, s’il a été surchargé, incorrectement utilisé, ouvert, employé de façon abusive ou modifié de quelle que manière que ce soit, ou s’il n’a été utilisé ni dans des conditions normales ni conformément aux directives ou étiquettes qui l’accompagnent. Aucune autre garantie, explicite ou implicite, y compris celle de qualité marchande et de conformité au besoin, n’est donnée, mais si une garantie implicite est requise en vertu de lois applicables, la dite garantie implicite, y compris la garantie de qualité marchande et de conformité au besoin, est limitée à une durée de 10 ans. Leviton décline toute responsabilité envers les dommages indirects, particuliers ou consécutifs, incluant, sans restriction, la perte d’usage d’équipement, la perte de ventes ou les manques à gagner, et tout dommage-intérêt découlant du délai ou du défaut de l’exécution des obligations de cette garantie. Seuls les recours stipulés dans les présentes, qu’ils soient d’ordre contractuel, délictuel ou autre, sont offerts en vertu de cette garantie. PK-A3156-10-02-0G INSTRUCCIONES DE INSTALACIÓN ESPAÑOL Receptáculos Protectores de Sobretensión 15A-120VCA, 60Hz Nos. de Cat. 5480 y 5480-IG (Calidad Comercial), Nos. de Cat. 8480 y 8480-IG (Calidad Hospital) 20A-120VCA, 60Hz Nos. de Cat. 5490 y 5490-IG (Calidad Comercial), Nos. de Cat. 8490 y 8490-IG (Calidad Hospital) ADVERTENCIAS Y PRECAUCIONES • PARA EVITAR DESCARGA ELECTRICA, FUEGO, O MUERTE, INTERRUMPA EL PASO DE ENERGIA mediante el interruptor de circuito o fusible. ¡Asegurese de que el circuito no este energizado antes de iniciar la instalacion! • Para instalarse y/o usarse de acuerdo con los codigos electricos y normas apropiados. • Si usted no esta seguro acerca de alguna parte de estas instrucciones, consulte a un electricista calificado. • Este producto no es un pararrayos. No sobrevivira los relampagos en proximidad con las premisas. • Instale este producto solo en un circuito protegido por un fusible o interruptor de circuitos. • Use este producto solo con cable de cobre o revestido de cobre. Para cable de aluminio use solo productos marcados con el simbolo co/alr o cu/al. • Un receptaculo protector de sobretension proporcionara proteccion maxima a cargas conectadas directamente en el. Proporcionara alguna proteccion a receptaculos adyacentes, aunque la proteccion disminuye proporcionalmente con la longitud del cableado. GARANTIA LIMITADA POR DIEZ AÑOS Y EXCLUSIONES Leviton garantiza al consumidor original de sus productos y no para beneficio de nadie más que este producto en el momento de su venta por Leviton está libre de defectos en materiales o fabricación por un período de diez años desde la fecha de la compra original. La única obligación de Leviton es corregir tales defectos ya sea con reparación o reemplazo, como opción. Para detalles visite www.leviton.com o llame al 1-800-824-3005. Esta garantía excluye y renuncia toda responsabilidad de mano de obra por remover o reinstalar este producto. Esta garantía es inválida si este producto es instalado inapropiadamente o en un ambiente inadecuado, sobrecargado, mal usado, abierto, abusado o alterado en cualquier manera o no es usado bajo condiciones de operación normal, o no conforme con las etiquetas o instrucciones. No hay otras garantías implicadas de cualquier otro tipo, incluyendo mercadotecnia y propiedad para un propósito en particular pero si alguna garantía implicada se requiere por la jurisdicción pertinente, la duración de cualquiera garantía implicada, incluyendo mercadotecnia y propiedad para un propósito en particular, es limitada a diez años. Leviton no es responsable por daños incidentales, indirectos, especiales o consecuentes, incluyendo sin limitación, daños a, o pérdida de uso de, cualquier equipo, pérdida de ventas o ganancias o retraso o falla para llevar a cabo la obligación de esta garantía. Los remedios provistos aquí son remedios exclusivos para esta garantía, ya sea basado en contrato, agravio o de otra manera. Para Asistencia Técnica llame al: 1-800-824-3005 (Sólo en EE.UU.) www.leviton.com SÓLO PARA MÉXICO POLIZA DE GARANTIA: Leviton S de RL de CV, Lago Tana No. 43, Col. Huichapan, Del. M. Hidalgo, Ciudad de México, CP 11290 México. Tel +52 (55) 5082-1040. Garantiza este producto por el término de diez años en todas sus partes y mano de obra contra cualquier defecto de fabricación y funcionamiento a partir de la fecha de entrega o instalación del producto bajo las siguientes CONDICIONES: 1. Para hacer efectiva esta garantía, no podrán exigirse mayores requisitos que la presentación de esta póliza junto con el producto en el lugar donde fue adquirido en cualquiera de los centros de servicio que se indican a continuación. 2. La empresa se compromete a reemplazar o cambiar el producto defectuoso sin ningún cargo para el consumidor, los gastos de transportación que se deriven de su cumplimiento serán cubiertos por: Leviton S de RL de CV 3. El tiempo de reemplazo en ningún caso será mayor a 30 días contados a partir de la recepción del producto en cualquiera de los sitios en donde pueda hacerse efectiva la garantía. 4. Cuando se requiera hacer efectiva la garantía mediante el reemplazo del producto, esto se podrá llevar a cabo en: Leviton S de RL de CV 5. Esta garantía no es válida en los siguientes casos: A) Cuando el producto ha sido utilizado en condiciones distintas a las normales. B) Cuando el producto no ha sido operado de acuerdo con el instructivo de uso en idioma español proporcionado. C) Cuando el producto ha sido alterado o reparado por personas no autorizadas por Leviton S de RL de CV 6. El consumidor podrá solicitar que se haga efectiva la garantía ante la propia casa comercial donde adquirió el producto. 7. En caso de que la presente garantía se extraviara el consumidor puede recurrir a su proveedor para que se le expida otra póliza de garantía previa presentación de la nota de compra o factura respectiva. DATOS DEL USUARIO NOMBRE: DIRECCION: COL: C.P. CIUDAD: ESTADO: TELEFONO: DATOS DE LA TIENDA O VENDEDOR RAZON SOCIAL: PRODUCTO: MARCA: MODELO: NO DE SERIE: NO. DEL DISTRIBUIDOR: DIRECCION: COL: C.P. CIUDAD: ESTADO: TELEFONO: FECHA DE VENTA: FECHA DE ENTREGA O INSTALACION: INTRODUCCIÓN Los Receptáculos Cuatro-En-Uno Protectores de Sobretensión de Leviton están diseñados para reducir las sobretensiones aleatorias de energía y el ruido eléctrico en las líneas de alimentación de energía. Los Receptáculos Cuatro-En-Uno Protectores de Sobretensión de Leviton pueden usarse para proteger equipo electrónico sensitivo en ubicaciones industriales, comerciales y residenciales, de la presión u degradación infligida por descargas de voltaje. Los Receptáculos Cuatro-En-Uno Protectores de Sobretensión con Tierra Aislada (-IG) proporcionan una ruta de aterrizado pura, aislada de los medios normales de aterrizado que emplean el bastidor de montaje de la unidad. La luz indicadora de diagnósticos DEL (Diodo Emisor de Luz) se ENCIENDE continuamente cuando la protección está activa, pero se APAGA cuando el circuito de protección es desactivado debido a transientes excesivos. La unidad completa debe ser reemplazada si se desea protección de sobretensión. Si la unidad no es reemplazada, funcionará solamente como un receptáculo convencional dentro de su capacidad dada. Los Receptáculos Cuatro-En-Uno Protectores de Sobretensión están catalogados por UL para montarse en una caja de pared sencilla estándar, sin placa adaptadora. Sin embargo, usted puede usar la Placa Adaptadora Leviton No. de Cat. 3254 en todas las aplicaciones para dar un toque más decorativo. Esta placa se vende por separado. La Caja Portátil de Leviton (No. de Cat. 4254) puede ser usada con el Receptáculo Protector de Sobretensión para montaje superficial en donde no exista una caja eléctrica. La Caja Portátil se vende por separado. CARACTERÍSTICAS • Clasificado en UL 1449 como TVSS • Construcción de nylon resistente al impacto • 3 modos de protección: L-N, L-T, N-T • Cableado a tierra posterior • Con filtro de interferencia electromagnética y radio frecuencia INSTRUCCIONES DE INSTALACIÓN PARA EVITAR DESCARGA ELÉCTRICA, FUEGO, O MUERTE, INTERRUMPA EL PASO DE ENERGÍA mediante el interruptor de circuito o fusible. ¡Asegúrese de que el circuito no esté energizado antes de iniciar la instalación! 1. Quite el aislante en cada conductor para exponer 2.5 cm de alambre de cobre desnudo en cada extremo de los cables del circuito. Mantenga las puntas de los alambres rectas. 2. Conecte los cables como sigue: Tuerza firmemente todos los hilos de cada conductor. Inserte el conductor en el agujero de amarre y enrósquelo hacia la izquierda alrededor del tornillo terminal. El conductor NEGRO al tornillo LATON, el conductor BLANCO al tornillo PLATEADO, y el conductor VERDE al tornillo hexagonal VERDE. Asegúrese de que no haya hilos sueltos. Si el sistema a tierra está sin aislar, conecte el cable de tierra aislada (puede que no se incluya) del tornillo hexagonal VERDE a la caja eléctrica de la pared. 3. Apriete los tornillos de las terminales sobre los bucles de los cables utilizando el valor de torque apropiado, que puede encontrarse en Leviton.com/torquevalue. 4. Monte el receptáculo (vea las Instrucciones de Montaje para su aplicación). 5. Restablezca la energía mediante el interruptor de circuito o fusible. LA INSTALACIÓN ESTA TERMINADA. MONTAJE EN CAJA PORTATIL EN ESTA CONFIGURACIÓN, USE SOLO CORDÓN FLEXIBLE. NUCA USE CONDUCTOR A TIERRA SIN AISLANTE. UN CORTO A TIERRA PUEDE OCURRIR. LAS CONFIGURACIONES DE LA CAJA PORTATIL NO ESTAN CATALOGADAS POR UL. 1. Para montaje superficial, quite los agujeros ciegos en la parte posterior de la caja. Monte la caja en la superficie usando tornillos #6 (no incluidos). Asegúrese de que el agujero de la caja para el cordón esté correctamente orientado antes de montar la caja. 2. Quite aproximadamente 15.5 cm de forro del cordón. Asegúrese de no dañar el aislante. Un corto eléctrico o falla de corriente puede ocurrir, el cual pudiera causar daños a la salud. Quite aproximadamente 2.5 cm de aislante de cada conductor. 3. Meta el cordón por el agujero de la caja y la abrazadera correspondiente. 4. Conecte los cables como sigue: Tuerza firmemente todos los hilos de cada conductor. Inserte el conductor en el agujero de amarre y enrósquelo hacia la izquierda alrededor del tornillo terminal. El conductor NEGRO al tornillo LATON, el conductor BLANCO al tornillo PLATEADO, y el conductor VERDE al tornillo hexagonal VERDE. Apriete los tornillos de las terminales sobre los bucles de los cables utilizando el valor de torque apropiado, que puede encontrarse en Leviton. com/torquevalue. Asegúrese de que no queden hilos sueltos. 5. Monte los tornillos de las abrazaderas. Apriete cada abrazadera NEGRA sobre cada cordón. Asegúrese de que cada cordón quede bien fijo. 6. Doble los cables cuidadosamente dentro de la caja y monte el Receptáculo Protector de Sobretensión con los cuatro tornillos #8-32 x 2.5” proporcionados. WEB VERSION