Neptronic EFCB10TU2 Manuals

2 pdf manual(s) Neptronic EFCB10TU2 for free download (Document Types: Specification and installation instructions)

Neptronic EFCB10TU2 Specification and installation instructions Thumbnail

Neptronic EFCB10TU2 Specification and installation instructions [PDF] (16 pages)

  • Identifier: id-1250967
  • Brand: Neptronic
  • Device: Neptronic EFCB10TU2 Thermostat
  • Type: Specification and installation instructions, PDF
  • Key Aspects: Regulatory Compliance and Standards, End-of-Life Handling and Disposal, Troubleshooting Information
  • UPD Date: 09.03.2026
  • Source File: 907302.pdf
  • Pages: 16
  • Description: Device maintenance guide for the Neptronic EFCB10TU2.
Pages Preview:
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 2
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 3
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 4
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 5
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 6
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 7
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 8
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 9
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Networkable Fan Coil Controller Specification and Installation Instructions EFCB-TFL5-180323-ESA Page | 1 EFCB Series EFCB10TU2 (24Vac / 2 relays) EFCB10TU4 (24Vac / 4 relays) EFCB11TU2 (120Vac / 2 relays) EFCB11TU4 (120Vac / 4 relays) EFCB12TU2 (240Vac / 2 relays) EFCB12TU4 (240Vac / 4 relays) TFL54 (Thermostat) TFLH54 (Thermostat with humidity) EFCB Series TFL54 or TFLH54 Description The EFCB Series Networkable Fan Coil Controller and TFL Series LCD Thermostat are designed for simple and accurate control of any fan coil application. The Networkable Fan Coil Controller is mounted inside the fan coil cabinet and incorporates a configurable fan coil algorithm, variable three speed fan control and either modulating or digital heating and cooling outputs. All inputs and high/low voltage outputs are centralized at the control module in the fan coil cabinet. Applications  Compatible with 2 or 4 pipe systems  Fan coil unit (up to 3 speeds and/or analog 0-10 Vdc)  Cooling signal (on/off, floating or modulating 0-10 Vdc)  Heating signal (on/off, floating, pulse or modulating 0-10 Vdc)  Cool, Heat, Reheat, Reheat with fan, Changeover, Fan, Humidify and Dehumidify by cooling. Typical Application Features  Built-in configurable fan coil algorithms  Up to 10 inputs and 15 outputs (configurable)  Select direction on digital inputs and all outputs  Selectable proportional control band and dead band  Selectable fan speed contacts  Independent cool/heat setpoint for NSB/OCC mode  No occupancy and NSB override  Selectable internal or external temperature sensor (10KΩ)  Change over by contact or 10KΩ temperature sensor  Internal and external temperature sensor calibration  Freeze protection  Multi level lockable access menu and setpoint  Removable, raising clamp, non-strip terminals Thermostat Features  Backlit LCD with simple icon and text driven menus  Select thermostat’s default display  BACnet service port via on-board mini USB connector  Selectable Fahrenheit or Celsius scale  3-wire connection to controller and 4 push buttons Network Communication  BACnet® MS/TP or Modbus communication port  Select MAC address via DIP switch or via network  Automatic baud rate detection BACnet MS/TP®  Automatic device instance configuration  Copy & broadcast configuration via thermostat menu or via BACnet to other controllers  BACnet scheduler  Firmware upgradeable via BACnet  Support COV (change of value) Modbus  Modbus @ 9600, 19200, 38400 or 57600 bps  RTU Slave, 8 bits (configurable parity and stop bits)  Connects to any Modbus master
Neptronic EFCB10TU2 Specification and installation instructions Thumbnail

Neptronic EFCB10TU2 Specification and installation instructions [PDF] (24 pages)

  • Identifier: id-1687256
  • Brand: Neptronic
  • Device: Neptronic EFCB10TU2 Control Unit
  • Type: Specification and installation instructions, PDF
  • Key Aspects: Efficiency and Calibration Tips, Best Practices for Everyday Use, Safety Recommendations and Warnings
  • UPD Date: 05.08.2026
  • Source File: 1631469.pdf
  • Pages: 24
  • Description: Detailed user guide for the Neptronic EFCB10TU2.
Pages Preview:
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 2
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 3
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 4
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 5
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 6
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 7
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 8
  • Neptronic EFCB10TU2 Specification and installation instructions preview - page 9
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Networkable Fan Coil Controller Specification and Installation Instructions EFCB1xTUx-TFL2-TDF-191018-ESA Page | 1 Models EFCB10TU2 (24Vac / 2 relays) EFCB10TU4 (24Vac / 4 relays) EFCB11TU2 (120Vac / 2 relays) EFCB11TU4 (120Vac / 4 relays) EFCB12TU2 (240Vac / 2 relays) EFCB12TU4 (240Vac / 4 relays) TFL24 Series Digital Room Sensor TFL24 (With temperature sensor) TFLH24 (With temperature and humidity sensor) TFLG24 (With temperature and CO2 sensor) TFLGH24 (With temperature, CO2 and humidity sensors) TDF Series Digital Room Sensor TDF00 (Vertical Grey LCD, white enclosure) TDF30 (Vertical Black LCD, black enclosure) TDF60 (Vertical Black LCD, white enclosure) TDF10 (Horizontal Grey LCD, white enclosure) TDF40 (Horizontal Black LCD, black enclosure) TDF70 (Horizontal Black LCD, white enclosure) EFCB Series TFL24 Series TDF00 / TDF30 / TDF60 Series TDF10 / TDF40 / TDF70 Series Description The EFCB Series Networkable Fan Coil Controller, and TFL24 and TDF Series Digital Room Sensors are designed for simple and accurate control of any fan coil application. The BACnet Fan Coil Controller is mounted inside the fan coil cabinet and incorporates a configurable fan coil algorithm, variable three speed fan control and either modulating or digital heating and cooling outputs. All inputs and high/low voltage outputs are centralized at the control module in the fan coil cabinet. Applications • Compatible with 2 or 4 pipe systems • Fan coil unit (up to 3 speeds and/or analog 0-10 Vdc) • Cooling signal (on/off, floating or modulating 0-10 Vdc) • Heating signal (on/off, floating, pulse or modulating 0-10 Vdc) • Cool, Heat, Reheat, Reheat with fan, Changeover, Fan, Humidify and Dehumidify by cooling. Features • Built-in configurable fan coil algorithms • Up to 10 inputs and 15 outputs (configurable) • Select direction on digital inputs and all outputs • Selectable proportional control band and dead band • Selectable fan speed contacts • Independent cool/heat setpoint for NSB/OCC mode • No occupancy and NSB override • Selectable internal or external temperature sensor (10KΩ) • Change over by contact or 10KΩ temperature sensor • Internal and external temperature sensor calibration • Freeze protection • Multi level lockable access menu and setpoint • Removable, raising clamp, non-strip terminals Digital Room Sensor Features • Backlit LCD with simple icon and text driven menus • Select digital room sensor’s default display • BACnet service port via on-board mini USB connector • Selectable Fahrenheit or Celsius scale • 3-wire connection to controller and 4 push buttons Network Communication • BACnet® MS/TP or Modbus communication port • Select MAC address via DIP switch or via network • Automatic baud rate detection BACnet MS/TP® • Automatic device instance configuration • Copy and broadcast configuration via digital room sensor menu or via BACnet to other controllers • BACnet scheduler • Firmware upgradeable via BACnet • Support COV (change of value) Modbus • Modbus @ 9600, 19200, 38400 or 57600 bps • RTU Slave, 8 bits (configurable parity and stop bits) • Connects to any Modbus master

Similar Manuals in the Control Unit, Thermostat Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Vestamatic VestaLogo 500

Control Unit #JA3PAD

18 441 102 25-04-2026 view all manuals
Siemens SIRIUS 3RK3

Security Sensors #BNPRJY

318 933 187 24-07-2026 view all manuals
Polycom VVX 410 Series

Polycom VVX 410 Series Manual (Quick start manual), @U8R25E

6 1188 262 10-03-2026 view all manuals
Franke F3EV1001

PDF User Manual (@418U87), Franke F3EV1001 Plumbing Product (03-03-2026)

44 320 52 03-03-2026 view all manuals
Z-World RabbitCore RCM2100 Series

Z-World Control Unit Getting started manual (File: PDF, 18-05-2026)

56 864 199 18-05-2026 view all manuals
ProSoft Technology inRAx MVI46-DFNT

PDF Manual (@BZA43C), ProSoft Technology inRAx MVI46-DFNT Control Unit (06-07-2026)

118 24 6 06-07-2026 view all manuals