Memmert ICP Manuals

4 pdf manual(s) Memmert ICP for free download (Document Types: Quick start manual)

Document Preview & Text Transcription

www.memmert.com QUICK START GUIDE КРАТКОЕ РУКОВОДСТВО عيرسلا ءدبلا ليلد راهنمای شروع سریع PANDUAN MEMULAI CEPAT 快速入门指南 EN RU AR FA ID ZH ICP | ICPeco ICH | ICHeco ICH L | ICHeco L ICH C D48985 - 01/2021 2 SAFETY INSTRUCTIONS QUICK START GUIDE - ENGLISH This guide provides a brief overview of the operation of Memmert appliances and the safety regulations that you must be observed. These instructions contain only basic information that is relevant to your appliance for initial information. For detailed descriptions of individual functions, please refer to the operating manual of your appliance. Information on the type of appliance, size and power data can be obtained directly from the type plate on the appliance. Detailed instructions for your device can be found in PDF format on the supplied USB stick (only devices with TwinDISPLAY) or on the Internet at: www.memmert.com/user-manuals Always read the complete operating instructions before working with the device! Danger of suffocation. CO2 can have a suffocating effect in high con- centrations. In normal operation, the appliance emits small amounts of CO2 to its surroundings. You should therefore ensure that the room in which it is installed is properly ventilated. Always close the stop valve or pressure reducer on the gas bottle if the appliance is currently not in operation. WARNING After removing covers, live parts may be exposed. You may receive an electric shock if you touch these parts. Disconnect the mains plug be- fore removing any covers. Only electrical technicians may work on the electrical equipment of the appliances. WARNING Scan for detailed informations! Gas bottles may burst or explode at high temperatures. Keep the gas bottles away from open fl ames. Store gas bottles below 50 °C and ensure that the location is always well ventilated. Prevent water from penetrating as well as backfl ow into the gas bottles. It is essential that you read the safety notes and instructions of the gas supplier. WARNING If the door is open while the appliance is in operation, the appliance may overheat and pose a fire hazard. Do not leave the door open during operation. WARNING High concentrations of CO2 can cause cold burns or frostbite. Avoid contact with CO2 gas to the eyes and skin. CAUTION WARNING When loading the appliance with an unsuitable load, poisonous or ex- plosive vapours or gases may be produced. This could cause the appli- ance to explode, and persons could be severely injured or poisoned. The appliance may only be loaded with materials/test objects which do not form any toxic or explosive vapours when heated up. In case of appliances of a certain size, you can get accidentally locked in, which is life-threatening. Do not climb into the appliance. WARNING Risk of poisoning due to slow refrigerant leakage. If the filling quantity of CO2 is greater than the maximum filling quantity (filling quantity 375 g), a CO2 warning device and ventilation in machine rooms must be pro- vided. ICH eco/ICH L eco refrigeration systems may only be installed in rooms of at least 4 m³. WARNING UV light is a danger to your eyes. Your eyes could be injured by UV light if you do not wear protection. Always wear UV safety goggles when opening the door of the ICH L / ICH L eco. This is indicated by the warning signs on the door. WARNING Additional safety instructions for the models ICH L and ICH L eco Additional safety instructions for the models ICH C Additional safety instructions for the models ICx eco 3 GENERAL INSTRUCTIONS FOR USE Requirements of the operating personnel The appliance may only be operated and maintained by persons who are of legal age and have been instructed accordingly. Personnel who are to be trained, instructed or who are undergoing general training may only work with the appliance under the con- tinuous supervision of an experienced person. Repairs may only be performed by qua- lified electricians. The regulations in the separate service manual must be observed. Changes and alterations No unauthorised changes or alterations may be made to the appliance. No parts may be added or inserted which have not been approved by the manufacturer. Unauthori- sed modifications or changes result in the CE declaration of conformity losing its vali- dity and the appliance must no longer be operated. The manufacturer is not liable for any damage, danger or injuries that result from unauthorised changes or alterations, or from non-observance of the regulations in this manual. Behaviour in case of malfunctions and irregularities The appliance may only be used in a flawless condition. If you as the operator notice irregularities,malfunctions or damage, immediately take the appliance out of service and inform your superior. Switching off the appliance in an emergency Push the On/Off switch on the control panel and disconnect power plug. This disconnects the ap- pliance from the power supply at all poles. Applied directives and standards X Directive 2014/30/EU amended Directive of the council for harmonisation of the laws of the member states on elec- tromagnetic compatibility. Standards complied with: DIN EN 61326-1:2013-07 EN 61326-1:2013 X Directive 2006 /42/EC Directive 2006/42/EC of the european parliament and of the council of 17 May 2006 on machinery, and amending Directive 95/16/EC (recast) Standard complied with: DIN EN ISO 12100:2010   Intended use ICPxx ICPxx eco ICHxx C ICHxx ICHxx L ICHxx eco ICHxx L eco Compressor-cooled incubators ICP/ICP eco may be used exclu- sively for temperature testing of materials and substances in the context of the procedures and specifications described in the manual. Any other use is improper, and may result in hazards and damage. Climate chambers ICHC are suitable for stability testing of phar- maceuticals, cosmetics, food etc under long-term stable am- bient conditions. Any other use could be dangerous. Climate chambers ICH, ICH L, ICH eco and ICH L eco are suita- ble for stability testing of pharmaceuticals, cosmetics, food etc under long-term stable ambient conditions. Any other use could be dangerous. Improper use Any other use is improper and may result in hazards and damage. The appliance is not explosion-proof (does not comply with the German occupational health and safety regulation VBG 24). The appliance may only be loaded with materials and substances which cannot form any toxic or explosive vapours at the set temperature and which cannot explode, burst or ignite. The appliance may not be used for the drying, evapora- tion and burning-in of paints or similar materials, the solvents of which could form an explosive mixture when combined with air. If there is any doubt as to the composition of materials, they must not be loaded into the appliance. Potentially explosive gas-air mixtures must not form, neither in the working chamber nor in the direct vicinity of the appliance. Additionally for ICH C Only distilled water and CO2 may be fed into the chamber through the media connec- tions on the rear of the appliance. Introducing other liquids or gases is not permitted. 4 CONSTRUCTION AND DESCRIPTION memmert 1 2 3 4 5 6 Appliance overview Designation (nameplate) Connections and interfaces 1 ControlCOCKPIT 2 On/Off switch 3 Door handle 1 Type designation 2 Operating voltage 3 Applied standard 4 Protection type 5 CE conformity 1 Ethernet interface 2 Water connection (only ICHx) 3 Optional interfaces (e.g. option H5) 4 Nameplate (Door frame inside) 5 Turn control with confirmation key 6 USB interface (TwinDisplay) 6 Address of manufacturer 7 Disposal note 8 Temperature range 9 Connection / power ratings 10 Appliance number 1 2 3 5 4 4 CO2 connection (only ICHC) 5 Power connection GmbH+Co.KG D-91126 Schwabach FRG Äußere Rittersbacher Str. 38 Made in Germany memmert Schutzart DIN EN 60529 - IP 20 1 2 3 4 5 6 10 9 8 7 Typ: IN260 230 V~ 50/60 Hz DIN12880-2007-Kl.: 1 F-Nr.: B618.3008 7,4 A 1700 W Nenntemp.: 300 °C

Document Preview & Text Transcription

www.memmert.com QUICK START GUIDE КРАТКО РЪКОВОДСТВО STRUČNÁ ÚVODNÍ PŘÍRUČKA VODIČ ZA BRZI POČETAK RÖVID ÚTMUTATÓ SKRÓCONA INSTRUKCJA OBSŁUGI GHID DE PORNIRE RAPIDĂ STRUČNÁ PRÍRUČKA PRE SPUSTENIE VODNIK ZA HITRI ZAČETEK EN BG CZ HR HU PL RO SK SL ICP | ICPeco ICH | ICHeco ICH L | ICHeco L ICH C D39876 - 01/2021 2 SAFETY INSTRUCTIONS QUICK START GUIDE - ENGLISH This guide provides a brief overview of the operation of Memmert appliances and the safety regulations that you must be observed. These instructions contain only basic information that is relevant to your appliance for initial information. For detailed descriptions of individual functions, please refer to the operating manual of your appliance. Information on the type of appliance, size and power data can be obtained directly from the type plate on the appliance. Detailed instructions for your device can be found in PDF format on the supplied USB stick (only devices with TwinDISPLAY) or on the Internet at: www.memmert.com/user-manuals Always read the complete operating instructions before working with the device! Danger of suffocation. CO2 can have a suffocating effect in high con- centrations. In normal operation, the appliance emits small amounts of CO2 to its surroundings. You should therefore ensure that the room in which it is installed is properly ventilated. Always close the stop valve or pressure reducer on the gas bottle if the appliance is currently not in operation. WARNING After removing covers, live parts may be exposed. You may receive an electric shock if you touch these parts. Disconnect the mains plug be- fore removing any covers. Only electrical technicians may work on the electrical equipment of the appliances. WARNING Scan for detailed informations! Gas bottles may burst or explode at high temperatures. Keep the gas bottles away from open fl ames. Store gas bottles below 50 °C and ensure that the location is always well ventilated. Prevent water from penetrating as well as backfl ow into the gas bottles. It is essential that you read the safety notes and instructions of the gas supplier. WARNING If the door is open while the appliance is in operation, the appliance may overheat and pose a fire hazard. Do not leave the door open during operation. WARNING High concentrations of CO2 can cause cold burns or frostbite. Avoid contact with CO2 gas to the eyes and skin. CAUTION WARNING When loading the appliance with an unsuitable load, poisonous or ex- plosive vapours or gases may be produced. This could cause the appli- ance to explode, and persons could be severely injured or poisoned. The appliance may only be loaded with materials/test objects which do not form any toxic or explosive vapours when heated up. In case of appliances of a certain size, you can get accidentally locked in, which is life-threatening. Do not climb into the appliance. WARNING Risk of poisoning due to slow refrigerant leakage. If the filling quantity of CO2 is greater than the maximum filling quantity (filling quantity 375 g), a CO2 warning device and ventilation in machine rooms must be pro- vided. ICH eco/ICH L eco refrigeration systems may only be installed in rooms of at least 4 m³. WARNING UV light is a danger to your eyes. Your eyes could be injured by UV light if you do not wear protection. Always wear UV safety goggles when opening the door of the ICH L / ICH L eco. This is indicated by the warning signs on the door. WARNING Additional safety instructions for the models ICH L and ICH L eco Additional safety instructions for the models ICH C Additional safety instructions for the models ICx eco 3 GENERAL INSTRUCTIONS FOR USE Requirements of the operating personnel The appliance may only be operated and maintained by persons who are of legal age and have been instructed accordingly. Personnel who are to be trained, instructed or who are undergoing general training may only work with the appliance under the con- tinuous supervision of an experienced person. Repairs may only be performed by qua- lified electricians. The regulations in the separate service manual must be observed. Changes and alterations No unauthorised changes or alterations may be made to the appliance. No parts may be added or inserted which have not been approved by the manufacturer. Unauthori- sed modifications or changes result in the CE declaration of conformity losing its vali- dity and the appliance must no longer be operated. The manufacturer is not liable for any damage, danger or injuries that result from unauthorised changes or alterations, or from non-observance of the regulations in this manual. Behaviour in case of malfunctions and irregularities The appliance may only be used in a flawless condition. If you as the operator notice irregularities,malfunctions or damage, immediately take the appliance out of service and inform your superior. Switching off the appliance in an emergency Push the On/Off switch on the control panel and dis- connect power plug. This disconnects the appliance from the power supply at all poles. Applied directives and standards X Directive 2014/30/EU amended Directive of the council for harmonisation of the laws of the member states on elec- tromagnetic compatibility. Standards complied with: DIN EN 61326-1:2013-07 EN 61326-1:2013 X Directive 2006 /42/EC Directive 2006/42/EC of the european parliament and of the council of 17 May 2006 on machinery, and amending Directive 95/16/EC (recast) Standard complied with: DIN EN ISO 12100:2010   Intended use ICPxx ICPxx eco ICHxx C ICHxx ICHxx L ICHxx eco ICHxx L eco Compressor-cooled incubators ICP/ICP eco may be used exclu- sively for temperature testing of materials and substances in the context of the procedures and specifications described in the manual. Any other use is improper, and may result in hazards and damage. Climate chambers ICHC are suitable for stability testing of phar- maceuticals, cosmetics, food etc under long-term stable am- bient conditions. Any other use could be dangerous. Climate chambers ICH, ICH L, ICH eco and ICH L eco are suita- ble for stability testing of pharmaceuticals, cosmetics, food etc under long-term stable ambient conditions. Any other use could be dangerous. Improper use Any other use is improper and may result in hazards and damage. The appliance is not explosion-proof (does not comply with the German occupational health and safety regulation VBG 24). The appliance may only be loaded with materials and substances which cannot form any toxic or explosive vapours at the set temperature and which cannot explode, burst or ignite. The appliance may not be used for the drying, evapora- tion and burning-in of paints or similar materials, the solvents of which could form an explosive mixture when combined with air. If there is any doubt as to the composition of materials, they must not be loaded into the appliance. Potentially explosive gas-air mixtures must not form, neither in the working chamber nor in the direct vicinity of the appliance. Additionally for ICH C Only distilled water and CO2 may be fed into the chamber through the media connec- tions on the rear of the appliance. Introducing other liquids or gases is not permitted. 4 CONSTRUCTION AND DESCRIPTION memmert 1 2 3 4 5 6 Appliance overview Designation (nameplate) Connections and interfaces 1 ControlCOCKPIT 2 On/Off switch 3 Door handle 1 Type designation 2 Operating voltage 3 Applied standard 4 Protection type 5 CE conformity 1 Ethernet interface 2 Water connection (only ICHx) 3 Optional interfaces (e.g. option H5) 4 Nameplate (Door frame inside) 5 Turn control with confirmation key 6 USB interface (TwinDisplay) 6 Address of manufacturer 7 Disposal note 8 Temperature range 9 Connection / power ratings 10 Appliance number 1 2 3 5 4 4 CO2 connection (only ICHC) 5 Power connection GmbH+Co.KG D-91126 Schwabach FRG Äußere Rittersbacher Str. 38 Made in Germany memmert Schutzart DIN EN 60529 - IP 20 1 2 3 4 5 6 10 9 8 7 Typ: IN260 230 V~ 50/60 Hz DIN12880-2007-Kl.: 1 F-Nr.: B618.3008 7,4 A 1700 W Nenntemp.: 300 °C

Document Preview & Text Transcription

www.memmert.com ICP | ICPeco ICH | ICHeco ICH L | ICHeco L ICH C QUICK START GUIDE HURTIG STARTVEJLEDNING LÜHIJUHEND PIKAOPAS GREITOS PRADŽIOS VADOVAS ĪSĀ LIETOŠANAS PAMĀCĪBA HURTIGSTARTVEILEDNING SNABBSTARTSGUIDE EN DA ET FI LT LV NO SE D39877 - 01/2021 2 SAFETY INSTRUCTIONS QUICK START GUIDE - ENGLISH This guide provides a brief overview of the operation of Memmert appliances and the safety regulations that you must be observed. These instructions contain only basic information that is relevant to your appliance for initial information. For detailed descriptions of individual functions, please refer to the operating manual of your appliance. Information on the type of appliance, size and power data can be obtained directly from the type plate on the appliance. Detailed instructions for your device can be found in PDF format on the supplied USB stick (only devices with TwinDISPLAY) or on the Internet at: www.memmert.com/user-manuals Always read the complete operating instructions before working with the device! Danger of suffocation. CO2 can have a suffocating effect in high con- centrations. In normal operation, the appliance emits small amounts of CO2 to its surroundings. You should therefore ensure that the room in which it is installed is properly ventilated. Always close the stop valve or pressure reducer on the gas bottle if the appliance is currently not in operation. WARNING After removing covers, live parts may be exposed. You may receive an electric shock if you touch these parts. Disconnect the mains plug be- fore removing any covers. Only electrical technicians may work on the electrical equipment of the appliances. WARNING Scan for detailed informations! Gas bottles may burst or explode at high temperatures. Keep the gas bottles away from open fl ames. Store gas bottles below 50 °C and ensure that the location is always well ventilated. Prevent water from penetrating as well as backfl ow into the gas bottles. It is essential that you read the safety notes and instructions of the gas supplier. WARNING If the door is open while the appliance is in operation, the appliance may overheat and pose a fire hazard. Do not leave the door open during operation. WARNING High concentrations of CO2 can cause cold burns or frostbite. Avoid contact with CO2 gas to the eyes and skin. CAUTION WARNING When loading the appliance with an unsuitable load, poisonous or ex- plosive vapours or gases may be produced. This could cause the appli- ance to explode, and persons could be severely injured or poisoned. The appliance may only be loaded with materials/test objects which do not form any toxic or explosive vapours when heated up. In case of appliances of a certain size, you can get accidentally locked in, which is life-threatening. Do not climb into the appliance. WARNING Risk of poisoning due to slow refrigerant leakage. If the filling quanti- ty of CO2 is greater than the maximum filling quantity (filling quantity 375g), a CO2 warning device and ventilation in machine rooms must be provided. ICH eco/ICH L eco refrigeration systems may only be instal- led in rooms of at least 4 m³. WARNING UV light is a danger to your eyes. Your eyes could be injured by UV light if you do not wear protection. Always wear UV safety goggles when opening the door of the ICH L / ICH L eco. This is indicated by the warning signs on the door. WARNING Additional safety instructions for the models ICH L and ICH L eco Additional safety instructions for the models ICH C Additional safety instructions for the models ICx eco 3 GENERAL INSTRUCTIONS FOR USE Requirements of the operating personnel The appliance may only be operated and maintained by persons who are of legal age and have been instructed accordingly. Personnel who are to be trained, instructed or who are undergoing general training may only work with the appliance under the con- tinuous supervision of an experienced person. Repairs may only be performed by qua- lified electricians. The regulations in the separate service manual must be observed. Changes and alterations No unauthorised changes or alterations may be made to the appliance. No parts may be added or inserted which have not been approved by the manufacturer. Unauthori- sed modifications or changes result in the CE declaration of conformity losing its vali- dity and the appliance must no longer be operated. The manufacturer is not liable for any damage, danger or injuries that result from unauthorised changes or alterations, or from non-observance of the regulations in this manual. Behaviour in case of malfunctions and irregularities The appliance may only be used in a flawless condition. If you as the operator notice irregularities,malfunctions or damage, immediately take the appliance out of service and inform your superior. Switching off the appliance in an emergency Push the On/Off switch on the control panel and disconnect power plug. This disconnects the ap- pliance from the power supply at all poles. Applied directives and standards X Directive 2014/30/EU amended Directive of the council for harmonisation of the laws of the member states on elec- tromagnetic compatibility. Standards complied with: DIN EN 61326-1:2013-07 EN 61326-1:2013 X Directive 2006 /42/EC Directive 2006/42/EC of the european parliament and of the council of 17 May 2006 on machinery, and amending Directive 95/16/EC (recast) Standard complied with: DIN EN ISO 12100:2010   Intended use ICPxx ICPxx eco ICHxx C ICHxx ICHxx L ICHxx eco ICHxx L eco Compressor-cooled incubators ICP/ICP eco may be used exclu- sively for temperature testing of materials and substances in the context of the procedures and specifications described in the manual. Any other use is improper, and may result in hazards and damage. Climate chambers ICHC are suitable for stability testing of phar- maceuticals, cosmetics, food etc under long-term stable am- bient conditions. Any other use could be dangerous. Climate chambers ICH, ICH L, ICH eco and ICH L eco are suita- ble for stability testing of pharmaceuticals, cosmetics, food etc under long-term stable ambient conditions. Any other use could be dangerous. Improper use Any other use is improper and may result in hazards and damage. The appliance is not explosion-proof (does not comply with the German occupational health and safety regulation VBG 24). The appliance may only be loaded with materials and substances which cannot form any toxic or explosive vapours at the set temperature and which cannot explode, burst or ignite. The appliance may not be used for the drying, evapora- tion and burning-in of paints or similar materials, the solvents of which could form an explosive mixture when combined with air. If there is any doubt as to the composition of materials, they must not be loaded into the appliance. Potentially explosive gas-air mixtures must not form, neither in the working chamber nor in the direct vicinity of the appliance. Additionally for ICH C Only distilled water and CO2 may be fed into the chamber through the media connec- tions on the rear of the appliance. Introducing other liquids or gases is not permitted. 4 CONSTRUCTION AND DESCRIPTION memmert 1 2 3 4 5 6 Appliance overview Designation (nameplate) Connections and interfaces 1 ControlCOCKPIT 2 On/Off switch 3 Door handle 1 Type designation 2 Operating voltage 3 Applied standard 4 Protection type 5 CE conformity 1 Ethernet interface 2 Water connection (only ICHx) 3 Optional interfaces (e.g. option H5) 4 Nameplate (Door frame inside) 5 Turn control with confirmation key 6 USB interface (TwinDisplay) 6 Address of manufacturer 7 Disposal note 8 Temperature range 9 Connection / power ratings 10 Appliance number 1 2 3 5 4 4 CO2 connection (only ICHC) 5 Power connection GmbH+Co.KG D-91126 Schwabach FRG Äußere Rittersbacher Str. 38 Made in Germany memmert Schutzart DIN EN 60529 - IP 20 1 2 3 4 5 6 10 9 8 7 Typ: IN260 230 V~ 50/60 Hz DIN12880-2007-Kl.: 1 F-Nr.: B618.3008 7,4 A 1700 W Nenntemp.: 300 °C

Document Preview & Text Transcription

www.memmert.com ICP | ICPeco ICH | ICHeco ICH L | ICHeco L ICH C QUICK START GUIDE KURZANLEITUNG GUÍA RÁPIDA MODE D‘EMPLOI RAPIDE ISTRUZIONI BREVI GUIA RÁPIDO BEKNOPTE HANDLEIDING EN DE ES FR IT PT NL D39878 - 01/2021 2 SAFETY INSTRUCTIONS QUICK START GUIDE - ENGLISH This guide provides a brief overview of the operation of Memmert appliances and the safety regulations that you must be observed. These instructions contain only basic information that is relevant to your appliance for initial information. For detailed descriptions of individual functions, please refer to the operating manual of your appliance. Information on the type of appliance, size and power data can be obtained directly from the type plate on the appliance. Detailed instructions for your device can be found in PDF format on the supplied USB stick (only devices with TwinDISPLAY) or on the Internet at: www.memmert.com/user-manuals Always read the complete operating instructions before working with the device! Danger of suffocation. CO2 can have a suffocating effect in high con- centrations. In normal operation, the appliance emits small amounts of CO2 to its surroundings. You should therefore ensure that the room in which it is installed is properly ventilated. Always close the stop valve or pressure reducer on the gas bottle if the appliance is currently not in operation. WARNING After removing covers, live parts may be exposed. You may receive an electric shock if you touch these parts. Disconnect the mains plug be- fore removing any covers. Only electrical technicians may work on the electrical equipment of the appliances. WARNING Scan for detailed informations! Gas bottles may burst or explode at high temperatures. Keep the gas bottles away from open fl ames. Store gas bottles below 50 °C and ensure that the location is always well ventilated. Prevent water from penetrating as well as backfl ow into the gas bottles. It is essential that you read the safety notes and instructions of the gas supplier. WARNING If the door is open while the appliance is in operation, the appliance may overheat and pose a fire hazard. Do not leave the door open during operation. WARNING High concentrations of CO2 can cause cold burns or frostbite. Avoid contact with CO2 gas to the eyes and skin. CAUTION WARNING When loading the appliance with an unsuitable load, poisonous or ex- plosive vapours or gases may be produced. This could cause the appli- ance to explode, and persons could be severely injured or poisoned. The appliance may only be loaded with materials/test objects which do not form any toxic or explosive vapours when heated up. In case of appliances of a certain size, you can get accidentally locked in, which is life-threatening. Do not climb into the appliance. WARNING Risk of poisoning due to slow refrigerant leakage. If the filling quantity of CO2 is greater than the maximum filling quantity (filling quantity 375 g), a CO2 warning device and ventilation in machine rooms must be pro- vided. ICH eco/ICH L eco refrigeration systems may only be installed in rooms of at least 4 m³. WARNING UV light is a danger to your eyes. Your eyes could be injured by UV light if you do not wear protection. Always wear UV safety goggles when opening the door of the ICH L / ICH L eco. This is indicated by the warning signs on the door. WARNING Additional safety instructions for the models ICH L and ICH L eco Additional safety instructions for the models ICH C Additional safety instructions for the models ICx eco 3 GENERAL INSTRUCTIONS FOR USE Requirements of the operating personnel The appliance may only be operated and maintained by persons who are of legal age and have been instructed accordingly. Personnel who are to be trained, instructed or who are undergoing general training may only work with the appliance under the con- tinuous supervision of an experienced person. Repairs may only be performed by qua- lified electricians. The regulations in the separate service manual must be observed. Changes and alterations No unauthorised changes or alterations may be made to the appliance. No parts may be added or inserted which have not been approved by the manufacturer. Unauthori- sed modifications or changes result in the CE declaration of conformity losing its vali- dity and the appliance must no longer be operated. The manufacturer is not liable for any damage, danger or injuries that result from unauthorised changes or alterations, or from non-observance of the regulations in this manual. Behaviour in case of malfunctions and irregularities The appliance may only be used in a flawless condition. If you as the operator notice irregularities,malfunctions or damage, immediately take the appliance out of service and inform your superior. Switching off the appliance in an emergency Push the On/Off switch on the control panel and disconnect power plug. This disconnects the ap- pliance from the power supply at all poles. Applied directives and standards X Directive 2014/30/EU amended Directive of the council for harmonisation of the laws of the member states on elec- tromagnetic compatibility. Standards complied with: DIN EN 61326-1:2013-07 EN 61326-1:2013 X Directive 2006 /42/EC Directive 2006/42/EC of the european parliament and of the council of 17 May 2006 on machinery, and amending Directive 95/16/EC (recast) Standard complied with: DIN EN ISO 12100:2010   Intended use ICPxx ICPxx eco ICHxx C ICHxx ICHxx L ICHxx eco ICHxx L eco Compressor-cooled incubators ICP/ICP eco may be used exclu- sively for temperature testing of materials and substances in the context of the procedures and specifications described in the manual. Any other use is improper, and may result in hazards and damage. Climate chambers ICHC are suitable for stability testing of phar- maceuticals, cosmetics, food etc under long-term stable am- bient conditions. Any other use could be dangerous. Climate chambers ICH, ICH L, ICH eco and ICH L eco are suita- ble for stability testing of pharmaceuticals, cosmetics, food etc under long-term stable ambient conditions. Any other use could be dangerous. Improper use Any other use is improper and may result in hazards and damage. The appliance is not explosion-proof (does not comply with the German occupational health and safety regulation VBG 24). The appliance may only be loaded with materials and substances which cannot form any toxic or explosive vapours at the set temperature and which cannot explode, burst or ignite. The appliance may not be used for the drying, evapora- tion and burning-in of paints or similar materials, the solvents of which could form an explosive mixture when combined with air. If there is any doubt as to the composition of materials, they must not be loaded into the appliance. Potentially explosive gas-air mixtures must not form, neither in the working chamber nor in the direct vicinity of the appliance. Additionally for ICH C Only distilled water and CO2 may be fed into the chamber through the media connec- tions on the rear of the appliance. Introducing other liquids or gases is not permitted. 4 CONSTRUCTION AND DESCRIPTION memmert 1 2 3 4 5 6 Appliance overview Designation (nameplate) Connections and interfaces 1 ControlCOCKPIT 2 On/Off switch 3 Door handle 1 Type designation 2 Operating voltage 3 Applied standard 4 Protection type 5 CE conformity 1 Ethernet interface 2 Water connection (only ICHx) 3 Optional interfaces (e.g. option H5) 4 Nameplate (Door frame inside) 5 Turn control with confirmation key 6 USB interface (TwinDisplay) 6 Address of manufacturer 7 Disposal note 8 Temperature range 9 Connection / power ratings 10 Appliance number 1 2 3 5 4 4 CO2 connection (only ICHC) 5 Power connection GmbH+Co.KG D-91126 Schwabach FRG Äußere Rittersbacher Str. 38 Made in Germany memmert Schutzart DIN EN 60529 - IP 20 1 2 3 4 5 6 10 9 8 7 Typ: IN260 230 V~ 50/60 Hz DIN12880-2007-Kl.: 1 F-Nr.: B618.3008 7,4 A 1700 W Nenntemp.: 300 °C