Mercado Medic REAL 8100 Manuals
1 pdf manual(s) Mercado Medic REAL 8100 for free download (Document Types: User and care instructions)
Mercado Medic REAL 8100 User and care instructions [PDF] (2 pages)
- Identifier: id-855379
- Brand: Mercado Medic
- Device: REAL 8100 Medical Equipment
- Type: PDF
- Key Aspects: Operational Mode Explanations, Basic Configuration Guidelines, Warranty and Service Information
- UPD Date: 24.06.2026
- Source File: 889197.pdf
- Pages: 2
- Description: Product setup manual for the Mercado Medic REAL 8100.
Click to expand and read text
Seat tilt adjustment is available in two models: crank or electrically regulated. For the crank regulated seat, the angle is adjusted using the knob (1). The tilt increments (+15˚/-8˚) can be fixed using the nuts (2). Electric tilt adjustment can be regulated using the remote control. Press the left button (3) to incline the seat forwards, and the right button (7) to incline the seat backwards. REAL 8100 r The REAL chair has replaceable components, accessories, and functions with setting options which allow individual adjustment. The chair must only be used by the person and the purpose for which it is intended. The chair is designed for indoor use and must not be exposed to water, other liquids or chemicals. The chair must not be exposed to intensive sunlight for any length of time. The chair must not be fitted with accessories or components other than those approved by Mercado Medic AB Repair and other technical actions must only be carried out by personnel authorised by Mercado Medic AB. Read this user instruction carefully before using the chair. USER and CARE INSTRUCTIONS Sitting height Brake Seat tilting Article No: April 2008 Crank regulated The sitting height is adjusted using a remote control. The remote control is equipped with either two buttons (the chair only has electric raising/lowering) or eight buttons (in addition to electric raising/lowering, the chair also has electric seat tilting and electric brake). To raise the seat - press the left button on the remote control (top row). To lower the seat – press the right button on the remote control (top row). NB! If the remote control has more than two buttons (eight buttons with additional electric functions), the raising/lowering functions are located in the second top row. 1 2 Chair with electric function, for X-ray The brake is regulated using the foot pedal, the handbrake lever or electrically (via the remote control). To lock: Press the foot pedal (1) located to the left of the brake shaft, until the brake foot touches the floor and has locked. To brake the chair using the handbrake lever – move this backwards until the brake foot touches the floor and is locked. The handbrake lever may be positioned on either side of the chair. If the chair has an electric brake - press the lowest button on the left of the remote control (4) to brake or to release the brake. Attention! The brake must always be locked when sitting down and standing up from the chair. The brake must be checked regularly. If worn, replace the rubber brake feet (2). The brake function may be less effective on uneven surfaces. To correctly calibrate the chair with respect to the investigative equipment, place the brake leg in the pre-installed positioning cups in the clinic floor. 2 Class REAL 8100 is classified as protection class II, Internal battery. REAL 8100 is classified as protection type B. REAL 8100 has been EMC tested and proven in accordance with EN 60601-1-1 and EN 60601-1-2, and must therefore be used in accordance with our User and care instructions. Mobile telephones or other RF communication equipment can interfere with the REAL 8100. Max. user weight: 150 kg.) The chair must be transported in designated boxes on pallets, and must be stored indoors at min. +10ºC. Only electrical equipment from Mercado Medic AB is permitted for use with the REAL 8100. Note! The electric functions on the electric chair may only be used a maximum of 10% of the time (max 6 min/h). If this limit is exceeded the chair can be damaged. This symbol warns of the danger of crushing. PLEASE NOTE: Only the person seated in the chair is allowed any contact with the chair whilst using electrical functions. ! ! ! ! 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 remote control units
Mercado Medic REAL 8100: Medical Equipment Category Related Instructions
User operation guide for the Huntleigh Smartsigns Liteplus Medical Equipment. It offers guidance for setup and wiring setup, installation, usage examples, performance optimization.
Instructions for Use enPuls Version 2.0 EN User instruction booklet for the Zimmer enPuls Medical Equipment. The manual covers procedures for firmware installation, device safety checks, daily usage.
US0208-INS-LAB-RevD11 MODEL US0208 / US0208PL SEMI-ELECTRIC BED MODEL US0458 / US0458PL FULL-ELECTRIC / LOW BED USER MANUAL READ THIS MANUAL BEFORE OPERATING THE PATRIOT™ HOMECARE BED. SAVE THIS MANUAL FOR FUTURE USE. INFO: THE MOST CURRENT VERSION OF THIS M Owner’s guide for the Lumex PATRIOT US0458 Medical Equipment. It explains installation, setup, and system setup, hardware components, testing procedures.
Gebrauchsanweisung ................................................................ 3 Instructions for Use ................................................................... 8 Instructions d'utilisation ........................................................ Quick reference guide for the Otto Bock 6A53 Medical Equipment. It describes operating procedures and operation, setup, installation steps.