Maxwell Digital Multimeters 25521A Manuals

1 pdf manual(s) Maxwell Digital Multimeters 25521A for free download (Document Types: Operation & user’s manual)

Document Preview & Text Transcription

CLAMP ADAPTER - FLEXIBLE STEM STROMZANGENADAPTER – FLEXIBLE SCHLEIFE LAKATFOGÓ ADAPTER – FLEXIBILIS HUROK ADAPTÉR KE KLEŠŤOVÉ MULTIMETRY - FLEXIBILNÍ SMYČKA ADAPTÉR KU KLIEŠŤOVÉMU MULTIMETRU - FLEXIBILNÁ SLUČKA ADAPTER CĘGOWY – ELASTYCZNY ZACZEP ADAPTOR CLAMPMETRU – CU BUCLĂ FLEXIBILĂ 25521A i User Manual Gebrauchsanweisung Használati utasítás Návod k použití Návod na použitie Instrukcja obsługi Manual de utilizare CZ EN DE HU SK PL RO all-gu ides.c om Operation: Place the black banana plug of the Clamp adapter into the “COM” socket of the multimeter and the red into the “V” socket. Switch the multimeter to the smallest AC mV meter position. Turn on the padlock adapter by moving the power switch to the ON position. Roll the flexible measuring spindle locking nut to UNLOCK and unplug it from the socket. Place it around the measuring wire and put it back into the socket and lock it in the LOCK direction. Set the conversion rate on the adapter: 1mV/A, 10mv/A, 100mV/A. Change the readable mV value of the instrument based on the already set measurement limit. The measurement can be measured on a conductor that runs current, at a time even more than one can be measured, in which case the total value of the conductors is displayed on the instrument, but it is recommended to measure them one by one for exact measurement. The measure will be ineffective if, for example. a phase and a zero (AC) conductor are placed side by side within the flexible stem. The measurement is the most accurate in the middle of the shape of the flexible stem. Warning: • Before starting the measurement, handle the wires under voltage with great caution, avoiding electrical shocks • Do not use in wet, humid environments • Do not expose the radiant heat to the instrument (sunlight, radiators, etc.) • Do not use the instrument if it or the cables are damaged • Do not use the instrument if the voltage of the circuit under test exceeds the CAT rating (CAT III -1000V, CAT IV - 600V) Battery replacement: Open the battery case screw and remove it with the batteries. Insert the new batteries correctly into the battery compartment. Replace the holder and secure with the screw. Safety instructions: The device complies with CAT III -1000V and CAT IV - 600V classification categories, as well as EN 61010-1, EN 61010-2-032 and standards. The level of pollution is the same as the indoor use IEC 664. If the device is not used as intended, it may be damaged. EN USER MANUAL Features: Measurement interval: 0.1 - 3000 A (AC) Current clamp voltage output: 1 mV - 3000 mV Measurement switching unit: 1 mV / 1 A, 10mv / 1 A, 100 mV / A Precision (50-60 Hz, 25 °C): 0 A - 3000 A ±(2% + 0.1 A) Status indication (ON-OFF ): yes Cable length: 170 cm Connection: standard insulated banana plug Operating temperature: -5 °C to 45 °C ( 20 - 85% relative humidity) Storage temperature: -20 °C to 70 °C ( 20 -80% relative humidity) Flexible clamp maximum capacity: 100 mm Battery Type: 2x 1.5 V AAA Size - clamping Stem : 200 x 130 x 24 mm - controller: 97 x 35 x 25 mm Weight: 258 g (without batteries) Material: plastic