Maxwell Digital Multimeters 25624 Manuals

1 pdf manual(s) Maxwell Digital Multimeters 25624 for free download (Document Types: Operation & user’s manual)

Document Preview & Text Transcription

User Manual Anwendungsinformation Használati utasítás Manual de utilizare Užívateľská príručka Product code / Produkt code / Termékkód / Cod produs / Kód produkta: 25624 all-guides. com EN User Manual Safety • Do not exceed the maximum allowed inward ranges. • Do not measure voltage in resistance measuring function. • Set the function switch to „OFF” if you do not use the device. • Set the function switch to the correct position before measuring with the device. • When measuring voltage (V) do not set the device to current / resistance mode. • If you want to switch the measuring range, use the function switch but always remove the wires first. • Do not exceed the maximum allowed inward thresholds. Warning Improper use of the device may lead to injury, damage and even death. Read the manual carefully before using the device. Always remove the wires from the device before replacing the battery. Verify the intactness of the wires and the device before usage. Replace all faulty parts or have them repaired before using the device. Be very careful when measuring above 25VAC RMS or 35VDC as these voltages may cause serious injury. When storing the device for a longer time period remove the battery. Always discharge capacitors and make sure the circuit is not under power when measuring diode, resistance or continuity. • Voltage measuring may be difficult and misleading due to uncertainty of the connection. Other methods should be used to determine whether the connection is right. • Safety functions of the device are only effective if the device is used as prescribed by the manufacturer. Function Max. inward value DC+AC Watt 240kW A AC,A DC 1000A V DC, V AC 600V DC/AC Function Max. inward value Resistance, diode, continuity, frequency, duty cycle measurement 250V DC/AC Setup Hz% A A A AC K W DC + MC-25 624 1 8 9 10 11 12 2 3 4 5 6 7 1. Clamps 2. Trigger 3. Data hold and backlight button 4. Function selection switch 5. Hz / % function 6. LCD display 7. COM connector 8. Rotating function switch 9. ZERO button 10. Measuring range button 11. V, Ω, Cap, W, Hz connector 12. Battery holder Specifications Function Range Accuracy(% read value) DC current 1000 A DC ± (1.8% + 5 digit) AC current 1000 A AC ± (2.0% + 5 digit) User Manual EN Function Range Accuracy(% read value) DC voltage 400 mVDC ± (1.5% + 3 digit) 4 VDC 40 VDC 400 VDC 600 VDC ± (2.0% + 3 digit) AC voltage 400 mVAC ± (0.8% + 20 digit) 4 VAC ± (1.8% + 5 digit) 40 VAC 400 VAC 600 VAC ± (2.5% + 5 digit) Resistance 400 Ω ± (1.0% + 4 digit) 4 kΩ ± (1.5% + 2 digit) 40 kΩ 400 kΩ 4 MΩ ± (2.5% + 3 digit) 40 MΩ ± (3.5% + 5 digit) Function Range Accuracy (% read value) Frequency 5 Hz ± (1.5% + 5 digit) 50 Hz ± (1.2% + 2 digit) Sensitivity: 10 V RMS min. 500 Hz 5 kHz 50 kHz 100 kHz Duty cycle 0.5 - 99.0% ± (1.2% + 2 digit) Width:100μs-100ms, Frequency: 5Hz-100kHz AC Watt 0-250V, 0-400A 50/60Hz TRMS 40 kW ± (2.5% + 5 digit) AC Watt 0-600V, 0-400A 50/60Hz TRMS 240 kW ± (2.5% + 5 digit) Function Range Accuracy (% read value) DC Watt 0-250V, 0-400A 40 kW ± (2.0% + 5 digit) DC Watt 0-250V, 0-400A 240 kW ± (2.0% + 5 digit) Clamp size appr. 1.2” (30mm) when open Diode test current 0.3mA; open circuit voltage 1.5V DC Continuity threshold <100Ω; test current < 1mA Low battery indicator " BAT " is displayed Overload " OL " is displayed Measuring time 2 seconds Input 7.8MΩ (VDC and ADC) Display 4 digit LCD AC current 50/60Hz true RMS (AAC) AC voltage bandwidth 50/60Hz true RMS (VAC) Operating temperature 14-122°F (-10-50°C) Storage temperature -14-140°F (-30-60°C) Relative humidity 90% (0°C-30°C); 75% (30°C-40°C); 45% (40°C-50°C) Altitude operating: 3.000m; storage: 10.000m High voltage Category III. 600V Battery 9V Automatic turn off appr. 35 min Dimensions / weight 229 x 80 x 49mm / 303g