LEYBOLD RUVAC WS 251 Manuals

2 pdf manual(s) LEYBOLD RUVAC WS 251 for free download (Document Types: Installation and operating instructions manual, Operating instructions manual)

Available Documents for RUVAC WS 251:

LEYBOLD RUVAC WS 251 Installation and operating instructions manual Main Page Preview

Installation and operating instructions manual [PDF] (52 pages)

  • Brand: LEYBOLD
  • Model: RUVAC WS 251
  • Format: PDF
  • Key Aspects: Safety Recommendations and Warnings, Manufacturer Contact and Support Data, Initial Startup Checklist
  • Updated: 21.07.2026
  • Source File: 1933844.pdf
  • Pages: 52
  • Description: Technical operations guide for the LEYBOLD RUVAC WS 251.

Document Preview & Text Transcription

Part Numbers 155007 155009 155042 155043 155053 155054 155066 155110 155111 155112 155113 155114 167007 167026 167042 167043 167044 167056 167097 167129V 167173V 167175V 167187V 167190V 7850009 7850010 20003123 7850011V 11375 11722 11723 11727 11728 11732 11733 11737 11738 11742 11743 11747 11752 11753 11757 11833 11843 11853 12860 15047 15095 15096 RUVAC WS / WSU 251/501/1001/2001 Roots vacuum pump with mineral oil, synthetic oil or PFPE-filling Installation and Operating Instructions GA 03108_002_C1 Contents 2 GA03108_002_C1 - 04/2018 - ' Leybold Page 0 Important Safety Information 5 0.1 Mechanical Hazards 5 0.2 Electrical Hazards 6 0.3 Thermal Hazards 7 0.4 Hazards Caused by Materials and Substances 7 0.5 Ignition Risk 9 0.6 Noise Hazard 9 0.7 Danger of Pump Damage 10 1 Description 11 1.1 Design and Function 11 1.1.1 Principle of Operation 11 1.1.2 Design 13 1.1.3 Pressure Balance Line 14 1.1.4 Lubricants 15 1.2 Standard Specification 15 1.3 Technical Data 17 1.3.1 Voltage ranges for the canned motors 18 1.3.2 Limitations of use for frequency converter operation 19 1.3.3 Maximum Pressure Difference 20 1.4 Ordering Information 22 1.4.1 Pumps 22 1.4.2 Accessories 24 2 Transport and Storage 25 3 Installation 27 3.1 Installation 27 3.1.1 Filling in of the Lubricants 28 3.2 Conforming Utilisation 30 3.2.1 Non-conforming Utilisation 30 3.3 Connecting the Cooling Water 32 3.3.1 Water Quality 32 3.4 Electrical Connection 33 3.5 Connecting the Flanges 36 Contents 3 GA03108_002_C1 - 04/2018 - ' Leybold These Installation and Operating Instructions are the original instructions. 4 Operation 37 4.1 Start-up 37 4.2 Operation 38 4.3 Shutdown and Storage 39 4.4 Changing from Vertical to Horizontal Flow 39 5 Maintenance 40 5.1 Safety Information 40 5.2 Exchanging the Lubricant 41 5.3 Cleaning the Fan Cowl and the Cooling Fins 42 5.4 Cleaning the Intake Screen 43 5.5 Cleaning the Pumping Chamber 43 5.6 Cleaning the Valve of the Pressure Balance Line 44 5.7 Service at Leybold 45 5.8 Maintenance Schedule 46 6 Troubleshooting 47 7 Wearing and Original Spare Parts 49 8 Waste Disposal 49 EC Declaration of Conformity 50 Declaration of Contamination 51
LEYBOLD RUVAC WS 251 Operating instructions manual Main Page Preview

Operating instructions manual [PDF] (26 pages)

  • Brand: LEYBOLD
  • Model: RUVAC WS 251
  • Format: PDF
  • Key Aspects: Risk Mitigation and Accident Prevention, Standard Operating Procedures, Efficiency and Calibration Tips
  • Updated: 27.04.2026
  • Source File: 1396296.pdf
  • Pages: 26
  • Description: Technical setup manual for the LEYBOLD RUVAC WS 251.

Document Preview & Text Transcription

RUVAC WS/WSU 251/501/1001/2001 Roots pump with mineral oil, synthetic oil or PFPE filling Cat.-No. 101 83 117 22/32/42/52 117 23/33/43/53 117 27/37/47/57 117 28/38 118 33/43/53 150 44/95/96 167 007 917 48 155 000 Operating Instructions GA 03.108/14.02 Vacuum Solutions Application Support Service LEYBOLD VACUUM Contents Contents Page IMPORTANT SAFETY CONSIDERATIONS . .4 1 Description . . . . . . . . . . . . . . . . . . . . . . . . . .6 1.1 Design and function . . . . . . . . . . . . . . . . . . . .6 1.2 Standard specification . . . . . . . . . . . . . . . . . .9 1.3 Technical data . . . . . . . . . . . . . . . . . . . . . . .10 1.4 Accessories . . . . . . . . . . . . . . . . . . . . . . . . .11 2 Transportation and storage . . . . . . . . . . . .12 3 Installation and connection . . . . . . . . . . . .13 3.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . .13 3.2 Filling in of the lubricants . . . . . . . . . . . . . . .13 3.3 Electrical connections . . . . . . . . . . . . . . . . . .14 3.4 Connection of the flanges . . . . . . . . . . . . . . .16 4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . .17 4.1 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 4.2 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . .17 4.3 Shutdown and storage . . . . . . . . . . . . . . . . .18 4.4 Changing from vertical to horizontal flow . . . .18 5 Maintenance . . . . . . . . . . . . . . . . . . . . . . . .19 5.1 Safety information . . . . . . . . . . . . . . . . . . . . .19 5.2 Exchanging the lubricants . . . . . . . . . . . . . . .19 5.3 Cleaning the fan cowl and the cooling fins . .20 5.4 Cleaning the dirt trap . . . . . . . . . . . . . . . . . .20 5.5 Cleaning the pumping chamber . . . . . . . . . .21 5.6 Cleaning the valve of the pressure balance line . . . . . . . . . . . . . . . . . . . . . . . . .21 5.7 Leybold service . . . . . . . . . . . . . . . . . . . . . .22 6 Troubleshooting . . . . . . . . . . . . . . . . . . . . .23 EEC Declaration of Conformity . . . . . . . . .24 Indicates procedures that must be strictly observed to prevent hazards to persons. Indicates procedures that must strictly be observed to prevent damage to, or destruc- tion of the equipment. Figures The references to figures, e.g. (1/2) consist of the Fig. No. and the Item No. in that order. 2 GA 03.108/14.02 - 01/03 Warning Caution Contents Leybold-Service If a pump is returned to Leybold, indicate whether the pump free of substances damaging to health or whether it is contaminated. If it is contaminated also indicate the nature of the hazard. Leybold must return any pumps without a „Declaration of Contamination“ to the sender’s address. Disposal of waste oil Under the amended law relating to waste disposal dated November 1, 1986 (valid in the Federal Republic of Ger- many) the disposal of used oil is subject to new provi- sions. According to legislation relating to waste disposal the so-called principle of causality is applied. Hence, anyone in possession of used oil is responsible for its proper disposal. Used oils coming from vacuum pumps must not be mixed with other substances. Used oils from vacuum pumps (LH-oils on the basis of mineral oils) having been affected by normal contamina- tion due to oxygen from the ambient air, increases in temperature and mechanical wear, must be disposed of as used oil in accordance with the regulations. Used oils from vacuum pumps that have been contami- nated by other substances must be labelled, stored and disposed of as special waste with reference to the kind of contamination. If you send a pump to LEYBOLD for repair please indi- cate any harmful substances existing in the pump oil or around the pump. When disposing of used oil please observe the safety regulations that are valid in your country. We reserve the right to modify the design and the speci- fied data. The illustrations are not binding. 3 GA 03.108/14.02 - 01/03 4 GA 03.108/14.02 - 01/03 Safety considerations IMPORTANT SAFETY CONSIDERATIONS The Leybold RUVAC vacuum pump is designed for safe and efficient operation when used properly and in accordance with this manual. It is the responsibility of the user to carefully read and strictly observe all safety precautions described in this section and throughout the manual. This product must be ope- rated and maintained by trained personnel only. Consult local, state, and national agencies regarding specific requirements and regulations. Address any further safety, operation and/or maintenance que- stions to your nearest Leybold Vacuum office. Warning Failure to observe the following precautions could result in serious personal injury. • Before beginning with any maintenance or service work on the RUVAC, disconnect the pump from all power supplies. • Do not operate the pump with any of the covers removed. Serious injury may result. • If exhaust gases must be collected or contained, do not allow the exhaust line to become pressurized. • Make sure that the gas flow from the exhaust port is not blocked or restricted in any way. • The standard version of the RUVAC is not suited for operation in explosion hazard areas. Contact us before planning to use the pump under such circumstances. • Before starting up for the first time, the motor circuit must be equipped with a suitable protective motor switch. Please take note of the information in these Operating Instructions or on the electric motor (wiring diagram). • The RUVAC is not suited for pumping of - combustible and explosive gases or vapours - radioactive and toxic substances - pyrophorous substances. • The RUVAC must be integrated in the system control arrangement so that the pump can not run-up automatically after it has been shut down by the temperature switches in the motor. This applies equally to emergency shut-down arrangements. After having determined the fault cause, the pump should be switched on manually again. • Avoid exposing any part of the human body to the vacuum. • Never operate the RUVAC without a connected intake line or blank flange. • The location at which the RUVAC (including its accessories) is operated should be such that angles over 10° from the vertical are avoided. • The location of the RUVAC should be such that all controls are easily accessible. • Under certain ambient conditions the RUVAC may attain a temperature of over 80 °C (176 °F). There then exists the danger of receiving burns. Note the symbols on the pump pointing to the hazards, and in the case of a hot pump wear the required protective clothing.

RUVAC WS 251: Related Instructions

Manuals from Other Manufacturers