Nero Radio 8117 micro Manuals
1 pdf manual(s) Nero Radio 8117 micro for free download (Document Types: Quick start manual)
Nero Radio 8117 micro Quick start manual [PDF] (2 pages)
- Identifier: id-1959416
- Brand: Nero
- Device: Nero Radio 8117 micro Control Unit
- Type: Quick start manual, PDF
- Key Aspects: Pre-Deployment Preparation Steps, Package Contents and Accessories List, Pre-Installation Safety Requirements
- UPD Date: 06.06.2026
- Source File: 2328448.pdf
- Pages: 2
- Description: Advanced user guide for the Nero Radio 8117 micro.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Radio card Radio 8117 micro Рassport 2. Specifications Supply voltage range AC/DC, V............................................................................................................................~9-24/=12-30 Consumed current, mA ...................................................................................................................................................NMT 100 Maximum permissible switching current, A...............................................................................................................5 (at cos=1) Number ochannels.........................................................................................................................................................................2 Command duration (for each channel), s..................................................................................................................................1,5 Operating frequency range, MHZ.................................................... .. - .................................................................. 433,05 434,79 Number of recorded remote control codes .............................................................................................................................500 Overall dimensions,mm.................................................................................................................................................98×32×22 Operating temperature range, °C........................................................................................................................from -30 to +50 Connector wires section.....................................................................................................................................................0,5 mm2 Degree of case protection ......................................................................................................................................................IP55 - control using the Radío series remote controls; 3. Special features - supporting a new improved dynamic radio protocol with high range and noise immunity; - 2 channels to control other manufacturers automation; The product is not intended to be installed and operated in explosive and fire hazardous areas and does not require protective grounding. - supporting remote controls with feedback (see remote control instructions); - retransmission the dynamic code of the Radio series remotes. 4. Connection Connecting wires and cables with polyethylene insulation or sheath are not allowed. It is not allowed to install the device at a distance of less than 1 m from heating appliances. The holes in the cable glands must be made with a tool of a smaller diameter than the inserted cable. 5. Remote control programming The radio card Radio 8117 micro is designated to control the automation units of sliding, swinging, sectional doors and barriers. 1. Designation Channel 1 Channel 2 Antenna Programming button (light indicator) ~ 9–24 В = 12–30 В Power supply General/com Figure 1 — Radio card connection Action Indication 1. Enter the device into remote control programming mode (remote control PM) Press and hold the Programming button for more than 4 s. Indicator lamp is red. 2. Select a channel for remote control record Press and hold the Programming button for more than 1 s (channels change circle-wise). 2 – 2nd channel. The number of red blinking 1 – 1st channel; 3. Record remote control channel to the device memory One channel of the remote control can be recorded in only one of the two channels of the device, i.e., two channels cannot be recorded in one channel of the remote control. Since 2019, most remote controls are available with a dynamic code as the factory setting. See the instructions for the remote control for details. Radio 8101-1M b) in static mode: press briefly the remote control button (less than 1 s). a) in dynamic mode: press the remote control button and hold it for more than 2 s; - the channel is recorded: 1 beep l and 1 diode blink for the recorded channel; During recording, the device indicator light flashes green short-long-short. If the remote control is already recorded, the indicator flashes green briefly. Remote control indication in dynamic mode with feedback: If the memory is full, the indicator flashes yellow for 3 s. - the channel is not recorded: 3 beeps and 3 diode blinks for the recorded channel (see the instructions for the remote control). Radio 8101-2M 8101-4M b) in static mode: press briefly the recordable button. a) in dynamic mode: press the recordable remote control button and, while holding it, briefly press any other one; Radio 8101-5 8101-15 2) press briefly the «STOP» button. c) in dynamic mode with feedback: 1) select a recordable channel; 2) record the channel: -press simultaneously the «STOP» and «UP» buttons; a) in dynamic mode: b) in static mode: 1) select a recordable channel; 1) select a recordable channel; 2) record the channel: press the «STOP» button and, without releasing it, briefly press the «UP» button, then release both buttons. - receive the remote control signal about successful recording to the device (for more details, see the instructions for the remote). -release the UP button, without releasing «STOP» Action Indication 3. Delete remote control channel from device memory (remote control PM) 8101-1M Radio 2) remove the remote control: press the remote control button and hold it for more than 1 s. b) in static mode: press the remote control button and hold it for more than 1 s. 1) enter the remote control into programming mode: press the button 3 times in a row, and for the fourth one - hold the button for 4 s. The pressing interval should not exceed 1 s; a) in dynamic mode: Upon removal, the device light indicator will flash for a long time and continue to flash in red. In PM, the remote control light indicator flashes red. 8101-2M 8101-4M Radio a) in dynamic mode: press the button of the deleted channel and, holding it, press any other and hold it for more than 1 s, then release both buttons; b) in static mode: press and hold the button of the deleted channel for more than 1 s. Remote control indication in dynamic mode with feedback: -channel deleted: 2 beeps and 2 diode blinks for the deleted channel; -channel has not been deleted: 3 beeps and 3 diode blinks of the deleted channel (see instructions for the remote control) in red. The device light indicator will flash for a long time and continue to flash. Radio 8101-15 8101-5 a) in dynamic mode: 1) select the deleted channel; 2) record the channel, press the «STOP» button and without releasing press briefly the «DOWN» button, release both buttons. b) in dynamic mode: 1) select the deleted channel; c) in dynamic mode with feedback: 1) select the deleted channel; 2) record the channel, -press simultaneously the «STOP» and «DOWN» buttons; -release the «DOWN» button without releasing the «STOP» button (to receive the remote control signal about successful removal from the device, see the instructions for the remote control for more details). 2) press briefly the «STOP» button. 4. Delete channels of all remote controls from the device memory (remote controls PM) Press and hold the Programming button for more than 8 s. The light indicator flashes red twice for a long time. 5. Remove the device from the programming mode of the remote controls Press briefly the Programming button. Light indication stops. In case of inactivity, the device will automatically exit programming mode after 32 s The device can operate in one of three modes. 6. Mode of operation Single-channel mode (command duration is 1.5 s) is used to control a single object. For example, a barrier: 1st channel is responsible for the UP direction, and the second – DOWN direction. In this case, control is performed by all remote controls recorded in both channels of the device (see Figure 2). Two-channel mode (factory setting). Command duration is 1.5 s. It is used to control two automation objects. However, it should be taken into account that the radio card has one common input (3 “com” terminal), and it is not possible to connect it to different potentials at the same time (see Figure 3) Continuous command mode (command duration is infinite). It is used to control automation objects in which a continuous command is required, for example, a command to block the doors or gates automation. However, it should be taken into account that the radio card has one common input (3 “com” terminal), and it is not possible to connect it to different potentials at the same time (see Figure 4). Barrier/door control unit Figure 2 — Single-channel mode Figure 3 — Two-channel mode 1 1 - + Сh Сh 1 2 3 4 5 Barrier/door control unit Barrier/door control unit com - + Сh Сh 1 2 3 4 5 com - + Сh Сh com 1 2 3 4 5 Figure 4 — Continuous command mode Sliding door control unit - + Сh Сh com 1 2 3 4 5 lock P
Similar Manuals in the Control Unit Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Contrive QBK |
Guide: Contrive QBK (97K22Z, Upd.11-05-2026) |
20 | 1449 | 348 | 11-05-2026 | view all manuals | |
Honeywell SM152 Series |
PDF User Manual (@7EA28F), Honeywell SM152 Series Control Unit (08-08-2026) |
26 | 270 | 65 | 08-08-2026 | view all manuals | |
Siemens SINUMERIK 840D |
SINUMERIK 840D (Control Systems ePDF User Manual, #NPYG5Y) |
370 | 1278 | 294 | 06-05-2026 | view all manuals | |
Enclustra Mercury XU5 |
PDF User Guide (@WN6N8A), Enclustra Mercury XU5 Computer Hardware (23-03-2026) |
6 | 659 | 113 | 23-03-2026 | view all manuals | |
H3C S9500E Series |
H3C S9500E Series Guide (Interface configuration manual), @LS54T5 |
36 | 1454 | 349 | 22-08-2026 | view all manuals | |
Pilz PNOZ m EF 1MM |
Pilz Control Unit Operating manual (File: PDF, 28-08-2026) |
49 | 609 | 110 | 28-08-2026 | view all manuals |