Munters WF50 Series Manuals

2 pdf manual(s) Munters WF50 Series for free download (Document Types: Instruction manual)

Document Preview & Text Transcription

1 © Munters Corporation, December 2019 QM1075r3 Instruction Manual WF50 Galvanized Tilt Fan with Cone Partially Assembled, No Crate Models: WF501TxCP • WF501TxCY • WF5015TxCP • WF5015TxCY WF50-99 Galvanized 50” Tilt Fan with Cone Partially Assembled, No Crate © Munters Corporation, December 2019 2 QM1075r3 WF50 Galvanized Tilt Fan with Cone Instructions for Use and Maintenance Thank You: Thank you for purchasing a Munters WF50 Fan. Munters equipment is designed to be the highest performing, highest quality equipment you can buy. With the proper installation and maintenance it will provide many years of service. Please Note: To achieve maximum performance and insure long life from your Munters product it is essential that it be installed and maintained properly. Please read all instructions carefully before beginning installation. Warranty: For Warranty claims information see the “Warranty Claims and Return Policy” form QM1021 available from the Munters Corporation office at 1-800-227-2376 or by e-mail at [email protected]. Conditions and Limitations: • Products and Systems involved in a warranty claim under the “Warranty Claims and Return Policy” shall have been properly installed, maintained and operated under competent supervision, according to the instructions provided by Munters Corporation. • Malfunction or failure resulting from misuse, abuse, negligence, alteration, accident or lack of proper installation or maintenance shall not be considered a defect under the Warranty. 3 © Munters Corporation, December 2019 QM1075r3 Index Chapters Page 1. Unpacking the Equipment 4 1.1 Parts List 4 1.2 Fan Dimensions 5 2. Installation Instructions 6 2.1 Installation 6 3. Electrical Wiring 9 3.1 Wiring 9 3.2 Recommended Wire Routing 10 4. Operation 11 5. Maintenance 12-13 6. Winterizing 14 6.1 Winterizing 14 6.2 Winter Weather Protection 14 7. Troubleshooting 15 8. Exploded View and Parts List 16-17 © Munters Corporation, December 2019 4 QM1075r3 1.1 Parts List Unpacking the Equipment 1. [A] [B] [C] [D] [E] [F] [G] [H] [J] [K] Each Fan includes: 1 – 50” Belt Drive Fan 4 – Cone Sections 4 – Cone Support Brackets 1 – Cone Guard 1 – 3-Blade Propeller 1 – Shutter 1 – Hardware Package (HP1118): HP1118 – for WF50-99 Fans ID Qty. Cat. No. Description - - Hardware for Cone Installation - - [A] 12 KS1152 1⁄4”-20 x 1.75” SRTD Flange Head Bolt, ZP [B] 16 KS1153 1⁄4”-20 x ¹⁄₂” SRTD Flange Head Bolt, ZP [C] 28 KN0730 1⁄4”-20 SRTD Flange Nut, ZP [D] 8 KS2260 1⁄4”-20 x ³⁄₄” SRTDHXWSHR TEK Screw, ZP [E] 12 KX1256 .32"IDx.75"ODx1"L. Spacer, Black, NY - - Hardware for Fan Installation - - [F] 12 KS2463 1⁄4” x 1.5” Hex Lag Screw, ZP [G] 12 KS2203 1⁄4”-20 x ¹⁄₂” SRTDHXWSHR Type-F Screw, ZP [H] 4 KS1928 M8-1.25 x 25mm Hex Bolt, ZP [J] 4 KW4906 M8 Star Lock Washer, BLK [K] 4 KN1849 M8-1.25 x 8mm Hex Nut, ZP [L] 2 - - - Yellow Vertical Warning Labels Before beginning installation, check the overall condition of the equipment. Remove packing materials, and examine all components for signs of shipping damage. Any shipping damage is the customer’s responsibility and should be reported immediately to your freight carrier. Fan is shipped complete with all accessories.

Document Preview & Text Transcription

1 © Munters Corporation, December 2019 QM1079r12 Instruction Manual WF50 Fan with Dragonfly Damper Door Models: WF501VxCD • WF5015VxCD WF50 Fan with Dragonfly Damper Door Galvanized © Munters Corporation, December 2019 2 QM1079r12 WF50 Fan with Dragonfly Damper Door Instructions for Use and Maintenance Thank You: Thank you for purchasing a Munters WF50 Dragonfly Fan. Munters equipment is designed to be the highest performing, highest quality equipment you can buy. With the proper installation and maintenance it will provide many years of service. Please Note: To achieve maximum performance and insure long life from your Munters product it is essential that it be installed and maintained properly. Please read all instructions carefully before beginning installation. Warranty: For Warranty claims information see the “Warranty Claims and Return Policy” form QM1021 available from the Munters Corporation office at 1-800-227-2376 or by e-mail at [email protected]. Conditions and Limitations: • Products and Systems involved in a warranty claim under the “Warranty Claims and Return Policy” shall have been properly installed, maintained and operated under competent supervision, according to the instructions provided by Munters Corporation. • Malfunction or failure resulting from misuse, abuse, negligence, alteration, accident or lack of proper installation or maintenance shall not be considered a defect under the Warranty. 3 © Munters Corporation, December 2019 QM1079r12 Index Chapters Page 1. Unpacking the Equipment 4 1.1 Parts List 4 1.2 Fan Dimensions 5 2. Installation Instructions 6 2.1 Installation 6 3. Electrical Wiring 8 3.1 Wiring 8 3.2 Recommended Wire Routing 9 4. Operation 10 5. Maintenance 11-12 6. Winterizing 13 6.1 Winterizing 13 6.2 Winter Weather Protection 13 7. Troubleshooting 14 8. Exploded View and Parts List 16-17