Lutron Electronics Maestro MS-OPS6-DDV Manuals

4 pdf manual(s) Lutron Electronics Maestro MS-OPS6-DDV for free download (Document Types: Manual )

Lutron Electronics Maestro MS-OPS6-DDV Manual  Thumbnail

Lutron Electronics Maestro MS-OPS6-DDV Manual  [PDF] (8 pages)

  • Identifier: id-1498181
  • Brand: Lutron Electronics
  • Device: Lutron Electronics Maestro MS-OPS6-DDV Switch
  • Type: Manual , PDF
  • Key Aspects: Technical Support and Resource Links, Glossary of Technical Terms, Documentation and Revision History
  • UPD Date: 15.06.2026
  • Source File: 1500248.pdf
  • Pages: 8
  • Description: Complete usage guide for the Lutron Electronics Maestro MS-OPS6-DDV.
Pages Preview:
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 2
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 3
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 4
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 5
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 6
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 7
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 8
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Important Notes Please read before installing. 1. Device will not function if it is not grounded. Both bare and green ground wires are required to connect to ground. If no ground is available, consult an electrician. 2. Device will not function if Black wires (Circuit 1/Line 1) are not wired. 3. This product is rated to control 6 A per circuit. Circuits may NOT be wired in parallel to control loads greater than 6 A. 4. CAUTION: Risk of Electric Shock — More than one disconnect switch may be required to de-energize the equipment before installing the unit, rewiring, or replacing bulbs. 5. When power is applied, the dual- circuit sensing switch can be manually turned on or off after 60 seconds and will automatically control the load after 2 minutes. 6. The dual-circuit sensing switch requires an unobstructed view of the room and line-of-sight to detect motion. 7. Hot objects or moving air currents can affect the performance of the dual-circuit sensing switch and may cause the sensor to turn on unexpectedly or maintain its current state longer than desired. 8. CAUTION: To reduce the risk of overheating and possible damage to other equipment, DO NOT use to control receptacles. 9. Install in accordance with all national and local electrical codes. 10. For indoor use only. Operate between 32 °F and 104 °F (0 °C and 40 °C). 11. DO NOT exceed 20 devices at 120 V~ or 7 devices at 277 V~ on a single branch circuit. 12. Clean with a soft damp cloth only. DO NOT use any chemical cleaners. Wiring NOTE: Leave wallplate off if custom settings are desired. See Custom Settings instructions on reverse side. 1 Device will not function if Black wires (Circuit 1/ Line 1) are not wired. 2 Device will not function if it is not grounded. Black1 Green Bare Black-Orange Neutral Load 1 Load 2 120-277 V~ Black Black-Orange Ground2 A. Single-Line Wiring B. Two-Line Wiring Black1 Green Ground2 Bare Black-Orange Neutral 2 Line 1 Load 1 Load 2 Line 2 120-277 V~ Neutral 1 Black Black-Orange 120-277 V~ 2 Connect dual-circuit sensing switch WARNING! Shock Hazard. May result in serious injury or death. Turn power OFF at circuit breaker(s) before installing the unit, rewiring, or replacing bulbs. 1 Turn power OFF A. I I I O O O Single-Line I I I O O O B. Two-Line* ® Dual-Circuit Occupancy Sensing Switch P/N 032444 Rev. A 11/2013 MS-OPS6-DDV Occupancy MS-PPS6-DDV Partial-ON only Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 U.S.A. www.lutron.com ® Single-pole only Two circuits, each rated at: Circuit 1 Tap Button Top programming button Bottom programming button Circuit 2 Tap Button Limited Warranty (Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean). Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within five years after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid. This warranty is in lieu of all other express warranties, and the implied warranty of merchantability is limited to FIVE years from purchase. This warranty does not cover the cost of installation, removal or reinstallation, or damage resulting from misuse, abuse, or damage from improper wiring or installation. This warranty does not cover incidental or consequential damages. Lutron’s liability on any claim for damages arising out of or in connection with the manufacture, sale, installation, delivery, or use of the unit shall never exceed the purchase price of the unit. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you. Lutron and Maestro are registered trademarks of Lutron Electronics Co., Inc. © 2013 Lutron Electronics Co., Inc. Major motion coverage: 30 ft × 30 ft (9 m × 9 m) [900 ft2 (81 m2)] Minor motion coverage: 20 ft × 20 ft (6 m × 6 m) [400 ft2 (36 m2)] * Wiring must comply with NEC code for wiring Multiple Branch Circuits: Where two or more branch circuits supply devices or equipment on the same yoke, a means to simultaneously disconnect the ungrounded conductors supplying those devices shall be provided at the point at which the branch circuits originate. OR 3 Turn Power ON OR I I I O O O A. I I I O O O B. 4 Wait for 60 seconds before manual switching • The sensing switch will not manually control the load for 60 seconds. 5 Wait for an additional 60 seconds for automatic switching • Once power has been restored, the sensing switch will not automatically control the load for the first 2 minutes. 60 s 60 s Lighting (incandescent, halogen, CFL, LED, ELV, MLV, electronic fluorescent, magnetic fluorescent) 120-277 V~ 50 / 60 Hz 6 A Fan 120 V~ 50 / 60 Hz 4.4 A 1/6 HP Combined lighting and fan load 120 V~ 50 / 60 Hz 4.4 A English
Lutron Electronics Maestro MS-OPS6-DDV Manual  Thumbnail

Lutron Electronics Maestro MS-OPS6-DDV Manual  [PDF] (14 pages)

  • Identifier: id-1605163
  • Brand: Lutron Electronics
  • Device: Lutron Electronics Maestro MS-OPS6-DDV Switch
  • Type: Manual , PDF
  • Key Aspects: Warranty and Service Information, Operational Mode Explanations, Unpacking and Inspection Guidelines
  • UPD Date: 13.07.2026
  • Source File: 1625162.pdf
  • Pages: 14
  • Description: Complete technical documentation for the Lutron Electronics Maestro MS-OPS6-DDV.
Pages Preview:
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 2
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 3
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 4
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 5
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 6
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 7
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 8
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 9
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Maestro® Dual-Circuit Occupancy Sensing Switch Additional Programming, Installation, and Troubleshooting Help Application Note #489 Revision A July 2013 1 Technical Support — 800.523.9466 MaestroR Dual-Circuit Occupancy Sensing Switch Models MS-OPS6-DDV; MS-PPS6-DDV Overview This document serves as a supplement to the Maestro® Dual-Circuit Occupancy Sensing Switch instruction sheet. Note: For performance specifications, see the Dual-Circuit Occupancy Sensing Switch spec submittal (P/N 369748) at www.lutron.com/occvacsensor Dual-Circuit Occupancy Sensing Switch (shown without faceplate) Circuit 1 Tap Button Circuit 2 Tap Button Top Programming Button Bottom Programming Button Glossary.................................................................Page 2 Explanation of Sensing Switch Features.............Page 3 Sensing Switch Coverage Area...........................Page 6 Sensing Switch Programming.............................Page 7 Additional Programming Options........................Page 9 Restoring Default Settings...................................Page 9 Wiring Diagrams.................................................. Page 10 Ambient Light Detect (ALD) - How it Works........................................................Page 11 Troubleshooting................................................... Page 13 WARNING! Shock Hazard. May result in serious injury or death. For bulb replacement or rewiring, power MUST be disconnected at the main electrical panel
Lutron Electronics Maestro MS-OPS6-DDV Manual  Thumbnail

Lutron Electronics Maestro MS-OPS6-DDV Manual  [PDF] (8 pages)

  • Identifier: id-2331616
  • Brand: Lutron Electronics
  • Device: Lutron Electronics Maestro MS-OPS6-DDV Switch
  • Type: Manual , PDF
  • Key Aspects: Glossary of Technical Terms, Technical Support and Resource Links, Basic Configuration Guidelines
  • UPD Date: 21.08.2026
  • Source File: 1955989.pdf
  • Pages: 8
  • Description: Instruction and reference manual for the Lutron Electronics Maestro MS-OPS6-DDV.
Pages Preview:
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 2
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 3
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 4
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 5
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 6
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 7
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 8
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Important Notes Please read before installing. 1. A ground connection is required for product to function. Connect green-sleeved wire to ground only in retrofit and replacement applications. When neutral connection is available, remove green sleeve and connect to neutral. If neither wire is present, consult a licensed electrician. 2. Device will not function if Black wires (Circuit 1/Line 1) are not wired. 3. This product is rated to control 6 A per circuit. Circuits may NOT be wired in parallel to control loads greater than 6 A. 4. CAUTION: Risk of Electric Shock — More than one disconnect switch may be required to de-energize the equipment before installing the unit, rewiring, or replacing bulbs. 5. When power is applied, the dual- circuit sensing switch can be manually turned on or off after 60 seconds and will automatically control the load after 2 minutes. 6. The dual-circuit sensing switch requires an unobstructed view of the room and line-of-sight to detect motion. 7. Hot objects or moving air currents can affect the performance of the dual-circuit sensing switch and may cause the sensor to turn on unexpectedly or maintain its current state longer than desired. 8. CAUTION: To reduce the risk of overheating and possible damage to other equipment, DO NOT use to control receptacles. 9. Install in accordance with all national and local electrical codes. 10. For indoor use only. Operate between 32 °F and 104 °F (0 °C and 40 °C). 11. DO NOT exceed 20 devices at 120 V~ or 7 devices at 277 V~ on a single branch circuit. 12. Clean with a soft damp cloth only. DO NOT use any chemical cleaners. Wiring NOTE: Leave wallplate off if custom settings are desired. See Custom Settings instructions on reverse side. 1 Device will not function if Black wires (Circuit 1/ Line 1) are not wired. 2 Device will not function if it is not grounded. 2 Connect dual-circuit sensing switch WARNING! Shock Hazard. May result in serious injury or death. Turn power OFF at circuit breaker(s) before installing the unit, rewiring, or replacing bulbs. 1 Turn power OFF A. I I I O O O Single-Line I I I O O O B. Two-Line* ® Dual-Circuit Occupancy Sensing Switch P/N 032555 Rev. A 05/2019 MS-OPS6-DDV UMS-OPS-DDV Occupancy MS-PPS6-DDV UMS-PPS6-DDV Partial-ON only Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 U.S.A. www.lutron.com ® Single-pole only Two circuits, each rated at: Circuit 1 Tap Button Top programming button Bottom programming button Circuit 2 Tap Button Warranty: http://www.lutron.com/TechnicalDocumentLibrary/Sensor_Warranty.pdf Lutron and Maestro are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries. © 2013–2019 Lutron Electronics Co., Inc. Major motion coverage: 30 ft × 30 ft (9 m × 9 m) [900 ft2 (81 m2)] Minor motion coverage: 20 ft × 20 ft (6 m × 6 m) [400 ft2 (36 m2)] * Wiring must comply with NEC code for wiring Multiple Branch Circuits: Where two or more branch circuits supply devices or equipment on the same yoke, a means to simultaneously disconnect the ungrounded conductors supplying those devices shall be provided at the point at which the branch circuits originate. OR 3 Turn Power ON OR I I I O O O A. I I I O O O B. 4 Wait for 60 seconds before manual switching • The sensing switch will not manually control the load for 60 seconds. 5 Wait for an additional 60 seconds for automatic switching • Once power has been restored, the sensing switch will not automatically control the load for the first 2 minutes. Lighting (incandescent, halogen, CFL, LED, ELV, MLV, electronic fluorescent, magnetic fluorescent) 120-277 V~ 50 / 60 Hz 6 A Fan 120 V~ 50 / 60 Hz 4.4 A 1/6 HP Combined lighting and fan load 120 V~ 50 / 60 Hz 4.4 A English Black1 Black1 Black Black White Green-sleeved wire Bare Bare Bare Black- Orange Black- Orange Black- Orange Black- Orange Neutral Neutral Load 1 Load 1 Load 2 Load 2 120–277 V~ 120–277 V~ 120–277 V~ 120–277 V~ 120–277 V~ 120–277 V~ Ground2 Ground2 Single-Line Wiring Single-Line Wiring Two-Line Wiring Two-Line Wiring Neutral 2 Neutral 2 Line 1 Line 1 Load 1 Load 1 Load 2 Load 2 Line 2 Line 2 Neutral 1 Neutral 1 Black1 Black1 Black Black Black- Orange Black- Orange Black- Orange Black- Orange White Bare Ground2 Ground2 B. If no neutral is present, connect green-sleeved wire to ground. A. When neutral is present in outlet box: remove green sleeve, connect white wire to neutral. 60 s 60 s Green-sleeved wire
Lutron Electronics Maestro MS-OPS6-DDV Manual  Thumbnail

Lutron Electronics Maestro MS-OPS6-DDV Manual  [PDF] (6 pages)

  • Identifier: id-2331617
  • Brand: Lutron Electronics
  • Device: Lutron Electronics Maestro MS-OPS6-DDV Security Sensors
  • Type: Manual , PDF
  • Key Aspects: Environmental Factors and Restrictions, Detailed Installation Instructions, Model Variations and Compatibility
  • UPD Date: 06.08.2026
  • Source File: 1955988.pdf
  • Pages: 6
  • Description: Step-by-step user manual for the Lutron Electronics Maestro MS-OPS6-DDV.
Pages Preview:
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 2
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 3
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 4
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 5
  • Lutron Electronics Maestro MS-OPS6-DDV Manual  preview - page 6
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Important Notes Please read before installing. 1. Device will not function if it is not grounded. Both bare and green ground wires are required to connect to ground. If no ground is available, consult an electrician. 2. Device will not function if Black wires (Circuit 1/Line 1) are not wired. 3. This product is rated to control 6 A per circuit. Circuits may NOT be wired in parallel to control loads greater than 6 A. 4. CAUTION: Risk of Electric Shock — More than one disconnect switch may be required to de-energize the equipment before servicing. 5. When power is applied, the dual-circuit sensing switch can be manually turned on or off after the first 30 seconds and will automatically control the load after 2 minutes. 6. The dual-circuit sensing switch requires an unobstructed view of the room and line-of-sight to detect motion. 7. Hot objects or moving air currents can affect the performance of the dual-circuit sensing switch and may cause the sensor to turn on unexpectedly or maintain its current state longer than desired. 8. NOTICE: To reduce the risk of overheating and possible damage to other equipment, DO NOT use to control receptacles. 9. Install in accordance with all national and local electrical codes. 10. For indoor use only. Operate between 32 °F and 104 °F (0 °C and 40 °C). 11. DO NOT exceed 20 devices at 120 V~ or 7 devices at 277 V~ on a single branch circuit. 12. Clean with a soft damp cloth only. DO NOT use any chemical cleaners. Wiring NOTE: Leave wallplate off if custom settings are desired. See Custom Settings instructions on reverse side. a Device will not function if Black wires (Circuit 1/ Line 1) are not wired. b Device will not function if it is not grounded. Blacka Green Bare Black-Orange Neutral Load 1 Load 2 120-277 V~ Black Black-Orange Groundb A. Single-Line Wiring B. Two-Line Wiring Blacka Green Groundb Bare Black-Orange Neutral 2 Line 1 Load 1 Load 2 Line 2 120-277 V~ Neutral 1 Black Black-Orange 120-277 V~ 2 Connect dual-circuit sensing switch WARNING! Shock Hazard. May result in serious injury or death. Turn power OFF at circuit breaker before installing the unit. 1 Turn power OFF A. Single-Line B. Two-Line* ® Dual-Circuit Occupancy Sensing Switch P/N 032436 Rev. B 07/2013 Lighting (all load types) 120-277 V~ 50/60 Hz 6 A Fan 120 V~ 50/60 Hz 4.4 A 1/6 HP Combined lighting and fan load 120 V~ 50/60 Hz 4.4 A MS-OPS6-DDV Occupancy MS-PPS6-DDV Partial-ON only Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 U.S.A. www.lutron.com ® Single-pole only Two circuits, each rated at: Circuit 1 Tap Button Top programming button Bottom programming button Circuit 2 Tap Button Limited Warranty (Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean). Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within five years after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid. This warranty is in lieu of all other express warranties, and the implied warranty of merchantability is limited to FIVE years from purchase. This warranty does not cover the cost of installation, removal or reinstallation, or damage resulting from misuse, abuse, or damage from improper wiring or installation. This warranty does not cover incidental or consequential damages. Lutron’s liability on any claim for damages arising out of or in connection with the manufacture, sale, installation, delivery, or use of the unit shall never exceed the purchase price of the unit. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you. Lutron and Maestro are registered trademarks of Lutron Electronics Co., Inc. © 2013 Lutron Electronics Co., Inc. Major motion coverage: 30 ft × 30 ft (9 m × 9 m) [900 ft2 (81 m2)] Minor motion coverage: 20 ft × 20 ft (6 m × 6 m) [400 ft2 (36 m2)] * Wiring must comply with 2011 NEC code 210.7 for wiring Multiple Branch Circuits: Where two or more branch circuits supply devices or equipment on the same yoke, a means to simultaneously disconnect the ungrounded conductors supplying those devices shall be provided at the point at which the branch circuits originate. OR 3 Turn Power ON OR A. B. 4 Wait for 2 minutes NOTE: The sensing switch will not manually control the load for 30 seconds. Once power has been restored, the sensing switch will not automatically control the load for the first 2 minutes.

Similar Manuals in the Security Sensors, Switch Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Vogel QZ80

Manual: Vogel QZ80 (MK886K, Upd.15-04-2026)

29 892 143 15-04-2026 view all manuals
Eterna PIR360WH

Eterna PIR360WH Guide (Important safety and installation instructions), @8HFL54

2 1224 221 01-04-2026 view all manuals
Optex Smart Line Series

Smart Line Series (Security Sensors ePDF Manual, #6657E1)

20 835 126 23-04-2026 view all manuals
Endress+Hauser NAR300-13 Series

Security Sensors #2C4148

41 237 55 15-08-2026 view all manuals
Bosch AP1-T

AP1-T Installation instructions - ID9P2H

2 654 112 31-03-2026 view all manuals
STEINEL IS 130-2

#9T167L: IS 130-2 Other Manual 

24 4.7 Mb 1441 245 08-06-2026 view all manuals