Memmert UF160TS Manuals

1 pdf manual(s) Memmert UF160TS for free download (Document Types: Assembly instructions manual)

Document Preview & Text Transcription

www.memmert.com | www.atmosafe.net 100% ATMOSAFE. MADE IN GERMANY. Assembly INSTRUCTIONS Installing jambs for a pass-through oven MEMMERT GmbH + Co. KG Willi-Memmert-Straße 90-96 D-91186 Büchenbach Germany Phone: +49 (0)9122 925-0 Fax: +49 (0)9122 14585 E-mail: [email protected] Internet: www.memmert.com Customer service: Hotline: +49 (0)9171 9792 911 Service fax: +49 (0)9171 9792 979 E-mail: [email protected] © 2017 Memmert GmbH + Co. KG 2 1. Introduction Wall jambs protect the cleanroom from contamination by foreign matter from the grey- room when the Memmert pass-through ovens UF...TS are in operation. These instructions will guide you through the process of positioning the appliance in the cleanroom and installing the wall jambs. Fig. 1 Pass-through oven UF750TS with wall jamb – view from the cleanroom side 2. Scope of delivery / required parts Component Qty. Part number for appliance ... UF160TS UF260TS UF450TS UF750TS Assembly 1 B33204 B33205 B33206 B33027 Assembly consists of: Side panel, left jamb (cleanroom side) 1 E38307 E38311 E38307 E37410 Side panel, right jamb (cleanroom side) 1 E38308 E38312 E38308 E37417 Upper frame section, jamb (cleanroom side) 1 E38323 E38310 E38330 E38330 Side panel, left jamb (greyroom side) 1 E38303 E38316 E38303 E37414 Side panel, right jamb (greyroom side) 1 E38302 E38315 E38302 E37415 Upper frame section, jamb (greyroom side) 1 E38321 E38317 E38327 E38327 Screw connection M3 x 6 Torx 60 E05772 E05772 E05772 E05772 3. Required tools and equipment ► Torx screwdriver size 15 ► Cordless screwdriver ► Silicone for grouting (optional) ► Ø 2.5 mm countersink drill, small D33469 | 04/2018 MEMMERT GmbH + Co. KG Willi-Memmert-Straße 90-96 D-91186 Büchenbach Germany Phone: +49 (0)9122 925-0 Fax: +49 (0)9122 14585 E-mail: [email protected] Internet: www.memmert.com Customer service: Hotline: +49 (0)9171 9792 911 Service fax: +49 (0)9171 9792 979 E-mail: [email protected] © 2017 Memmert GmbH + Co. KG 3 4. Preparing the wall cut-out When making the wall cut-out, ensure that its size is between the minimum and maximum dimensions. If the wall cut-out is too small, the appliance cannot be positioned. If the cut-out is too large, the cleanroom will not be sealed properly. The wall has to be at least 100 mm thick and must not be thicker than 300 mm. This is important to ensure that the service cover on the appliance top is accessible. If several units are installed next to each other in the wall, the distance between the units must be at least 300 mm due to the frame width. The following minimum and maximum dimensions apply for the pass-through ovens UF160TS, UF260TS, UF450TS and UF750TS, which are usually installed on the floor. Legend: Wall Tolerance zone Cut-out Wall cut-out dimensions for an UF160TS appliance: � 825 mm � 870 mm 22.5 mm 22.5 mm 25 mm ������ mm ������ mm The width allowance is 22.5 mm on each side, i.e. 45 mm in total. The height allowance is 25 mm. D33469 | 04/2018 MEMMERT GmbH + Co. KG Willi-Memmert-Straße 90-96 D-91186 Büchenbach Germany Phone: +49 (0)9122 925-0 Fax: +49 (0)9122 14585 E-mail: [email protected] Internet: www.memmert.com Customer service: Hotline: +49 (0)9171 9792 911 Service fax: +49 (0)9171 9792 979 E-mail: [email protected] © 2017 Memmert GmbH + Co. KG 4 Wall cut-out dimensions for an UF260TS appliance: � 905 mm � 950 mm 22.5 mm 22.5 mm 30 mm ������ mm ������ mm The width allowance is 22.5 mm on each side, i.e. 45 mm in total. The height allowance is 30 mm. Wall cut-out dimensions for an UF450TS appliance: � 1305 mm � 1350 mm 22.5 mm 22.5 mm 27 mm ������ mm ������ mm The width allowance is 22.5 mm on each side, i.e. 45 mm in total. D33469 | 04/2018