Document Preview & Text Transcription (Main Page)
Click to expand and read text
KEYPAD FUNCTION ON/OFF: Turns pump on and off. When the pump is running, the PAUSE key must be used to stop infusion first. Then press the OFF key to turn pump off. RUN/PAUSE: Starts or pauses the pump. When the pump is paused, pressing this key will resume pumping. UP ARROW/ DOWN ARROW: Used to scroll through the dis- play screens. NO/CHANGE: Rejects highlighted data. YES/ ENTER: Accepts highlighted data. HELP/OPTIONS: Used to request and exit help screen when pump is paused, or go to options screen when pump is run- ning. ./SILENCE: Used to silence alarm for 1 minute intervals, and as a decimal point. PRIME/BOLUS: Used to prime fluid through the tubing to clear it of air. LED INDICATORS Green- pump is running Yellow- standby Red- pump in alarm status MOOG MEDICAL DEVICES GROUP Curlin 6000 Series™ V2.01 Ambulatory Infusion Pumps Clinician’s Guide CONTINUOUS THERAPY REFER TO USER’S MANUAL FOR DETAILED INSTRUCTIONS OPTIONS 1 LOCK: Press NO to change Lock Setting (may need access code). Press YES to accept new setting. 2 HOURLY TOTAL Press NO then YES to view. Scroll to review each hour’s totals. Press NO to exit. 3 CLEAR HOURLY: Press NO then YES to view. Press YES to clear, NO to retain and exit. 4 MedLMTS: (Appears only if previously selected) Press NO to change, YES to accept, enter new rate and press YES to accept. 5 DOWN OCCLUSION: Press NO to change, YES to accept. 6 AIR SENSITIVITY: Press NO to change, YES to accept. 7 AUDIO: Press 1-9 to hear level, press YES to accept. 8 POWER CHECK: Press NO then YES to check level. 9 ACCEPT OPT? Press YES to accept any changes made. HOW TO CHANGE THE LOCK SETTING 1 Lock may be initially selected in BIOMED SETUP. 2 When infusing, press OPTIONS key. 3 Scroll to LOCK and press NO to change. 4 Enter access code at prompt. 5 Select NO until the desired lock setting is obtained. 6 Press YES/ENTER to select. 7 Exit Options menu by pressing YES at “ACCEPT OPT?” field. INSTALLING BATTERIES 1 Turn pump OFF or connect to AC adapter. 2 Open the battery door on the back of pump. 3 Insert 2 new “C” size alkaline (Duracell ProCell) batteries bottom side first with both positive poles at the top of the battery compartment. 4 Slide the battery compartment door back into place. USING THE HELP FUNCTIONS 1 When programming, press the HELP key. While running, press PAUSE, then press HELP key. 2 When a HELP screen is displayed and there is more text to read that is not displayed on the screen, or icons will appear, scroll up and down the text using the ARROW keys. 3 When finished, press the HELP key again to exit the HELP screen. Moog Medical Devices Group tf 800.970.2337 4314 Zevex Park Lane ph 801.264.1001 Salt Lake City, Utah 84123 USA fx 801.264.1051 www.moog.com/medical Moog is a registered trademark of Moog, Inc. and its subsidiaries. All trademarks indicated herein are the property of Moog, Inc. and its subsidiaries. © 2011 Moog, Inc. All rights reserved. 46258 Rev. A LCD DISPLAY RESOLUTION INFUSION COMPLETE Press PAUSE, add another IV bag, select REPEAT Rx and confirm fields, or turn the pump off. ALARM AIR-IN-LINE Remove air from administration set and IV bag. (Disconnect set from patient’s access site prior to using prime function.) ALARM DOWN OCCLUSION Check administration set from the pump to patient’s access site for cause of occlusion. Correct obstruc- tion per protocol. Consider changing the pressure setting from Low to High. When occlusion is resolved, the alarm will stop and pumping will resume. ALARM UP OCCLUSION Check administration set from IV bag to pump for cause of occlusion. When ready to begin infusion, press PAUSE, select RESUME, and press RUN. ALARM HIGH UP PRESSURE Check for excessive pressure on IV bag. When ready to begin infusion, press PAUSE, select RESUME, and press RUN. ALARM SET NOT INSTALLED Install appropriate Curlin Medical administration set. Use ONLY Curlin Medical administration sets. See User’s Manual or IV set directions for proper installation instructions. ALARM UNATTENDED PUMP To resolve, press RUN and resume the therapy or continue with operating procedure. ALARM REPLACE SET 3 Replace set, prime set if necessary, select RESUME and press RUN when ready to begin. ALARM DOOR OPEN Check placement of administration set and close pump door properly. See User’s Manual for instructions. ALARM EMPTY BATTERY Press the pause key and turn pump off. Install 2 new “C” size alkaline batteries. ERROR CODE If an error code occurs, turn pump off and consult provider or manufacturer. PUMP ALARMS & RESOLUTIONS
Moog PainSmart IOD Operation & user’s manual Thumbnail

Moog PainSmart IOD Operation & user’s manual [PDF] (2 pages)

  • Identifier: id-2125316
  • Brand: Moog
  • Device: Moog PainSmart IOD Water Pump
  • Type: Operation & user’s manual, PDF
  • Key Aspects: Pre-Installation Safety Requirements, End-of-Life Handling and Disposal, Advanced Configuration Methods
  • UPD Date: 31.05.2026
  • Source File: 2162321.pdf
  • Pages: 2
  • Description: User handbook for the Moog PainSmart IOD.
Pages Preview:
  • Moog PainSmart IOD Operation & user’s manual preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
KEYPAD FUNCTION ON/OFF: Turns pump on and off. When the pump is running, the PAUSE key must be used to stop infusion first. Then press the OFF key to turn pump off. RUN/PAUSE: Starts or pauses the pump. When the pump is paused, pressing this key will resume pumping. UP ARROW/ DOWN ARROW: Used to scroll through the display screens. NO/CHANGE: Rejects highlighted data. YES/ ENTER: Accepts highlighted data. HELP/OPTIONS: Used to request and exit help screen when pump is paused, or go to options screen when pump is running. ./SILENCE: Used to silence alarm for 1 minute intervals, and as a decimal point. PRIME/BOLUS: Used to prime fluid through the tubing to clear it of air. Also used to provide a bolus dose when pump is running. LED INDICATORS Green- pump is running Yellow- standby Red- pump in alarm status MOOG MEDICAL DEVICES GROUP PainSmart IOD™ V2.01 Ambulatory Infusion Pumps Clinician’s Guide PCA THERAPY REFER TO USER’S MANUAL FOR DETAILED INSTRUCTIONS OPTIONS 1 LOCK: Press NO to change Lock Setting (may need access code). Press YES to accept new setting. 2 Clin DOSE: Press NO to OFF, YES to ON and enter the Clinician Dose as ordered. 3 SHIFT TOTAL: Press NO to OFF and YES to ON. To clear shift totals, press NO to Exit, YES to Clear, then YES to Exit. 4 HOURLY TOTAL: Press NO then YES to view. Scroll to review each hour’s totals. Press NO to exit. (BG is # of Boluses Given. BA is # of Boluses Attempted.) 5 CLEAR HOURLY: Press NO then YES to view. Press YES to clear, NO to retain and exit. 6 DOWN OCCLUSION: Press NO to change, YES to accept. 7 AIR SENSITIVITY: Press NO to change, YES to accept. 8 AUDIO: Press 1-9 to hear level, press YES to accept. 9 POWER CHECK: Press NO then YES to check level. 10 ACCEPT OPT? Press YES to accept any changes made. HOW TO CHANGE THE LOCK SETTING 1 Lock may be initially selected in BIOMED SETUP. 2 When infusing, press OPTIONS key. 3 Scroll to LOCK and press NO to change. 4 Enter access code at prompt. 5 Select NO until the desired lock setting is obtained. 6 Press YES/ENTER to select. 7 Exit Options menu by pressing YES at “ACCEPT OPT?” field. INSTALLING BATTERIES 1 Turn pump OFF or connect to AC adapter. 2 Open the battery door on the back of pump. 3 Insert 2 new “C” size alkaline (Duracell ProCell) batteries bottom side first with both positive poles at the top of the battery compartment. 4 Slide the battery compartment door back into place. USING THE HELP FUNCTIONS 1 When programming, press the HELP key. While running, press PAUSE, then press HELP key. 2 When a HELP screen is displayed and there is more text to read that is not displayed on the screen, or icons will appear, scroll up and down the text using the ARROW keys. 3 When finished, press the HELP key again to exit the HELP screen. Moog Medical Devices Group tf 800.970.2337 4314 Zevex Park Lane ph 801.264.1001 Salt Lake City, Utah 84123 USA fx 801.264.1051 www.moog.com/medical Moog is a registered trademark of Moog, Inc. and its subsidiaries. All trademarks indicated herein are the property of Moog, Inc. and its subsidiaries. © 2011 Moog, Inc. All rights reserved. 46263 Rev. A LCD DISPLAY RESOLUTION INFUSION COMPLETE Press PAUSE, add another IV bag, select REPEAT Rx and confirm fields, or turn the pump off. ALARM AIR-IN-LINE Remove air from administration set and IV bag. (Disconnect set from patient’s access site prior to using prime function.) ALARM DOWN OCCLUSION Check administration set from the pump to patient’s access site for cause of occlusion. Correct obstruc- tion per protocol. Consider changing the pressure setting from Low to High. When occlusion is resolved, the alarm will stop and pumping will resume. ALARM UP OCCLUSION Check administration set from IV bag to pump for cause of occlusion. When ready to begin infusion, press PAUSE, select RESUME, and press RUN. ALARM HIGH UP PRESSURE Check for excessive pressure on IV bag. When ready to begin infusion, press PAUSE, select RESUME, and press RUN. ALARM SET NOT INSTALLED Install appropriate Curlin Medical administration set. Use ONLY Curlin Medical administration sets. See User’s Manual or IV set directions for proper installation instructions. ALARM UNATTENDED PUMP To resolve, press RUN and resume the therapy or continue with operating procedure. ALARM REPLACE SET 3 Replace set, prime set if necessary, select RESUME and press RUN when ready to begin. ALARM DOOR OPEN Check placement of administration set and close pump door properly. See User’s Manual for instructions. ALARM EMPTY BATTERY Press the pause key and turn pump off. Install 2 new “C” size alkaline batteries. ERROR CODE If an error code occurs, turn pump off and consult provider or manufacturer. PUMP ALARMS & RESOLUTIONS

Similar Manuals in the Water Pump Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Dynaset 60

Dynaset 60 Guide (Installation manual), @KC2BSJ

16 1196 240 23-03-2026 view all manuals
Vogel Pumpen MASTER 2

MASTER 2 Use and maintenance instruction manual - F67657

80 1383 346 05-08-2026 view all manuals
Xylem Goulds NPE

User Manual: Xylem Goulds NPE (6YK938, Upd.28-04-2026)

24 1489 239 28-04-2026 view all manuals
STA-RITE MPRA6D-146L

PDF User Manual (@4GC967), STA-RITE MPRA6D-146L Water Pump (15-06-2026)

16 54 10 15-06-2026 view all manuals
Bolttech-Mannings TP30K-Z-DP

TP30K-Z-DP (Water Pump ePDF Guide, #2W35OL)

13 194 33 12-08-2026 view all manuals
Doka CFT 700bar

Doka CFT 700bar Manual (Original operating instructions), @L9D1R7

16 1052 211 03-05-2026 view all manuals