LOVATO ELECTRIC DCRM 2 Manuals
1 pdf manual(s) LOVATO ELECTRIC DCRM 2 for free download (Document Types: Manual )
LOVATO ELECTRIC DCRM 2 Manual [PDF] (6 pages)
- Identifier: id-1928143
- Brand: LOVATO ELECTRIC
- Device: DCRM 2 Relays
- Type: PDF
- Key Aspects: Component Overview and Descriptions, Safety Recommendations and Warnings, Common Issue Diagnostic Flows
- UPD Date: 04.06.2026
- Source File: 2359853.pdf
- Pages: 6
- Description: Complete instruction guide for the LOVATO ELECTRIC DCRM 2.
Click to expand and read text
MHIT200D0207.doc 17/10/2011 Page 1/6 RELE’ PER IL CONTROLLO REACTIVE CURRENT DELLA CORRENTE REATTIVA CONTROLLER RELAY DCRM 2 DCRM 2 S2 A2 L1/L A1 L2/N S1 21 11 12 14 22 24 DCRM 2 ON System configuration C/K step 1 Disconnection delay [sec] C/K step 2 1 20 60 40 40 20 1 60 3ph 1ph Connection delay [sec] 1 2 0.5 Off 1.5 2 1 0.15 0.5 Off 1.5 2 1 0.15 Lovato R Schema di collegamento trifase con inserzione mediante TA Wiring diagram for three phase with CT connection 480V 5A A1 A2 S1 L2 L3 L1 L1/L S2 L2/N O A D L 22 14 12 11 24 21 Step 2 Step 1 ATTENZIONE! Leggere attentamente il manuale prima dell’utilizzo e l’installazione. ● Questi apparecchi devono essere installati da personale qualificato, nel rispetto delle vigenti normative impiantistiche, allo scopo di evitare danni a persone o cose. ● Prima di qualsiasi intervento, rimuovere tutte le tensioni pericolose dall’apparecchio. ●Il costruttore non si assume responsabilità in merito alla sicurezza elettrica in caso di utilizzo improprio del dispositivo. ● I prodotti descritti in questo documento sono suscettibili in qualsiasi momento di evoluzioni o modifiche. Le descrizioni ed i dati a catalogo non possono pertanto avere alcun valore contrattuale. ● Un interruttore magnetotermico va compreso nell’impianto elettrico dell’edificio. Esso deve trovarsi in stretta vicinanza dell’apparecchio ed essere facilmente raggiungibile da parte dell’operatore. Deve essere marchiato come il dispositivo di interruzione dell’apparecchio: IEC/ EN 61010-1 § 6.11.2.1 ● Installare lo strumento in contenitore e/o quadro elettrico con grado di protezione minimo IP40. ● Pulire lo strumento con panno morbido, non usare prodotti abrasivi, detergenti liquidi o solventi. Descrizione • Il DCRM2 consente di controllare la corrente reattiva di un impianto, eliminandola dal totale richiesto al fornitore di energia e quindi rifasando il carico al migliore cosfi possibile. • Esso è in grado di controllare la connessione di max 2 banchi di condensatori. • Ciascuno dei due banchi di condensatori può essere abilitato singolarmente e la sua potenza può essere definita tramite un trimmer dedicato. • E’ inoltre possibile regolare il tempo di inserzione e disinserzione dei condensatori, aggiustando quindi la velocità di reazione del sistema. • L’apparecchio è utilizzabile sia in configurazione trifase che monofase. Caratteristiche • Inserzione mediante TA esterno con secondario /5A. • Riconoscimento automatico del senso di collegamento del TA (diretto / inverso). • Possibilità di abilitare singolarmente il controllo dei due relè (Posizione OFF). • Regolazione soglie di C/K da 0.15 a 2.00. • Ritardo alla connessione delle capacità 1..60 sec. • Ritardo alla disconnessione delle capacità 1..60 sec. • Tempo di riconnessione fisso 60 sec. • Impostazione della configurazione del sistema: 3ph / 1ph. • Uscite a relè con contatto in scambio. • LED verde di segnalazione alimentazione e durata inibizione. • 1 LED rosso di segnalazione inserzione relè 1. • 1 LED rosso di segnalazione inserzione relè 2. WARNING! Carefully read the manual before the installation or use. ● This equipment is to be installed by qualified personnel, complying to current standards, to avoid damages or safety hazards. ● Remove the dangerous voltage from the product before any maintenance operation on it. ● Technical data and descriptions in the publication are accurate, to the best of our knowledge, but no liabilities for errors, omissions or contingencies arising therefrom are accepted. ●Products illustrated herein are subject to alteration and changes without prior notice. ● A circuit breaker must be included in the electrical installation of the building. It must be installed close by the equipment and within easy reach of the operator. It must be marked as the disconnecting device of the equipment: IEC /EN 61010-1 § 6.11.2.1 ● Fit the instrument in an enclosure or cabinet with minimum IP40 degree protection. ● Clean the instrument with a soft dry cloth, do not use abrasives, liquid detergents or solvents Description • The DCRM2 allows to control the reactive current of a plant, eliminating it from the total current drawn from the mains and correcting the cos-phi of the load to the best possible value. • It can control the connection of maximum 2 banks of capacitors. • Each one of the two capacitor banks can be individually enabled and its power can be set through a dedicated trimmer. • It is also possible to adjust the time for connection and disconnection of the capacitors, modifying the reaction speed of the system. • The device can be used both in single-phase and three-phase wiring. Characteristics • Connection by external CT with 5A secondary. • Automatic recognition of CT polarity (direct / reverse). • Capability to individually enable the control of the two relays (OFF position). • C/K threshold adjustment from 0.15 to 2.00. • Connection delay for the steps adjustable from1 to 60 sec. • Disconnection delay for the steps adjustable from1 to 60 sec. • Reconnection time fixed to 60sec. • Selectable wiring configuration 3ph / 1ph. • Output relays each with changeover contact. • Green LED indictor for power on and inhibition time. • Red LED indicator for C/K1 tripping relay. • Red LED indicator for C/K2 tripping relay. I327 I GB 10 11 31100154 1 2 3 4 5
DCRM 2: Related Instructions
I141 I GB PL 10 11 31100027 ATTENZIONE! Questi apparecchi devono essere installati da personale qualificato, nel rispetto delle vigenti normative impiantistiche Operation guide for the LOVATO ELECTRIC DCRK5 Controller. The document covers connectivity options, system setup, functional overview, backup procedures.
I468 GB I F D E 01 17 31100281 1 – Carefully read the manual before the installation or use. – This equipment is to be installed by qualified personnel, c User guide for the LOVATO ELECTRIC LVFS W Series Switch. The document offers guidance on software installation, technical specifications, replacement parts.
obowiązując ● Przed prac i zasilania po ● Produkty z ulepszone be ● Dane tech wiedzę, jedn nie bierzemy ● W układzie niedaleko urz i być łatwo d 6 Full operation manual for the LOVATO ELECTRIC FFL DP Series Controller. This guide presents setup, operating modes, system parameters, safety protocols.
Doc: I287PLGB0110_EXP1000 22/01/2010 s. 1 / 4 PL EXP10 00 EXP10 00 Moduł rozszerz Reference manual for the LOVATO ELECTRIC EXP10 00 Measuring Instruments. It offers details on service procedures, product handling, firmware updates.
I297 GB I 01 15 31100147 1 LOVATO ELECTRIC S.P.A. 24020 GORLE (BERGAMO) ITALIA VIA DON E. MAZZA, 12 TEL. 035 4282111 FAX (Nazionale): 035 4282200 FAX (Internati Installation reference manual for the LOVATO ELECTRIC EXP10 14 Recording Equipment. This documentation explains configuration and product specifications, power management, security instructions.
Doc: MHIT101A0508_EXP1011 02/11/2009 s. 1 / 3 PL EXP10 11 EXP10 11 Moduł rozszerzeń Practical operating guide for the LOVATO ELECTRIC EXP10 11 Measuring Instruments. It offers guidance for setup and replacement parts, specifications, user instructions.
Similar Manuals in the Relays Category
1 s Operating Instructions Automatic Power Factor Controller Relay 7UG0571-1FT20 7UG0572-1GT20 7UG0 IEC 60947-5-1 Please read and understand these instructions Product usage manual for the Siemens 7UG0571-1FT20 Relays. It explains maintenance and safety guidelines, performance details, network configuration, device instructions.
GUÍA INICIO RÁPIDA QUICK START GUIDE GUIDE DE MISE EN MARCHE RAPIDE SCHNELLSTARTANLEITUNG GUIA DE INICIAÇÃO RAPIDA KIT AUDIO DUOX PLUS CITYLINE 1-2 L DUOX P Complete user documentation for the Fermax DUOX PLUS Telephone. The documentation guides users through setup and operational guidelines, operational safety, setup instructions, reset instructions.
INSTRUCTION MANUAL TSUBAKI TSUBAKI TSUBAKI TSUBAKI EEEE& & & &MMMM CO. CO. CO. CO. WARNING WARNING WARNIN� Product instruction manual for the Tsubaki TSBSU Series Relays. The document guides users through operational safety, power requirements, installation.
MODEL LUT-SHUNT-FM INSTALLATION INSTRUCTIONS 1 LVS LVS, Inc. 2555 Nicholson Street, San Leandro, CA 94577-4216 Phone: 510-352-9600 1-800-982-4587 Fax: 51 Complete technical documentation for the LVS LUT-SHUNT-FM Relays. It offers guidance on safety, user instructions, setup instructions.