M-system 47 Series Manuals
7 pdf manual(s) M-system 47 Series for free download (Document Types: Manual , Operating manual)
M-system 47 Series Manual [PDF] (8 pages)
- Identifier: id-1978200
- Brand: M-system
- Device: 47 Series Measuring Instruments
- Type: PDF
- Key Aspects: Storage and Care Recommendations, Warranty and Service Information, System Limitations and Considerations
- UPD Date: 01.07.2026
- Source File: 2309660.pdf
- Pages: 8
- Description: Quick reference guide for the M-system 47 Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
MODEL: 47LT 47LT SPECIFICATIONS ES-9512 Rev.11 Page 1/8 https://www.m-system.co.jp/ Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features • 4-digit thermocouple input digital panel meter • 1/8 DIN size • Moving average function to suppress the display flickering • Max. and Min. value display • IP66 front panel • Separable terminal block • Rear terminal cover for safety strapped to the meter Alarm/ Init/ Max/Min Shift Up Ini Alm D/P Adj Fnc Min Max HH H P L LL 48 (1.89) mm (inch) 96 (3.78) 98.5 (3.88) MODEL: 47LT-1[1][2][3]-[4][5] ORDERING INFORMATION • Code number: 47LT-1[1][2][3]-[4][5] Specify a code from below for each of [1] through [5]. (e.g. 47LT-101G-M2/Q) • Specify the specification for option code /Q (e.g. /C01/S01/SET) INPUT – Field-selectable 1: (PR), K (CA), E (CRC), J (IC), T (CC), B (RH), R, S, N [1] DC OUTPUT 0: Without Current A: 4 – 20 mA DC (Load resistance 550 Ω max.) D: 0 – 20 mA DC (Load resistance 550 Ω max.) Voltage 4: 0 – 10 V DC (Load resistance 10 kΩ min.) 5: 0 – 5 V DC (Load resistance 5000 Ω min.) 6: 1 – 5 V DC (Load resistance 5000 Ω min.) 4W: -10 – +10 V DC (Load resistance 10 kΩ min.) [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White [4] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) [5] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) Moving parts and indicators are not coated. /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL /S01: Stainless steel EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-9512) GENERAL SPECIFICATIONS Construction: Panel flush mounting Degree of protection: IP66; applicable to the front of the panel meter mounted according to the specified panel cutout Connection: M3 separable screw terminal (torque 0.6 N·m) Screw terminal: Nickel-plated steel (standard) or stainless steel Housing material: Flame-resistant resin (gray) Isolation: Input to DC output to HH output or H output to L output or LL output to power Burnout: Upscale standard; downscale optional by programming Linearization: Standard Cold junction compensation: CJC sensor attached to the input terminals Setting: (Front button)
M-system 47 Series Manual [PDF] (9 pages)
- Identifier: id-1978201
- Brand: M-system
- Device: 47 Series Measuring Instruments
- Type: PDF
- Key Aspects: Component Overview and Descriptions, Basic Configuration Guidelines, Control Panel and Interface Navigation
- UPD Date: 01.04.2026
- Source File: 2309659.pdf
- Pages: 9
- Description: Operation and maintenance manual for the M-system 47 Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
47LT P. 1 / 9 ES-9512 Rev.1 Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) MODEL 47LT Functions & Features • 4-digit thermocouple input digital panel meter • 1/8 DIN size • Moving average function to suppress the dis- play flickering • Max. and Min. value display • IP66 front panel • Separable terminal block • Rear terminal cover for safety strapped to the meter Specifications are subject to change without notice. MODEL & SUFFIX CODE SELECTION ORDERING INFORMATION Specify code number. (e.g. 47LT-101G-M2) GENERAL SPECIFICATIONS Construction: Panel flush mounting Degree of protection: IP66; applicable to the front panel for the meter mounted according to the specified panel cutout Connection: M3 screw terminals (nickel plated steel; torque 0.6 N·m) Material: Flame resistant resin (black) Scaling: Programming via the front buttons Averaging: None or moving average Security: Prohibiting certain operations; protecting settings DISPLAY Display: 16 mm (.63) high, 4 digits (-1999 to 9999), LED Scaling: No scaling (input temperature indication) Decimal point position: 10 –1 or none (fixed depending upon the input type) Minimum display/setting scale: 1°C or 1°F (0.1°C for K and J, narrow span) Read rate: Max. 40/second (25 milliseconds) Over-range indication: ‘S.ERR’ flashing when the input signal is out of the usable range. Burnout indication: ‘B.ERR’ flashing Alarm status indication* LL indicator: Turns on when the LL alarm is tripped. L indicator: Turns on when the L alarm is tripped. H indicator: Turns on when the H alarm is tripped. HH indicator: Turns on when the HH alarm is tripped. P indicator: Turns on when none of the other alarms is tripped. Zero indication: Higher-digit zeros are suppressed. Engineering unit indication: Sticker label attached *Only ‘P’ turns on with no-alarm-output type. ‘LL’ or ‘HH’ does not turn on with dual-alarm-output type. All setpoints can be independently set either for Hi or Lo alarm trip. Alarm/ Init/ Max/Min Shift Up Ini Alm D/P Adj Fnc Min Max HH H P L LL 48 (1.89) mm (inch) 96 (3.78) 98.5 (3.88) 47LT–1❑❑❑–❑ MODEL INPUT THERMOCOUPLE (field-configurable) 1 : (PR), K (CA), E (CRC), J (IC), T (CC), B (RH), R, S, N DC OUTPUT 0 : None Current A : 4 – 20mA DC D : 0 – 20mA DC ALARM OUTPUT 0 : None 1 : N.O. relay contact, 4 points 2 : SPDT relay contact, 2 points DISPLAY COLOR R : Red YR : Orange G : Green BG : Bluegreen B : Blue W : White POWER INPUT AC Power DC Power M2 : 100 – 240V AC R : 24V DC Voltage 4 : 0 – 10V DC 5 : 0 – 5V DC 6 : 1 – 5V DC 4W : -10 – +10V DC
M-system 47 Series Manual [PDF] (12 pages)
- Identifier: id-2367635
- Brand: M-system
- Device: 47 Series Measuring Instruments
- Type: PDF
- Key Aspects: System Architecture and Design Overview, Package Contents and Accessories List, FAQ Section for Common Queries
- UPD Date: 08.03.2026
- Source File: 1919969.pdf
- Pages: 12
- Description: Product documentation for the M-system 47 Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
MODEL: 47DR 47DR SPECIFICATIONS ES-9509 Rev.12 Page 1/12 http://www.m-system.co.jp/ Digital Panel Meters 47 Series RTD INPUT DIGITAL PANEL METER (5 digit, LCD display type) Functions & Features • 5 digit RTD input digital panel meter • 1/8 DIN size • Display color can be changed at alarm • Bargraph indicator shows approximate measuring status • 12 V or 24 V excitation supply • External event trigger input • RS-485 / Modbus RTU output • Infrared interface • BCD output • Loop test output (DC output option) • IP66 front panel • Separable terminal block • Safety terminal cover tethered to the device with a strap Alarm/ Init/ Max/Min Shift Up 48 (1.89) mm (inch) 96 (3.78) 98.5 (3.88) Max Min NG Ini Alm TG Hld °F °C HH H P L LL MODEL: 47DR-1[1][2][3]-[4][5] ORDERING INFORMATION • Code number: 47DR-1[1][2][3]-[4][5] Specify a code from below for each [1] through [5]. (e.g. 47DR-1111-M2/Q) • Specify the specification for option code /Q (e.g. /C01/S01/SET) INPUT – Field-selectable RTD 1: JPt 100 (JIS ’89) Pt 100 (JIS ’89) Pt 100 (JIS ’97, IEC) Pt 50Ω (JIS ’81) Pt 1000 [1] DC OUTPUT 0: Without 1: With [2] EXCITATION SUPPLY 1: +12 V sensor excitation 2: +24 V two-wire transmitter excitation [3] I/O OPTIONS 0: None 1: Alarm output: N.O. relay, 4 points 2: Alarm output: SPDT relay, 2 points 3: Alarm output: N.O. photo MOSFET relay, 4 points 4: Network interface: RS-485 / Modbus RTU 5: BCD output 6: Event trigger input 7: Alarm output: N.O. relay, 4 points + Network interface: RS-485 / Modbus RTU 8: Alarm output: SPDT relay, 2 points + Network interface: RS-485 / Modbus RTU 9: Alarm output: N.O. photo MOSFET relay, 4 points + BCD output A: Event trigger input + BCD output [4] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) [5] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) Moving parts and indicators are not coated. /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL /S01: Stainless steel EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-9509) RELATED PRODUCTS • Connector terminal block (model: CNT) • Special cable (model: HDR40) • Infrared Communication Adaptor (model: COP-IRU) • PC configurator software (model: 47DCFG) Downloadable at M-System’s web site.
M-system 47 Series Operating manual [PDF] (136 pages)
- Identifier: id-1605035
- Brand: M-system
- Device: 47 Series Measuring Instruments
- Type: PDF
- Key Aspects: Technical Data and Parameters, Periodic Inspection Checklists, Recommended Spare Parts List
- UPD Date: 05.08.2026
- Source File: 1625290.pdf
- Pages: 136
- Description: Operating and setup manual for the M-system 47 Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 47LV OPERATING MANUAL EM-9502-B Rev.7 Digital Panel Meters 47 Series DC INPUT DIGITAL PANEL METER (4 1/2 digit, LED display type) Model: 47LV OPERATING MANUAL http://www.m-system.co.jp/ 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 E-mail: [email protected]
M-system 47 Series Operating manual [PDF] (254 pages)
- Identifier: id-2367636
- Brand: M-system
- Device: 47 Series Measuring Instruments
- Type: PDF
- Key Aspects: Component Overview and Descriptions, Documentation and Revision History, System Limitations and Considerations
- UPD Date: 10.03.2026
- Source File: 1919968.pdf
- Pages: 254
- Description: Official user manual for the M-system 47 Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 47DV OPERATING MANUAL EM-9501-B Rev.9 Digital Panel Meters 47 Series DC INPUT DIGITAL PANEL METER (5 1/2 digit, LCD display type) Model: 47DV OPERATING MANUAL http://www.m-system.co.jp/ 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 E-mail: [email protected]
M-system 47 Series Operating manual [PDF] (131 pages)
- Identifier: id-1718148
- Brand: M-system
- Device: 47 Series Measuring Instruments
- Type: PDF
- Key Aspects: Environmental Factors and Restrictions, Warranty and Service Information, Regulatory Compliance and Standards
- UPD Date: 11.04.2026
- Source File: 1719061.pdf
- Pages: 131
- Description: Owner’s guide for the M-system 47 Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 47LPA OPERATING MANUAL EM-9515-B Rev.8 Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4 1/2 digit, LED display type) Model: 47LPA OPERATING MANUAL http://www.m-system.co.jp/ 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 E-mail: [email protected]
M-system 47 Series Operating manual [PDF] (137 pages)
- Identifier: id-1718149
- Brand: M-system
- Device: 47 Series Measuring Instruments
- Type: PDF
- Key Aspects: Regulatory Compliance and Standards, User Training Recommendations, FAQ Section for Common Queries
- UPD Date: 27.06.2026
- Source File: 1719060.pdf
- Pages: 137
- Description: Operation instructions for the M-system 47 Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 47LPQ OPERATING MANUAL EM-9516-B Rev.10 Digital Panel Meters 47 Series PULSE INPUT TOTALIZER (6-digit, LED display type) Model: 47LPQ OPERATING MANUAL http://www.m-system.co.jp/ 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 E-mail: [email protected]