National Instruments PXI-1042HVDC Manuals

1 pdf manual(s) National Instruments PXI-1042HVDC for free download (Document Types: Installation manual)

National Instruments PXI-1042HVDC Installation manual Thumbnail

National Instruments PXI-1042HVDC Installation manual [PDF] (2 pages)

  • Identifier: id-2155749
  • Brand: National Instruments
  • Device: National Instruments PXI-1042HVDC Cables and connectors
  • Type: Installation manual, PDF
  • Key Aspects: Environmental Factors and Restrictions, Risk Mitigation and Accident Prevention, Additional Modules and Accessories Guide
  • UPD Date: 23.03.2026
  • Source File: 2131886.pdf
  • Pages: 2
  • Description: User guide for the National Instruments PXI-1042HVDC.
Pages Preview:
  • National Instruments PXI-1042HVDC Installation manual preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
INSTALLATION GUIDE NI PXI-1042HVDC DC Cable Kit The PXI-1042HVDC DC cable is designed to connect the PXI-1042HVDC chassis to a DC power source. The cable consists of a DC power connector, 18 feet of 10 AWG cable, and a high heat, impact resistant, water tight fuse holder with a 20 A fuse installed. For maximum DC power source protection, the fuse is located as close to the DC power source as is practical. The user must install the appropriate connectors required to connect the cable to their DC power source. Caution Observe proper polarity when connecting to a DC power source. Refer to drawing CD_192057-01 for more detail. Fuse Replacement Caution Disconnect the cable from the PXI-1042HVDC chassis and any power source before replacing the fuse or connecting the fuse holder to the DC cable. Complete the following steps to replace the fuse: 1. Unscrew the two halves of the fuse holder body by turning one half in a counter-clockwise direction. 2. Replace the fuse with an F20A, 500 VDC/600 VAC, 1.5 in. × .41 in. (10 mm × 38 mm) Midget, fast-acting fuse. 3. Align the mating tabs on one half of the fuse holder body with the slots on the other half, and screw the two halves back together in a clockwise direction. Hand tighten only. Reducing Cable Length National Instruments recommends using the cable at its designed length. If it is necessary to shorten the cable for a particular application, the following guidelines should be observed. Caution Do not leave the fuse holder out of the cable assembly.

Similar Manuals in the Cables and connectors Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Alpine KWE-901G7MIC

Cables and connectors #Q8461F

2 465 80 13-06-2026 view all manuals
Mitsubishi Electric MAC-1702RA-U

MAC-1702RA-U (Cables and connectors ePDF User Guide, #T22345)

2 120 28 14-07-2026 view all manuals
Street Guardian SGDCHW

Street Guardian Cables and connectors Operation & user’s manual (File: PDF, 15-04-2026)

12 1206 218 15-04-2026 view all manuals
CYP CDPS-UA1H4HS

Cables and connectors #19AGFY

12 509 97 30-04-2026 view all manuals
Meteor Atria 10

Meteor Atria 10 User Guide (Manual ), @A3P185

5 946 218 27-05-2026 view all manuals
National Instruments 9923

National Instruments 9923 User Guide (User manual and specifications), @65V953

8 917 221 30-06-2026 view all manuals