A. Foreword
1
A. Safety Precautions
2
1. Warning
2
2. Attention
3
3. Safety
3
B. About your heat pump
4
1. Transportation
4
2. Accessories
4
3. Features
4
4. Operating condition and range
4
5. Introduction of different modes
5
6. Technical parameters
6
7. Dimensions
7
C. Installation
8
1. Installation requirements
8
3. Wiring requirements
9
4. Electric wiring Diagram
10
5. References for protection devices and cable specification
10
D. Operation guidance
15
1. Display Functions
15
2.Operation Instruction
16
E. Testing
18
F. Commissioning
19
G. Maintenance
20
H. Trouble shooting for common faults
21
I. Appendix
24
Water Testing Pump Output
26
External input
26
J. WiFi operation
27
L. Product Purchase Warranty Registration
9
1
A. Foreword
Thank you for choosing the Madimack high efficiency inverter pool heat pump.
All our heat pumps are built and designed to the highest standard and are protected by our extended
warranty service for peace of mind.
Warranty registration is required to be submitted online in conjunction with the commissioning page and
warranty registration page in the Appendix section at the back of the booklet
www.madimack.com.au/warranty-registration
Please read and fully understand all information provided before attempting to install the pool heat
pump.
For technical questions and further information please contact
[email protected]
We hope you enjoy using our heat pumps.
Thank you!
2
A. Safety Precautions
We have provided important safety messages in this manual for the installation, maintenance and repair
of your heater.
Please read thoroughly and obey all safety messages.
Environmentally friendly R32 Refrigerant is used in this heat pump
1. Warning
This WARNING sign denotes a hazard. It calls attention to a procedure,
practice, or the like, which, if not correctly performed or adhered to, could
result in personal injury or injury to a third party. These signs are rare, but
are extremely important.
a.
Keep the heat pump away from fire source.
b.
Unit must be placed in a well-ventilated area; indoor or enclosed areas are not
allowed.
c.
Repair and disposal must be carried out by trained service personnel
d. Vacuum the system completely before welding.
Welding should only be carried out by professional trained personnel.