LUX TX500 Series Manuals

1 pdf manual(s) LUX TX500 Series for free download (Document Types: Installation and operating instructions)

LUX TX500 Series Installation and operating instructions Thumbnail

LUX TX500 Series Installation and operating instructions [PDF] (3 pages)

  • Identifier: id-1006815
  • Brand: LUX
  • Device: LUX TX500 Series Thermostat
  • Type: Installation and operating instructions, PDF
  • Key Aspects: Standard Operating Procedures, Pre-Deployment Preparation Steps, System Connectivity and Wiring Basics
  • UPD Date: 11.06.2026
  • Source File: 1151670.pdf
  • Pages: 3
  • Description: Product instruction manual for the LUX TX500 Series.
Pages Preview:
  • LUX TX500 Series Installation and operating instructions preview - page 2
  • LUX TX500 Series Installation and operating instructions preview - page 3
Document Preview & Text Transcription (Main Page)
Click to expand and read text
LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA • In cool weather, when the system switch is set to HEAT, the TX500 will maintain cooler “set back” room temperatures to save energy. It will then change to warmer “comfort” settings - all automatically, at specified times during the day. • In warm weather, when the system switch is set to COOL, the TX500 will maintain warmer “set back” room temperatures to save energy. It will then change to cooler “comfort” settings - all automatically, at specified times during the day. • A large liquid crystal display shows time, day of the week, and room and set temperatures. • A 4-minute minimum off time in COOL prevents your air conditioning system from being damaged. • Two “AA” batteries (not included) are used to retain your time and temperature programs. Thank you for your confidence in our product. To obtain the best results from your investment, please read this manual and acquaint yourself with your purchase before installing your new thermostat. Then follow the installation procedures, one step at a time. This will save you time and minimize the chance of dam- aging the thermostat and the systems it controls. These instructions may contain information beyond that required for your particular installation. Please save for future reference. I M P O R T A N T ! READ THE INSTALLATION INSTRUCTIONS FIRST. FEATURES • The TX500 can be used with most 24 volt gas, oil or electric heating and air conditioning systems or gas millivolt heating systems. It cannot be used with 120 volt heating systems or heat pumps. Ask your dealer for other LUX thermostats to control those systems. • The TX500 is programmable. There are four programming periods per day. Each period can be programmed separately. • You can use the built-in time/ temperature programs, or alter them to suit your schedule. The TX500 provides separate programming for weekdays and weekends — for both heating and cooling. You can override the programmed temperatures for as little as one program- ming period or for an entire vacation. HEAT OFF COOL AUTO ON FAN RESET HOLD NEXT RUN SET SUNDAY PROGRAM SET WEEKDAY PROGRAM SET DAY/TIME 500 P a t e n t s P e n d i n g SIMPLIFIED INSTRUCTIONS TO SET PROGRAMS • Rotate Dial to SET WEEKDAY, SATURDAY or SUNDAY PROGRAM. • Press UP/DOWN to adjust start time. • Press NEXT. • Press UP/DOWN to adjust temperature. • Press NEXT. • Repeat as needed or rotate dial to RUN to stop Programming. TEMPORARY TEMPERATURE OVERRIDE •Press UP/DOWN to adjust set temperature. •To clear OVERRIDE press UP/DOWN until original set temperature appears or wait for the start tf the next period. TEMPERATURE HOLD • Press HOLD. Adjust temperature as desired with UP/DOWN. •To clear, press HOLD again. Need Help? Call 1-800-421-1130 TO SET TIME & DAY • Rotate Dial to set DAY/TIME. • Press UP to change current day. • Press NEXT. • Press UP/DOWN to set time. Rotate the dial to the RUN position to close the door. DOWN UP MO MORN DAY EVE NIGHT H E A T PM The Active Program Period Liquid Crystal Display Fan Switch System Switch Thermostat Cover Programming Dial Thermostat Body/Sub-base The Set Temperature FIGURE A C A U T I O N • Your thermostat is a precision instrument. Please handle it with care. • Turn off electricity to the appliance before installing or servicing thermostat or any part of the sys- tem. Do not turn electricity back on until work is completed. • Do not short (jumper) across electric terminals at control on furnace or air conditioner to test the system. This will damage the thermostat and void your warranty. • All wiring must conform to local codes and ordinances. • This thermostat is designed for use with 24 volt and millivolt systems. The thermostat should be limited to a maximum of 1.0 amps; higher amperage may cause damage to the thermostat. If you are in doubt, call your utility company. 43228 Rev B TX500 SERIES SMART TEMP ELECTRONIC THERMOSTAT Complete, Easy To Read Programming And Installation Instructions Inside A l’intérieur, instructions complétes pour l’installation et la programmation faciles à comprende HEAT OFF COOL AUTO ON FAN RESET HOLD NEXT RUN SET SUNDAY PROGRAM SET WEEKDAY PROGRAM SET DAY/TIME 500 P a t e n t s P e n d i n g SIMPLIFIED INSTRUCTIONS TO SET PROGRAMS • Rotate Dial to SET TEMPORARY TEMPERATURE OVERRIDE P UP/DOWN TO SET TIME & DAY • Rotate Dial to set DAY/TIME. DOWN UP MO MORN DAY EVE NIGHT H E A T PM HEAT OFF COOL AUTO ON FAN RESET HOLD NEXT RUN SET SUNDAY PROGRAM SET WEEKDAY PROGRAM SET DAY/TIME 500 P a t e n t s P e n d i n g SIMPLIFIED INSTRUCTIONS TO SET PROGRAMS • Rotate Dial to SET WEEKDAY TEMPORARY TEMPERATURE OVERRIDE •Press UP/DOWN to TO SET TIME & DAY • Rotate Dial to set DAY/TIME. P UP t h DOWN UP MO MORN DAY EVE NIGHT H E A T PM DOWN UP MO MORN DAY EVE NIGHT H E A T PM Choose Heat or Cool Escoja Calentar O Enfríar Set Day & Time Programe el día y la hora Installs Easily Fácil de Instalar Easy as 1–2–3 INSTALLATION AND OPERATING INSTRUCTIONS Please read all instructions carefully before beginning installation. TOOLS REQUIRED #1 Phillips screwdriver (small) Drill with 3⁄16-in. (4.8mm) bit THERMOSTAT LOCATION On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, follow the guidelines listed below. 1. Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and in a room that is used often. 2. Do not install it where there are unusual heating conditions, such as: in direct sunlight; near a lamp, radio, television, radiator, register, or fireplace; near hot water pipes in a wall; near a stove on the other side of a wall. 3. Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room; or in a draft from a stairwell, door, or window. 4. Do not locate in a damp area. This can lead to corrosion that will shorten thermostat life. 5. Do not locate where air circulation is poor, such as: in a corner or an alcove; or behind an open door. 6. Do not install the unit until all construction work and painting has been completed. 7. This thermostat does not require leveling. REMOVING THE OLD THERMOSTAT Switch electricity to the furnace and air conditioner OFF; then proceed with the following steps. 2. Note the letters printed near the terminals. Attach labels (enclosed) to each wire for identifi- cation. Remove and label wires one at a time. Make sure the wires do not fall back inside the wall. 3. Loosen all screws on the old thermostat and remove it from the wall. MOUNTING THETX500 ON THE WALL 3. Press up on the button on bottom of thermostat and swing the body away from the base and up to remove the body from the base. C A U T I O N Read instructions carefully before removing any wiring from existing thermostat. Wires must be labeled before they are removed. When removing wires from their ter- minals, ignore the color of the wires since these may not comply with the standard. C A U T I O N Be careful not to drop the body or disturb electronic parts. Leave the cover closed while the body is being removed from the base. Y W 1. Remove cover from old thermostat. Most are snap-on types and simply pull off. Some have locking screws on the side. These must be loos- ened. Y W R 2. Fill wall opening with non-combustible insula- tion to prevent drafts from affecting the ther- mostat. Y W 1. Strip insulation 3⁄8 in. (9.5mm) from wire ends and clean off any corrosion. INSTALLATION C A U T I O N To avoid electrical shock and to prevent damage to the furnace, air conditioner, and thermostat, disconnect the power supply before beginning work. This can be done at the fuse box, at the circuit breaker, or at the appliance. OFF

Similar Manuals in the Thermostat Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Carrier TB-NAC

User Guide: Carrier TB-NAC (T51T17, Upd.31-08-2026)

6 0.42 Mb 642 116 31-08-2026 view all manuals
Tekmar Invita

Tekmar Thermostat Operation & user’s manual (File: PDF, 26-03-2026)

8 898 144 26-03-2026 view all manuals
CALEFFI 738

PDF User Manual (@88ZNJ4), CALEFFI 738 Thermostat (14-04-2026)

84 328 82 14-04-2026 view all manuals
Nibe RMU S40

Nibe Control Unit Installer manual (File: PDF, 21-05-2026)

80 168 29 21-05-2026 view all manuals
OJ Electronics OCC4

Thermostat #1AC376

4 574 144 20-06-2026 view all manuals
Bard CMA-43

CMA-43 (Thermostat ePDF Guide, #VFE545)

3 247 40 06-04-2026 view all manuals