Moxa Technologies SDR-480P Series Manuals
1 pdf manual(s) Moxa Technologies SDR-480P Series for free download (Document Types: Hardware installation manual)
Moxa Technologies SDR-480P Series Hardware installation manual [PDF] (2 pages)
- Identifier: id-2429268
- Brand: Moxa Technologies
- Device: SDR-480P Series Power Supply
- Type: PDF
- Key Aspects: Error Code Explanations, Component Overview and Descriptions, Recommended Spare Parts List
- UPD Date: 10.09.2026
- Source File: 2375471.pdf
- Pages: 2
- Description: Quick reference guide for the Moxa Technologies SDR-480P Series.
Click to expand and read text
– 1 – – 2 – – 3 – SDR-480P Series Hardware Installation Guide First Edition, July 2015 Dimensions Terminal Pin No. Assignments (TB1) PIN No. Assignment 1 FG 2 AC/N 3 AC/L Terminal Pin No. Assignments (TB2) PIN No. Assignment 1, 2 DC Output V+ 3, 4 DC Output V- 5, 6 Relay Contact 7 P+ (Current share) 8 P- (Current share) Mounting Instructions Mounting: Mount only as shown in figure, with input terminals facing downwards to allow sufficient cooling. Admissible DIN rails: TS35/7.5 or TS35/15. To attach the SDR-480P to the rail: 1. Rotate the SDR-480P backwards, as shown in the figure. 2. Fit the top of the SDR-480P over the top hat rail. 3. Slide the SDR-480P downwards until it hits the stop. 4. Push the bottom of the SDR-480P forward until it snaps into place. 5. Move the SDR-480P back and forth to make sure it is locked in place. Installation 1. To prevent the unit from overheating, always allow sufficient clearance around the unit for proper ventilation: 5 mm left and right, 40 mm above, and 20 mm below. You should also keep a 10 to 15 cm clearance from adjacent devices that act as a heat source. 2. The appropriate mounting orientation is vertical, with input terminals on the bottom and output on the top of the SDR-480P. Other mounting orientations, such as upside down, horizontal, or table-top, are not allowed. 3. Use copper wire only; the recommended wiring is shown below. AWG 18 16 14 12 10 Rated Current (Amps) 6 6-10 13-16 16-25 25-32 Lead cross-section (mm2) 0.75 1.00 1.5 2.5 4 Note: When 5 or more wires are connected to the unit, the current carried by each wire could be 20% less than the current listed above. Make sure that all strands of each wire are properly inserted into the terminal connection, and that the screw terminals are securely fixed to prevent poor contact. If the power supply has multiple output terminals, make sure each contact is connected to wires to prevent stress on a single contact from too much current. 4. Use wire that can withstand temperatures of at least 80°C, such as UL1007. 5. Suggested fuses and the maximum number of the PSUs that can be connected to a circuit breaker at 230 V are shown as below: Model Fuse Circuit breakers C16 D16 SDR-480P T8A/L250V 4 4 6. The recommended wire strapping length is 5 mm (0.197 inch). 7. Use a slotted type 4 mm screwdriver. 8. Use the following torque settings for terminals: Model I/P O/P SDR-480P 5 kgf-cm (4.4 in-lb) 8 kgf-cm (7 in-lb)
Moxa Technologies SDR-480P Series: Power Supply Category Related Instructions
Complete instruction guide for the Friedman Power Grid 10 Power Supply. It describes step-by-step system parameters, operating instructions, maintenance schedule, firmware installation.
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: [email protected] Model #: P056-006 6 ft. Power cord (IEC-320-C13 to BS-1363 UK Plug) Highlights C13 to BS1363 UK Power Cable, 6ft HO5VV-F3G 1.0mm² Wire 5A Fuse De User guidebook for the Tripp Lite P056-006 Power Supply. It covers repair references, performance optimization, application scenarios, technical guidelines.
U P S Uninterruptible Power System Line Interactive Network UPS 800VA/1000VA 1200VA/1500VA/2200VA USER‘S MANUAL Printed in USA ABC Owner’s manual for the Powercom 800VA Power Supply. It describes step-by-step usage procedures, interface navigation, regulatory notices.
10000056045 00 G. FILLUS 07-16-09 1 4 B TECHNICAL DATA SHEET BUL. 1606-XLE120E-2 AND 1606-XLE240E-3 POWER SUPPLIES 1 EN Instruction Manual DC Power Supply 2 DE Bedienungsanleitung DC Stromversorgung 3 FR Manual d'instructions Full operation manual for the Rockwell Automation 1606-XLE96B-2 Power Supply. This manual covers hardware instructions, maintenance guidelines, replacement parts, operational guidelines.