Mitsubishi Electric MELSEC L Seies Manuals
1 pdf manual(s) Mitsubishi Electric MELSEC L Seies for free download (Document Types: Installation manual)
Mitsubishi Electric MELSEC L Seies Installation manual [PDF] (36 pages)
- Identifier: id-2329345
- Brand: Mitsubishi Electric
- Device: MELSEC L Seies I/O Systems
- Type: PDF
- Key Aspects: Pre-Installation Safety Requirements, Routine Functionality Testing, Performance Optimization Tips
- UPD Date: 02.04.2026
- Source File: 1958260.pdf
- Pages: 36
- Description: Installation instructions for the Mitsubishi Electric MELSEC L Seies.
Click to expand and read text
Programmable Controllers Installation Manual for digital Input and Output Modules Art. no.: 260563, ENG, Version B, 14012013 Safety Information For qualified staff only This manual is only intended for use by properly trained and qualified electri- cal technicians who are fully acquainted with automation technology safety standards. All work with the hardware described, including system design, installation, setup, maintenance, service and testing, may only be performed by trained electrical technicians with approved qualifications who are fully acquainted with the applicable automation technology safety standards and regulations. Proper use of equipment The programmable controllers (PLC) of the MELSEC L series are only intended for the specific applications explicitly described in this manual or the manuals listed below. Please take care to observe all the installation and operating parameters specified in the manual. All products are designed, manufactured, tested and documented in agreement with the safety regulations. Any modi- fication of the hardware or software or disregarding of the safety warnings given in this manual or printed on the product can cause injury to persons or damage to equipment or other property. Only peripherals and expansion equipment specifically recommended and approved by Mitsubishi Electric may be used with the programmable controllers of the MELSEC L series. Any other use or application of the products is deemed to be improper. Relevant safety regulations All safety and accident prevention regulations relevant to your specific appli- cation must be observed in the system design, installation, setup, mainte- nance, servicing and testing of these products. In this manual special warnings that are important for the proper and safe use of the products are clearly identified as follows: Further information The following manuals contain further information about the module: ● Instruction leaflet “Before Using the Product” for LX10, LX28, LX40C6, LX41C4, LX42C4, LY10R2, LY20S6, LY40NT5P, LY41NT1P, LY42NT1P, LY40PT5P, LY41PT1P and LY42PT1P ● MELSEC L series I/O Module User's Manual ● MELSEC L series CPU Module User's Manual (Hardware Design, Maintenance and Inspection) ● MELSEC System Q/L series Programming Manual ● Safety Guidelines for MELSEC L series CPU These manuals are available free of charge through the internet (https://eu3a.mitsubishielectric.com). If you have any questions concerning the installation, configuration or opera- tion of the equipment described in this manual, please contact your relevant sales office or department. I/O Modules Overview of the Modules Part Names � Operate the switch with your fingers. Do not use a screwdriver or similar tool as it may damage the switch. Pin arrangement of the terminal block The terminal block is shown in module front view. Pin arrangement of the connectors The connectors are shown in module front view. ● 40-pin connector ● 2x40-pin connector Dimensions ● Modules with terminal block ● Modules with connector(s) Specifications General specifications Further general specifications can be found in the Safety Guidelines for MELSEC L series CPU. P DANGER: Personnel health and injury warnings. Failure to observe the precautions described here can result in serious health and injury hazards. E CAUTION: Equipment and property damage warnings. Failure to observe the precautions described here can result in serious damage to the equipment or other property. Module Input/output points I/O- Connection Number Type LX10 16 Inputs AC Terminal block LX28 8 Inputs Terminal block LX40C6 16 Inputs DC (positive/ negative common) Terminal block LX41C4 32 Inputs 40-pin connector LX42C4 64 Inputs 2x40-pin connector LY10R2 16 Outputs Relay contact Terminal block LY20S6 16 Outputs Triac Terminal block LY40NT5P 16 Outputs Transistor (sink) Terminal block LY41NT1P 32 Outputs 40-pin connector LY42NT1P 64 Outputs 2x40-pin connector LY40PT5P 16 Outputs Transistor (source) Terminal block LY41PT1P 32 Outputs 40-pin connector LY42PT1P 64 Outputs 2x40-pin connector No. Description � Module joint lever (for connecting two modules) � I/O status LEDs Indicates the I/O status ON: I/O signal is ON OFF: I/O signal is OFF � Terminal block (removable) 18-point terminal block for connecting I/O signal cables to/from external devices � Terminal cover � Indication selector switch� Used to switch the I/O status LED indication between the first 32 points and the second 32 points of a 64-point module. � I/O Connector(s) (40 pins) Connector(s) for I/O signal cables to/from external devices. � Serial number plate � DIN rail mounting hook (at the backside of the module) � � � � � � � � � � � � � 18-point screw terminal block type 40-pin connector type 2x40-pin connector type � � � � � � � 8-point type 16-point type A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 2A1 2A2 2A3 2A4 2A5 2A6 2A7 2A8 2A9 2A10 2A11 2A12 2A13 2A14 2A15 2A16 2A17 2A18 2A19 2A20 2B1 2B2 2B3 2B4 2B5 2B6 2B7 2B8 2B9 2B10 2B11 2B12 2B13 2B14 2B15 2B16 2B17 2B18 2B19 2B20 1A1 1A2 1A3 1A4 1A5 1A6 1A7 1A8 1A9 1A10 1A11 1A12 1A13 1A14 1A15 1A16 1A17 1A18 1A19 1A20 1B1 1B2 1B3 1B4 1B5 1B6 1B7 1B8 1B9 1B10 1B11 1B12 1B13 1B14 1B15 1B16 1B17 1B18 1B19 1B20 Item Specifications Ambient temperature when operating 0 to 55 °C when stored –25 to 75 °C Ambient humidity when operating 5 to 95 % RH (no condensation) Working atmosphere Free from corrosive or flammable gas and excessive conductive dusts Installation location Inside control panel DIN rail centre 45 45 95 117 4 4 90 4 28.5 All dimensions are in “mm” DIN rail centre 45 45 95 4 4 90 4 28.5 All dimensions are in “mm”
Mitsubishi Electric MELSEC L Seies: I/O Systems Category Related Instructions
Type designation Product description I N S T A L L A T I O N M A N U A L Catalog no. from software version Document no. 560-310 I/O module 1.0 jiqc10en1-b (1301) IO1000 I/O module Comprehensive guide for the Inficon IO1000 I/O Systems. It provides technical information on setup tips, service procedures, control functions, support details.
(217) 352-9330 | [email protected] | artisantg.com -~ ARTISAN® ~I TECHNOLOGY GROUP Your definitive source for quality pre-owned equipment. Artisan Technology Group Full-service, independent repair center with experienced engineers and technicians on staff. Operation and maintenance manual for the Acromag 948 Series I/O Systems. The manual guides users through installation, system setup, maintenance schedule.
CZ Foxtrot EN C-IT-0908S Modul 9 vstupů a 8 výstupů Module with 9 inputs and 8 outputs Základní dokumentace TXN 133 52 Basic documentation 1 Popis a parametry Description and parameters Modul C-IT-0908S (obj. č.: TXN 133 52) je určen pro připojení Technical reference manual for the TECO Foxtrot C-IT-0908S I/O Systems. The document highlights operating procedures and installation guides, network setup, operating modes, control functions.
Right choice for ultimate yield LSIS strives to maximize customers' profit in gratitude of choosing us for your partner. Programmable Logic Controller BACnet/IP I/F Module User’s Manual Read this manual carefully before installing, wiring, operating, ser Installation and operation manual for the LSIS XGT Series Control Unit. This documentation details procedures for energy usage, functional overview, operating modes.