MULTI MEASURING INSTRUMENTS 230+ Manuals

1 pdf manual(s) MULTI MEASURING INSTRUMENTS 230+ for free download (Document Types: Instruction manual)

Document Preview & Text Transcription

Thank you very much for selecting our digital AC/DC current clamp-on tester. This model is complex instrument and employ a very reliable mechanical/electronic design. Before you use your new instrument, read this Instruction Manual completely and familiarize yourself thoroughly with all functions. With proper use and care, your tester will give you years of satisfactory service. 1. FEATURES ● Useful for DCA measurement for automobile service. ● Accurate gearing mechanism for closing of CT. ● Data hold function. Especially useful when working in dark or hard to get areas. ● Ultra compact size. 2. SPECIFICATION Measuring method Dual integration mode Display 3.5 digit LCD Range AC/DC 20A/200A (AC 50/60Hz) Ranging Manual ranging Accuracy AC 50/60Hz or DC, 23℃±5℃, 80% RH max. Range Mini. Resolution Accuracy AC 20A (50/60Hz) 10mA ±1.0%rdg ±5dgt AC 200A (50/60Hz) 100mA ±1.5%rdg±5dgt(0~150A ) ±2.5%rdg±5dgt(150A~200A ) DC 20A 10mA ±1.0%rdg ±5dgt DC 200A 100mA ±1.5%rdg±3dgt(0~150A) ±2.5%rdg±3dgt(150~200A) AC/DC CURRENT MINI DIGITAL CLAMP-ON TESTER MODEL 230+ INSTRUCTION MANUAL Jaw opening capability 23mmφ Over range indication “O.L” mark on LCD readout Auto power-off function Approx. 10 minutes later, after the power-on. To power-on again, at first, “off” the power-switch. Wait about 5 seconds and switching to “on” again. Maximum indication 1999 count Low battery indication "B" mark on LCD readout Data hold indication "D・H" mark on LCD readout Sampling time Approx. 2 times/sec. Limitation of circuit voltage Less than AC/DC 600V Withstanding voltage AC 1000V/1 minute between CT core and outer case Insulation resistance 10MΩ or more between internal circuit and CT core. Operating temperature 0℃ to +40℃, <80%RH (non-condensing) Storage temperature -10℃ to +60℃, <70% RH (non-condensing) Power supply LR-44(1.5V)x2 or SR-44x2 Power consumption Approx. 7mW Battery life Approx. 16 hours (LR-44) Approx. 30 hours (SR-44) Size 48(W)x146(H)x20(D)mm Weight Approx. 100g Accessories Batteries (LR-44)………….2 Instruction manual……..…1 Soft case……………….…….1 3. CAUTION ● Before operating this instrument, familiarize yourself with all instructions outlined in this manual. ● Always check to make sure that the function switch is set to the proper position. ● When making measurements, use CAUTION as dangerous voltages may be present in normally safe areas. ● To avoid electrical shock, use CAUTION when working above 60V DC or 25V AC rms. Such voltages pose a shock hazard. ● Never make measurements with the battery cover OFF. ● Never fail to keep the maximum tolerable input. ● Never operate this instrument if it becomes wet, damp or has any liquid condensation build-up on any part of the instrument. ● Never make measurements for uninsulated conductors or bus bars. 4. DIMENSIONS AND PANEL FUNCTION ① ⑨ ⑧ Fig. 1 ①Current transducer(Jaw) ⑦Zero adjustment knob ②Jaw opening lever ⑧Battery cover ③Range switch ⑨AC/DC switch ④Data hold switch ⑩Power switch ⑤LCD display ⑥Wrist strap 5. METHOD OF MEASUREMENT ① Set the power switch to “ON” position. ② Set the AC/DC switch to AC or DC depending upon the signal to be measured. Note: In AC current measurement, even if “1” is displayed in the least digit without input, however, it is not abnormal and no influence for the measurement accuracy. ③ Set the range switch to the desired range. ④ Adjust the zero adjustment knob to read zero for DC current measurement. ⑤ Clamp the conductor of the circuit under test with current transducer. Note: Clamp around only one conductor in the circuit to be measured. ⑥ Read the displayed value. ⑦ After measurement, set the power switch to “OFF”. CAUTION: This tester is designed for low voltage applications. To avoid electrical shock or damage, the measurement is limited to the circuit under 600V AC.