Mosmatic FL-PH 520 Manuals

2 pdf manual(s) Mosmatic FL-PH 520 for free download (Document Types: Assembly instructions, Quick start manual)

Document Preview & Text Transcription

TD - 80774 A © MOSMATIC AG 05.12.2007 Subject to change without notice FL-PH 520 No. 80.774 Assembly instructions For your own safety - Read all instructions before the initial operation. Check their proper condition and that they operate safely. - Always use protective gear when using products connected to high pressure. - Before any maintenance or nozzle-change, turn off the high pressure water supply, e.g.: turn off and secure the power switch. - After turning off the system, allow all self propelled equipment to come to a complete stop before handling. - Safety regulations and guidelines (Accident Prevention Rules) from the manufacturer of your high pressure cleaner are applicable. - Nozzle installation according to nozzle manufacturer. - Do not move the unit over objects or uneven surfaces. - Do not lift up the unit while operating. - Do not run the unit if spray-arm is out of balance or bent, damage to the swivel will result. - No modifications to the unit are permitted. 1. Slide the upper fork (a) over the lower fork (b). Secure the two forks with the bolt (c) and the safety nut (d). Note: the handle (e) and the ring (f) point in the same direction. 2. Connect the HP-gun (g) with the preinstalled adapter (h) to the quick connect (i). 3. Install the assembled fork (a+b) with the two bolts (k) and the two safety nuts (l) onto the fork holder (j). Works best if handle is in vertical position. 4. Connect the HP hose (m) with the quick connect (n) to the swivel (o). 5. Install the wand holder (p) by using the pipe clamp (q) onto the lower fork (b). Note: Adjust the bolts (r) of the wheel suspension (s) up or down for the ideal cleaning distance with the provided hexagon socket wrench (t). Professional Surface Cleaner ( This instruction is valid for the base model as well as for the resulting versions) p q r s t g e h i a c d m o n b l j k f FL-PH 520 No. 80.774 TD - 80774 A © MOSMATIC AG 05.12.2007 Subject to change without notice Professional Surface Cleaner Spare parts List 16 10 9 8 3 11 12 13 14 2 1 15 17 4 5 6 7 Pos. Part No. Description 1 55.253 Swivel DYC 2 36.906 Carbide seal-kit 3 50.155 Quick-connect M22-F - G1/4"F 4 902.113 Pipe clamp 5 902.116 Wand holder Dia. 2¼" x 22" 6 26.994 HP-wand 7 1506 HP-nozzle 1506 8 51.278 Adapter M22-M - 1/4"NPT-M 9 29.081 HP-gun 4000 psi 10 50.903 Quick-connect M22-F - G1/4"M 11 901.953 HP-hose G1/4"M - G1/4"M 12 902.647 Support 13 80.956 Stainless steel castor 14 900.436 Brush ring 15 82.942 Turbo-rotor-arm Dia. 18,5" 16 1503 HP-nozzle 1503 17 901.950 Hexagon socket wrench 6mm

Document Preview & Text Transcription

TD - 80754 D/E © MOSMAT A IC AG 30.09.2011 Änderungen vorbehalten / Subjb ect to change wi w th t out notice FL-PH 520 No. 80.754 Montageanleitung Flächenreiniger Professional Professional Surface Cleaner 1. Slide the upper fork (a) over the lower fork (b). Secure the two forks with the bolt (c) and the safety nut (d). Note: the handle (e) and the ring (f) point in the same direction. 2. Connect the HP-gun (g) with the preinstalled adaptor (h) to the quick connect (i). 3. Install the assembled fork (a+b) with the two bolts (k) and the two safety nuts (l) onto the fork holder (j). Works best if handle is in vertical position. 4. Connect the HP hose (m) with the quick connect (n) to the swivel (o). 5. Install the wand holder (p) by using the pipe clamp (q) onto the lower fork (b). Note: Adjust the bolts (r) of the wheel suspension (s) up or down for the ideal cleaning distance with the provided hexagon socket wrench (t). For your own safety - Read all instructions before the initial operation. Check their proper condition and that they operate safely. - Always use protection gear when using products connected to high pressure. - Before any maintenance or nozzle-change, turn off the high pressure water supply, e.g.: turn off and secure the power switch. - After turning off the system, allow all self propelled equipment to come to a complete stop before handling. - Safety regulations and guidelines (Accident Prevention Rules) from the manufacturer of your high pressure cleaner are applicable. - Nozzle installation according to nozzle manufacturer. - Do not move the unit over objects or uneven surfaces. - Do not lift up the unit while operating. - Do not run the unit if spray-arm is out of balance or bent, damage to the swivel will result. - No modifications to the unit are permitted. - The equipment may be installed and used only by particularly trained technical personnel. 1. Die obere Gabel (a) auf die untere Gabel (b) stecken, mit der Schraube (c) und der Sicherungsmutter (d) fixieren. Hinweis: Handgriff (e) und Ring (f) müssen in die gleiche Richtung zeigen! 2. Die HD-Pistole (g) mittels der vormontierten Verschraubung (h) an die Quick-Verschraubung (i) anschliessen. 3. Die zusammengebaute Gabel (a+b) senkrecht in die Schlitze der Gabelhalter (j) einführen und mit den Schrauben (k) und den Sicherheitsmuttern (l) befestigen. 4. Den HD-Schlauch (m) mit der Verschraubung (n) am Drehgelenk (o) anschliessen. 5. Das Lanzen-Aufnahmerohr (p) mit der Rohrbride (q) an die untere Gabel (b) befestigen. Hinweis: Durch Drehen der Einstellschrauben (r) an der Radaufhän- gung (s) mit einem Sechskant-Stiftschlüssel (t), lässt sich ein optimaler Reinigungsabstand einstellen. Für Ihre Sicherheit - Alle Anleitungen sind vor erster Inbetriebnahme zu lesen. Das Gerät ist auf ordnungsgemässen Zustand und Betriebssicherheit zu prüfen. - Alle Produkte die mit Hochdruck betrieben werden, dürfen nicht ungeschützt verwendet werden. - Bei Düsenwechsel sowie vor Wartungs- und Instandsetzungsarbeiten die Wasserzufuhr absperren, das System abschalten und gegen unbeabsichtigtes Einschalten sichern - Nach dem Abschalten des Systems läuft der Kreiselarm für kurze Zeit nach. Beim Anfassen des Kreiselarmes besteht Verletzungsgefahr. - Es gelten die Sicherheitsrichtlinien (Unfallverhütungsvorschriften) des Herstellers von Hochdruckgeräten. - Die Düsenbefestigung erfolgt laut Angaben des Düsen-Herstellers. - Das Gerät nicht über Gegenstände oder unebene Flächen führen. - Das Gerät während der Benutzung nicht anheben. - Bei einer Unwucht oder Krümmung des Kreiselarmes darf das Gerät nicht benutzt werden, da dadurch das Drehgelenk beschädigt wird. - An den Geräten dürfen keine Veränderungen vorgenommen werden. - Das Gerät darf nur von speziell ausgebildetem Fachpersonal installiert und bedient werden. Ass s embly l in i str t u r ctit ons i ( Diese Anleitung gilt für das Basismodel sowie für daraus entstehende Versionen) ( This instruction is valid for the base model as well as for the resulting versions) p q r s t g e h i a c d m o n b l j k f FL-PH 520 No. 80.754 - 80754 D/E © MOSMAT A IC AG 30.09.2011 Änderungen vorbehalten / Subjb ect to change wi w th t out notice Flächenreiniger Professional Professional Surface Cleaner Ersatzteilliste Spare parts List Pos. Art. Nr. Bezeichnung 1 55.253 Drehgelenk DYC 2 36.905 Hartmetall-Dichtsatz 3 50.155 Quick-Verschraubung M22-F - G1/4"F 4 902.113 Rohrbride 5 902.116 Lanzen-Aufnahmerohr ø60 x 560 6 26.994 HD-Lanze 7 18.15060 HD-Düse 1506 8 51.275 Verschraubung M22-M - G1/4"M 9 29.053 HD-Pistole 250 bar 10 50.903 Quick-Verschraubung M22-F - G1/4"M 11 901.953 Schlauch G1/4"M - G1/4"M 12 902.647 Gabelstütze 13 80.956 INOX-Lenkrolle 14 900.436 Bürstenring 15 82.942 Turbo-Kreisel-Arm ø470 16 18.15030 HD-Düse 1503 17 901.950 Sechskant-Stiftschlüssel 6mm Pos. Part No. Description 1 55.253 Swivel DYC 2 36.905 Carbide seal-kit 3 50.155 Quick-connect M22-F - G1/4"F 4 902.113 Pipe clamp 5 902.116 Lance holder ø60 x 560 6 26.994 HP-lance 7 18.15060 HP-nozzle 1506 8 51.275 Adaptor M22-M - G1/4"M 9 29.053 HP-gun 250 bar 10 50.903 Quick-connect M22-F - G1/4"M 11 901.953 HP-hose G1/4"M - G1/4"M 12 902.647 Support 13 80.956 Stainless steel castor 14 900.436 Brush ring 15 82.942 Turbo-rotor-arm ø470 16 18.15030 HP-nozzle 1503 17 901.950 Hexagon socket wrench 6mm 16 10 9 8 3 11 12 13 14 2 1 15 17 4 5 6 7