LUX TX1500B SERIES Manuals

1 pdf manual(s) LUX TX1500B SERIES for free download (Document Types: Installation and operating instructions)

LUX TX1500B SERIES Installation and operating instructions Thumbnail

LUX TX1500B SERIES Installation and operating instructions [PDF] (3 pages)

  • Identifier: id-1143610
  • Brand: LUX
  • Device: LUX TX1500B SERIES Thermostat
  • Type: Installation and operating instructions, PDF
  • Key Aspects: End-of-Life Handling and Disposal, Control Panel and Interface Navigation, Efficiency and Calibration Tips
  • UPD Date: 20.07.2026
  • Source File: 1014769.pdf
  • Pages: 3
  • Description: Installation and maintenance guide for the LUX TX1500B SERIES.
Pages Preview:
  • LUX TX1500B SERIES Installation and operating instructions preview - page 2
  • LUX TX1500B SERIES Installation and operating instructions preview - page 3
Document Preview & Text Transcription (Main Page)
Click to expand and read text
© COPYRIGHT 2006 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED • The TX1500 can be used with most 24 volt gas, oil or electric heating and air conditioning systems, single-stage heat pumps or gas millivolt heating systems. It cannot be used with 120 volt heating systems or multistage heat pumps. Ask your dealer for other LUX thermostats to control those systems. • The TX1500 is programmable. There are four programming periods per day. Each period can be programmed separately. • Easy to use Lux Speed Dial®. • You can use the built-in time/temperature programs, or alter them to suit your schedule. The TX1500 provides separate programming for weekdays, Saturday, and Sunday — for both heating and cooling. You can override the programmed temperatures for as little as one programming period or for an entire vacation. • In cool weather, when the system switch is set to HEAT, the TX1500 will maintain cooler “set back” room temperatures to save energy. It will then change to warmer “comfort” settings — all automatically, at specified times during the day. • In warm weather, when the system switch is set to COOL, the TX1500 will maintain warmer “set back” room temperatures to save energy. It will then change to cooler “comfort” settings - all automatically, at specified times during the day. • A large liquid crystal display shows time, day of the week, and room and set temperatures. It will remind you when the filter should be changed in your blower. • Temperature swing adjustment lets you fine-tune your system for maximum comfort and economy. • 5/2 Minute Selectable Minimum Run/Off Time for Short Cycle/Compressor Protection • Two Energizer ® or DURACELL ® “AA” alkaline batteries (not included) are used to retain your time and temperature program and to light the display. LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA FEATURES I M P O R T A N T ! Thank you for your confidence in our product. To obtain the best results from your investment, please read these instructions and acquaint yourself with your purchase before installing your new thermostat. Then follow the installation procedures, one step at a time. This will save you time and minimize the chance of damaging the thermostat and the systems it controls. These instructions may contain information beyond that required for your particular installation. Please save for future reference. READ INSTALLATION INSTRUCTIONS FIRST TX1500b SERIES SMART TEMP ® ELECTRONIC THERMOSTAT Complete, Easy To Read Programming And Installation Instructions Inside The Active Program Period Liquid Crystal Display Fan Switch System Switch Easy to follow instructions Lux Speed Dial® Thermostat Body The Set Temperature Thermostat Cover Button to Light Display HEAT OFF COOL AUTO ON FAN RESET HOLD NEXT RUN FILTER SET SUNDAY PROGRAM SET SATURDAY PROGRAM SET WEEKDAY PROGRAM SET DAY/TIME DOWN UP 1500 P a t e n t s P e n d i n g MO DAY HEAT PM SIMPLIFIED INSTRUCTIONS • Press UP/DOWN to set time. TO SET PROGRAMS • Rotate Dial to SET WEEKDAY TEMPORARY TEMPERATURE OVERRIDE •Press UP/DOWN to adjust set temperature. •To clear OVERRIDE press UP/DOWN until original set temperature appears or wait for the start tf the next period TO SET TIME & DAY • Rotate Dial to SET DAY/TIME. • Press UP to change t d HEAT OFF COOL AUTO ON FAN RESET HOLD NEXT RUN FILTER SET SUNDAY PROGRAM SET SATURDAY PROGRAM SET WEEKDAY PROGRAM SET DAY/TIME DOWN UP 1500 P a t e n t s P e n d i n g MO DAY HEAT PM SIMPLIFIED INSTRUCTIONS • Press UP/DOWN to set time. TO SET PROGRAMS • Rotate Dial to SET TEMPORARY TEMPERATURE OVERRIDE •Press UP/DOWN to adjust set temperature. •To clear OVERRIDE press UP/DOWN until original set temperature appears or wait for TO SET TIME & DAY • Rotate Dial to SET DAY/TIME. • Press UP to change DOWN UP MO DAY HEAT PM Choose Heat or Cool Set Day & Time Installs Easily Easy as 1–2–3 INSTALLATION AND OPERATING INSTRUCTIONS WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only Energizer® is a registered trademark of Eveready Battery Company, Inc. DURACELL® is a registered trademark of The Gillette Company, Inc. 52017 INSTALLATION Please read all instructions carefully before beginning installation. TOOLS REQUIRED #1 Phillips screwdriver (small) Drill with 3/16-in. (4.8mm) bit THERMOSTAT LOCATION On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, follow the guidelines listed below. 1. Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and in a room that is used often. 2. Do not install it where there are unusual heating conditions, such as: in direct sunlight; near a lamp, radio, television, radiator, register, or fireplace; near hot water pipes in a wall; near a stove on the other side of a wall. 3. Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room; or in a draft from a stairwell, door, or window. 4. Do not locate in a damp area. This can lead to corrosion that will shorten thermostat life. 5. Do not locate where air circulation is poor, such as: in a corner or an alcove; or behind an open door. 6. Do not install the unit until all construction work and painting has been completed. 7. This thermostat does not require leveling. C A U T I O N To avoid electrical shock and to prevent damage to the furnace, air conditioner, and thermostat, disconnect the power supply before beginning work. This can be done at the fuse box, at the circuit breaker, or at the appliance. OFF REMOVING THE OLD THERMOSTAT Switch electricity to the furnace and air conditioner OFF; then proceed with the following steps. 2. Note the letters printed near the terminals. Attach labels (enclosed) to each wire for identification. Remove and label wires one at a time. Make sure the wires do not fall back inside the wall. 3. Loosen all screws on the old thermostat and remove it from the wall. MOUNTING THE TX1500 ON THE WALL 3. Press up on the button on bottom of thermostat and swing the body away from the base and up to remove the body from the base. C A U T I O N Read instructions carefully before removing any wiring from existing thermostat. Wires must be labeled before they are removed. When removing wires from their terminals, ignore the color of the wires since these may not comply with the standard. Y W 1. Remove cover from old thermostat. Most are snap-on types and simply pull off. Some have locking screws on the side. These must be loosened. C A U T I O N Be careful not to drop the body or disturb electronic parts. Leave the cover closed while the body is being removed from the base. Y W R 2. Fill wall opening with non-combustible insulation to prevent drafts from affecting the thermostat. Y W 1. Strip insulation 3/8 in. (9.5mm) from wire ends and clean off any corrosion. C A U T I O N • Your thermostat is a precision instrument. Please handle it with care. • Turn off electricity to the appliance before installing or servicing thermostat or any part of the system. Do not turn electricity back on until work is completed. • Do not short (jumper) across electric terminals at control on furnace or air conditioner to test the system. This will damage the thermostat and void your warranty. • All wiring must conform to local codes and ordinances. • This thermostat is designed for use with 24 volt and millivolt systems. The thermostat should be limited to a maximum of 1.0 amps; higher amperage may cause damage to the thermostat. If you are in doubt, call your utility company. Downloaded from www.Manualslib.com manuals search engine

Similar Manuals in the Thermostat Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Energate Foundation

PDF User Manual (@RIX12J), Energate Foundation Thermostat (13-07-2026)

79 1297 260 13-07-2026 view all manuals
Hitachi PC-ARF

PC-ARF (Temperature Controller ePDF User Manual, #A5VPLX)

41 465 107 25-06-2026 view all manuals
Lux Products TX250

Lux Products TX250 Guide (Installation and operating instructions), @1O52TN

3 893 224 22-07-2026 view all manuals
Inngenso IT WiFi

PDF User Manual (@DLAQ6T), Inngenso IT WiFi Thermostat (19-03-2026)

44 878 202 19-03-2026 view all manuals
Hunter 44668

Thermostat #E35YJF

8 1492 359 13-08-2026 view all manuals
Thermokon JOY Fancoil EC 3AO RS485 Modbus

JOY Fancoil EC 3AO RS485 Modbus Datasheet - 45QBE4

8 828 125 09-03-2026 view all manuals