mundoclima MUENR-H6 Series Manuals

2 pdf manual(s) mundoclima MUENR-H6 Series for free download (Document Types: Installation & owner's manual)

Available Documents for MUENR-H6 Series:

mundoclima MUENR-H6 Series Installation & owner's manual Main Page Preview

Installation & owner's manual [PDF] (54 pages)

  • Brand: mundoclima
  • Model: MUENR-H6 Series
  • Format: PDF
  • Key Aspects: Product Performance Metrics, Warranty and Service Information, Safety Recommendations and Warnings
  • Updated: 22.08.2026
  • Source File: 2377949.pdf
  • Pages: 54
  • Description: Practical operating guide for the mundoclima MUENR-H6 Series.

Document Preview & Text Transcription

MINI CHILLER INVERTER H6 English CL25620 to CL25628 MUENR-H6 / MUENR-H6T www.mundoclima.com Installation & Owner's manual and information requirements 1.2 Scope of this manual READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. IMPROPER INSTALLATION OR ATTACHMENT OF EQUIPMENT OR ACCESSORIES COULD RESULT IN ELECTRIC SHOCKS, SHORT-CIRCUITS, LEAKS, FIRE OR OTHER DAMAGE TO THE EQUIPMENT. BE SURE TO ONLY USE ACCESSORIES MADE BY THE SUPPLIER WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH THE EQUIPMENT AND HAVE INSTALLATION DONE BY A PROFESSIONAL ALL ACTIVITIES DESCRIBED IN THIS MANUAL SHALL BE CARRIED OUT BY A LICENSED TECHNICIAN. BE SURE TO WEAR ADEQUATE PERSONAL PROTECTION SUCH AS GLOVES AND SAFETY GLASSES WHEN PERFORMING INSTALLATION, MAINTENANCE OR SERVICE TO THE UNIT. IF UNSURE OF INSTALLATION PROCEDURES OR USE, CONTACT YOUR DEALER FOR GUIDANCE ■ Operation range (*) The unit can not operate in cold weather conditions below -15℃. If it is necessary to operate, an external auxiliary heat source must be added as a backup heater. the backup heater also serves as a backup in case of malfunctioning of the unit and for freeze ptrotection of the outside water piping during winter time. These models have an antifreeze function that allows the use of heat pumps to keep the water system free from freezing under all conditions. If there is an accident or intentional power outage, it is recommended to use ethylene glycol. 2. ACCESSORIES 2.1 Accessories supplied with the unit 1.1 General information ■ These units are used for both heating and cooling applications. They can be combined with fan coil units, floor heating applications (connect the mixed station), low temperature high efficiency radiators (field supply). ■ The host unit controller is standard supplied with the unit to control the system. ■ A wired remote controller can also be used to control the system (Optional). 1. INTRODUCTION CONTENTS PAGE 1. INTRODUCTION................................................................... 1 2. ACCESSORIES..................................................................... 1 3. SAFETY CONSIDERATIONS............................................... 2 4. OVERVIEW OF THE UNIT.................................................... 3 5. UNIT INSTALLATION........................................................... 11 6 START-UP AND CONFIGURATION.................................... 25 7. THE HOST UNIT CONTROLLER ELUCIDATION............... 27 8. TROUBLE SHOOTING......................................................... 31 9. IMPORTANT INFORMATION FOR THE USED REFRIGERANT..................................................................... 32 10. MAIN PARAMETERS......................................................... 33 HEATING MODE DELIVERY WATER TEMPERATURE OUTSIDE AIR TEMPERATURE 35 54 -15 0 27 t(°C) t(°C) 40 2 1 1 1 Shape Qty. Unit Outflow connecting tube (for the chassis) Straight screwdriver 1 Y-shaped filter Installation & Owner’s Manual Rubber ring for wires (only 10~16kW) COOLING MODE DELIVERY WATER TEMPERATURE OUTSIDE AIR TEMPERATURE 4 7 15 20 -5 35 46 t(°C) t(°C) This installation & owner's manual does not include the selection procedure and water system design procedure. Only some precautions and tips and tricks about the design of the water circuit are given in a separate chapter of this manual. Once the selection is done and the water system is designed, this manual describes the procedures for handing, installing and connecting the unit, This manual has been prepared to ensure adequate maintenance of the unit, and it will provide help if problems occur. This unit is designed to cool/heat water and must be used in applications compatible with its performance characteristics, i.e. residential or commercial applications combined with a fan coil unit, low temperature radiators and underfloor heating. It should never be used for underfloor cooling, as doing so may damage the plate heat exchanger. 1
mundoclima MUENR-H6 Series Installation & owner's manual Main Page Preview

Installation & owner's manual [PDF] (40 pages)

  • Brand: mundoclima
  • Model: MUENR-H6 Series
  • Format: PDF
  • Key Aspects: Device Specifications Overview, Performance Optimization Tips, Unpacking and Inspection Guidelines
  • Updated: 21.08.2026
  • Source File: 1974824.pdf
  • Pages: 40
  • Description: Operating handbook for the mundoclima MUENR-H6 Series.

Document Preview & Text Transcription

MINI CHILLER INVERTER H6 English CL25622 to CL25628 MUENR-H6 / MUENR-H6T (10, 12, 14, 16 kW) www.mundoclima.com Installation & Owner's manual and information requirements The following symbols are used in this publication and inside the unit: User Installer Assistance Important Prohibition Danger voltage Danger moving blades Danger high temperatures INDEX 70°C A I U General warnings 2 Fundamental safety rules 2 Description of standard unit 3 Dimensioned drawings 4 Installation 4 Hydraulic connections 6 Electrical connections 9 Operation limits 14 15 17 Checking and starting up the unit 18 Activating and deactivating the unit 18 Shutting down for long periods 23 Routine maintenance 23 Extraordinary maintenance 23 U I A U I A I A I I I A I A I A I A I A A U I A A A A Disposal 25 A Troubleshooting 25 I A 1 against freezing 14 I A Protection the water circuit 17 I A Hydraulic data Important information for the 28 U I A used refrigerant Information requirements 29 U I A Refrigerant circuit 17 I A of first installation Failure diagnosis at the moment Filling with water Operating characteristics 24 I A 27 I A Specifications GENERAL WARNINGS When operating equipment involving the use of electricity and water,a number of fundamental safety rules must be observed,namely: This appliance is not intended for use by persons (including children) with reduced physical,sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Do not touch the unit with bare feet or with wet or damp parts of the body Do not carry out cleaning operations without first disconnecting the system from the electricity supply. Do not modify safety or regulation devices without authorisation and instructions from the manufacturer. Do not pull,detach or twist the electrical cables coming from the unit,even when disconnected from the mains electricity supply. Do not open doors or panels providing access to the internal parts of the unit without first ensuring that the mains switch is in the off position. Do not introduce pointed objects through the air intake and outlet grills. Do not dispose of,abandon or leave within reach of children packaging materials (cardboard, staples, plastic bags, etc.) as they may represent a hazard. The chiller appliances are supplied without the main switch.The power supply to the unit must be disconnected using a suitable main switch that must be supplied and installed by the installer. Respect safety distances between the unit and other equipment or structures.Guarantee adequate space for access to the unit for maintenance and/or service operations; Power supply:the cross section of the electrical cables must be adequate for the power of the unit and the power supply voltage must correspond with the value indicated on the respective units.All units must be earthed in conformity with legislation in force in the country concerned. Hydraulic connections should be carried out as indicated in the instructions to guarantee correct operation of the unit.Empty the water circuit or add glycol if the unit is not used during the winter. Handle the unit with the utmost care to avoid damage. FUNDAMENTAL SAFETY RULES U A I U A I 2 This unit is designed to cool/heat water and must be Incorrect installation,regulation and maintenance or improper use absolve the manufacturer from all liability,whether contractual or otherwise,for damage to people,animals or things.Only those applications specifically indicated in this list are permitted. Read this manual carefully.All work must be carried out by qualified personnel in conformity with legislation in force in the country concerned. The guarantee is invalidated if the above instructions are not respected and if the unit is started up for the first time without the presence of personnel authorised by the Company (where specified in the supply contract) who should draw up a “start-up” report. The documentation supplied with the unit must be consigned to the owner who should keep it carefully for future consultation in the event of maintenance of service. All repair or maintenance work must be carried out bythe Company’s Technical Service or qualified personnel following the instructions in this manual. The air-conditioner must under no circumstances be modified or tampered with as this may create situations of risk.Failure to observe this condition absolves the manufacturer of all liability for resulting damage. used in applications compatible with its performance characteristics, i.e. residential or commercial applications combined with a fan coil unit, low temperature radiators and underfloor heating. It should never be used for underfloor cooling, as doing so may damage the plate heat exchanger.