NetApp DE5600 Manuals

2 pdf manual(s) NetApp DE5600 for free download (Document Types: Quick install manual, Hardware cabling manual)

Available Documents for DE5600:

NetApp DE5600 Quick install manual Main Page Preview

Quick install manual [PDF] (2 pages)

  • Brand: NetApp
  • Model: DE5600
  • Format: PDF
  • Key Aspects: Risk Mitigation and Accident Prevention, Troubleshooting Information, Component Overview and Descriptions
  • Updated: 24.06.2026
  • Source File: 1425627.pdf
  • Pages: 2
  • Description: Technical instruction manual for the NetApp DE5600.

Document Preview & Text Transcription

WARNING (W03) Risk of exposure to laser radiation – Do not disassemble or remove any part of a Small Form-factor Pluggable (SFP) transceiver because you might be exposed to laser radiation. ATTENTION Potential damage to equipment (Network Telecommunications Equipment (NEBS) Ethernet cable installations only) – The intra-building port(s) (Ethernet maintenance ports) of this equipment is suitable for connection to intra-building or unexposed wiring or cabling only. The intra-building port(s) of this equipment must not be metallically connected to interfaces that connect to the Outside Plant (OSP) or its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not suffi cient protection in order to connect these interfaces metallically to OSP wiring. The cable shall be Shielded Twisted Pair (STP) and must be grounded at both ends to meet the intra-building lightning requirements from section 4.6.9.2 of GR-1089-CORE, Issue #5. In this step, you connect the DE5600 drive tray to either an E2600 controller-drive tray, a DE1600 drive tray, or to another DE5600 drive tray in the storage array. For more information about the E2600 controller-drive tray, refer to the E2600 Controller-Drive Tray Quick Install Guide or the E2600 Controller-Drive Tray Installation Guide. Host-to-Controller Cabling Attach the appropriate cables and components for the relevant protocol (FC, SAS, or Ethernet). Choose the host connection confi guration. • Direct topology – Connect the cable from the host port on the controller to either an HBA port, a SAS port, a host channel adapter (HCA) Fibre Channel port, or an Ethernet adapter (iSCSI) on the host. The fi gures on the next page all show the HBA port option on the host. • Switch or fabric topology – Connect the cable from the host port on the controller to a port on the switch, and make sure that the HBA and the controller are in the same zone on the switch. • Mixed topology – Use a combination of direct topology and fabric topology. 5.1 5.2 5.3 5.4 Repeat step 5.1 through step 5.2 for each controller and host channel that you intend to use. When you are fi nished, label each end of the cable with information about its connection. Connect the cables 5 Install the drives 4.2 WARNING (W18) Risk of bodily injury – Do not use equipment in the cabinet as a shelf or workspace. Beginning with the fi rst drive slot on the left side of the drive tray, place the drive on the slot guides, and slide the drive all the way into the slot. Push the drive handle down to lock the drive securely in place. Install the second drive to the right of the fi rst drive. Install the other drives to the right of the installed drives. 4.1 4.3 4.4 4 Before you begin 1 For warnings, refer to the printed Safety Notices document. For detailed installation instructions, refer to the E2600 Controller- Drive Tray Installation Guide, located on the SANtricity™ ES Storage Manager Installation DVD. What you need for assembly: DE5600 drive tray (for connection to an E2600 controller-drive tray): • One two-unit (2U) -high DE5600 drive tray • Two Small Form-factor Pluggable (SFP) transceivers • One cabinet-mounting hardware kit Options: • Drives (two minimum for each drive tray, 192 maximum for each storage array) • DC power cords for the optional –48 VDC power option • Two SFP transceivers for each fi ber-optic cable (only one SFP transceiver is required for direct attachment to the host bus adapter [HBA]) • Two fi ber-optic cables or two copper cables for each drive tray connection If you have any questions about the fi rmware or your confi guration, contact your Customer and Technical Support representative. Tools: • A medium fl at-blade screwdriver • A No. 2 Phillips screwdriver • Anti-static protection • Labels – To help you to identify cable connections and to more easily trace cables • A cart – To hold the drive tray and its components • A fl ashlight 1.1 1 Mounting Holes on the Industry-Standard Cabinet 2 Adjustment Screws for Locking the Length of the Mounting Rail 3 Mounting Rail 4 Clip for Securing the Rear of the Drive Tray From the front of the cabinet, with the mounting-rail fl anges inside of the cabinet’s mounting rail assemblies, use the Phillips screwdriver to loosely tighten only the lower screw. From the rear of the cabinet, use the Phillips screwdriver to loosely tighten the two screws. Do not completely tighten the screws until you have installed the drive tray in the cabinet. Repeat step 2.1 through step 2.3 for the right mounting rail. Tighten the fl at-head rail adjustment screws on both mounting rails. Install the mounting rails 2 You can install the DE5600 drive tray into an industry-standard cabinet. There must be a minimum depth of 76 cm (30 in.) between the front EIA support rails and the rear EIA support rails. Position the mounting rails in the cabinet. • If you are installing the mounting rails above an existing tray, position the mounting rails directly above the tray. • If you are installing the mounting rails below an existing tray, allow 8.9-cm (3.5-in.) vertical clearance for the DE5600 drive tray. 2.1 1 2 3 4 1 2.2 2.3 2.4 2.5 DE5600 Drive Tray – Rear View 3.2 3.3 3.4 3.5 3.6 1 Screws Secure the side of the drive tray to the mounting rails by inserting one M4 screw through the side sheet metal of the drive tray into the captured nut on the side of the mounting rail, and tightening the screw. Repeat this step for the other side. Attach the front end caps onto the front of the drive tray. 1 1 Environmental Services Module (ESM) Canister 2 Power-Fan Canister 3 DC Power Connectors Remove the two front end caps by unsnapping them from the frame. Set them aside. With the help of one other person, place the rear of the drive tray on the mounting rails. Slide the drive tray into the cabinet, and verify that the rear of the drive tray is secured by the hold-down clips at the rear of each mounting rail. Secure the front of the drive tray to the cabinet. Use the two screws to attach the fl ange on each side of the front of the drive tray to the mounting rails. Screws for Securing the Front of the DE5600 Drive Tray AC DC ! AC DC ! 2 1 3 2 1 3 ! DC DC ! DC DC 1 Environmental Services Module (ESM) Canister 2 Power-Fan Canister 3 AC Power Connectors Quick Install Guide for the DE5600 Drive Tray 52889- 00A Storage System WARNING (W08) Risk of bodily injury – Two persons are required to safely lift the component. With the help of one other person, remove the drive tray from the shipping box. DE5600 Drive Tray – Front View 3 Install the drive tray 3.1 >18 kg (39.7 lbs) 3 2 1 1 Left End Cap (Has the Drive Tray LEDs) 2 Drives 3 Right End Cap Attaching the Front End Caps to the DE5600 Drive Tray 1 2 1 Hinge Tab 2 Retainer 10.2 10.3 6.2 6.1 6.3 6.4 You must follow the power sequence in the order shown. To establish power redundancy for trays with two power supplies, use a separate power source for each power-fan canister. For additional redundancy, you may connect each DC power connector on the same power-fan canister to a different power source. IMPORTANT You must turn on the power to all connected drive tray before you turn on the power to the E2600 controller-drive tray. Performing this action makes sure that the controllers recognize each attached drive tray. Disconnect the two-pole 20-amp circuit breaker for the storage array. Make sure that all of the DC power switches on the DC-powered controller-drive tray and drive trays are turned off. Connect the DC power connector cables to the DC power connectors on the rear of the controller-drive tray and drive trays. Have a qualifi ed service person connect the other end of the DC Power connector cables to the DC power plant equipment. Turn on the Power switch on each power-fan canister in all of the installed drive trays. Turn on the Power switch on each power-fan canister in the controller- drive tray. NOTE When turning off the power to the storage array, perform the procedure in the reverse order. Turn off the power fi rst to the controller- drive tray, and then turn off the power to the drive trays. 6.5 6.6 10 Discover the storage array 10.5 10.4 10.1 March 2012 NetApp Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: + (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP Document comments: [email protected] Information Web: http://www.netapp.com Part Number: 52889-00, Rev. A Copyright © 2012 NetApp, Inc. All rights reserved. E2600 Controller-Drive Tray between Two Drive Trays for Redundancy and Tray Loss Protection Connecting Cables for Maximum Redundancy and Tray Loss Protection In the AMW, select the Setup tab, and select the Rename Storage Array link to name the storage array. You can use up to 30 alphanumeric characters, hyphens (-), pound signs (#), and underscores (_). Also on the Setup tab, click the Locate Storage Array link to fi nd the storage array in the cabinet. A white LED blinks on the front of the selected storage array. Physically label the storage array with its name. Click the Storage & Copy Services tab to see the storage array’s confi guration. If the storage array is not in the Optimal state, click the Needs Attention link. Follow the steps in the Recovery Guru. Select the Summary tab, and select Storage Array Profi le. By clicking the tabs, fi nd the controller fi rmware, NVSRAM, ESM fi rmware, drive product ID, and fi rmware version, and record them. Close the storage array profi le. 11 Perform a basic setup Confi gure the storage array 12 12.1 12.2 12.3 12.4 12.5 In the AMW, select the Setup tab. If the storage array is in the Optimal state, perform these tasks: Confi gure the storage array. Defi ne the hosts. Create new storage partitions. Select the Support tab, and click the Gather Support Information link. To set or change a password, in the AMW, select either the Set a Storage Array Password link under the Setup tab, or select Storage Array >> Security >> Set Password. 9.1 9.2 9.3 9 Install the software 1 2 WARNING (W16) Risk of bodily injury– Each tray has more than one power cord. To remove all electrical current from the devices, make sure that all of the power cords are disconnected from the power source and that the two-pole 20-amp circuit breaker for the storage array has been disconnected. Exp Exp Controller A Controller B ESM A ESM B ESM A ESM B SAS EXP SAS IN SAS EXP SAS IN SAS IN SAS IN SAS EXP SAS IN SAS EXP SAS IN SAS IN SAS IN Before performing this step, make sure that you have correctly confi gured the storage array IP addresses as described in the Initial Confi guration and Software Installation Guide for SANtricity ES Storage Manager. Start the SANtricity ES Storage Manager software from your management station either by typing SMclient and pressing Enter (UNIX OSs), or by navigating to the directory that contains the SMclient.exe fi le, typing SMclient, and pressing Enter (Windows OSs). The client software starts and shows the Enterprise Management Window (EMW). Select Tools >> Automatic Discovery from the EMW to discover the storage array. In the confi guration dialog, click OK to start the automatic discovery. Click the Devices tab of the EMW to see the storage arrays. Double-click the storage array that you want to manage. The associated Array Management Window (AMW) is launched. NOTE To add a storage array from outside the local subnetwork, use the manual discovery method. From the EMW, click the Add Storage Arrays link, and follow the instructions. 11.1 11.2 11.3 11.4 11.5 6 Turn on the DC power DC power is an option that is available for use with your E2600 controller-drive tray and DE5600 drive tray. If you choose to have –48 VDC power available, you need a qualifi ed service person to install the equipment that provides special DC power connectors to each power-fan canister in your storage array. WARNING (W14) Risk of bodily injury – A qualifi ed service person is required to make the DC power connection according to NEC and CEC guidelines. Two types of computers are associated with the storage array. • Hosts send I/O to the storage array. • Management stations manage the storage array. The type of operating system that the management station runs is the directory that you need to locate on the DVD. At this time, check the BIOS and device driver versions for your current Fibre Channel HBA, SAS HCA, or iSCSI Network Interface Card (NIC). If necessary, update them before proceeding. For HBAs, obtain the BIOS and device drivers directly from the vendor. For Microsoft Windows installations, • Install the StorPort device driver. • Install the MPIO multi-path driver on the host. On the SANtricity ES Storage Manager Installation DVD, locate the appropriate operating system (OS) directory. • Review the appropriate operating system and device driver readme fi les included on the SANtricity ES Storage Manager Installation DVD for additional information. Launch the SMIA executable fi le. Follow the instructions in the wizard, and select one of these installation methods: • For the Management Station designated as a monitor (for monitoring and sending alert notifi cations), select Management Station (full installation), and, when prompted, click Automatically Start Monitor. • For the Management Station that you will use to manage the storage array, select Management Station, and, when prompted, select Do Not Automatically Start the Monitor. • For all I/O hosts attached to the storage array, select Host, and, when prompted, select Do Not Automatically Start the Monitor. For more information, refer to the “Deciding on the Management Method” step in the Initial Confi guration and Software Installation Guide for SANtricity ES Storage Manager. For Out-of-band management, use one of the methods below to confi gure the controllers for network connectivity: Without a DHCP server Connect separate Ethernet cables to each controller. Manually confi gure the network settings on the controllers, using the guidelines and procedures from the “Manually Confi guring the Controllers” step in the Initial Confi guration and Software Installation Guide for SANtricity ES Storage Manager. With a DHCP server Connect separate Ethernet cables to each controller. Assign static IP addresses to the controllers. NOTE This method applies only to IPv4 networks. Stateless Address Autoconfi guration Connect separate Ethernet cables to each controller. NOTE This method applies only to IPv6 networks and does not require either a DHCP server or a router. 8 Determine the management method Both management methods are specifi c to the installation steps in Section 9. This section and those that follow concern confi guration of the entire storage array. • In-band management – Managing a storage array by using a storage management station to send commands through the host input/output (I/O) connection to the controller. • Out-of-band management – Managing a storage array by using a storage management station to send commands through the Ethernet connections on each controller. + - 1 2 3 4 1 Ground, Green/Yellow Wire 2 Return (Positive), Blue Wire 3 Supply (Negative), Brown Wire, –48 VDC 4 DC Power Connector WARNING (W12) Risk of electrical shock – This unit has more than one power source. To remove all power from the unit, all DC MAINS must be disconnected by removing all power connectors (see item 4 below) from the power supplies. 7 Turn on the AC power You must follow the power sequence in the order shown. To establish power redundancy for trays with two power supplies, use at least two different power distribution units (PDUs) in the cabinet. Split the power connections from each tray into the separate PDUs. Then connect the PDUs to external power receptacles that are on different circuits. IMPORTANT You must turn on the power to all connected drive trays before you turn on the power to the E2600 controller-drive tray. Performing this action makes sure that the controllers recognize each attached drive tray. Turn off all of the Power switches from the rear of the storage array, and make sure that all of the power cords are connected. If the main AC circuit breaker switches in the cabinet are not already turned on, turn on the circuit breaker switches. WARNING (W17) Risk of bodily injury – Each tray has more than one power cord. To remove all electrical current from the devices, make sure that all of the power cords are disconnected from the power source. 7.1 7.2 Turn on the Power switch on each power-fan canister in all of the installed drive trays. Turn on the Power switch on each power-fan canister in the E2600 controller-drive tray. NOTE When turning off the power to the storage array, perform the procedure in the reverse order. Turn off the power fi rst to the controller- drive tray, and then turn off the power to the drive trays. 7.4 7.3 8.a1 8.a2 8.b1 8.b2 8.c1
NetApp DE5600 Hardware cabling manual Main Page Preview

Hardware cabling manual [PDF] (230 pages)

  • Brand: NetApp
  • Model: DE5600
  • Format: PDF
  • Key Aspects: Best Practices for Everyday Use, Routine Functionality Testing, Pre-Deployment Preparation Steps
  • Updated: 09.08.2026
  • Source File: 1935535.pdf
  • Pages: 230
  • Description: Complete operating guide for the NetApp DE5600.

Document Preview & Text Transcription

NetApp™ Hardware Hardware Cabling Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP Document comments: [email protected] Information Web: http://www.netapp.com Part number: 52904-00, Rev. A April 2012 ii Copyright information Copyright information Copyright © 1994–2012 NetApp, Inc. All rights reserved. Printed in the U.S.A. No part of this document covered by copyright may be reproduced in any form or by any means— graphic, electronic, or mechanical, including photocopying, recording, taping, or storage in an electronic retrieval system—without prior written permission of the copyright owner. Software derived from copyrighted NetApp material is subject to the following license and disclaimer: THIS SOFTWARE IS PROVIDED BY NETAPP "AS IS" AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY DISCLAIMED. IN NO EVENT SHALL NETAPP BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. NetApp reserves the right to change any products described herein at any time, and without notice. NetApp assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by NetApp. The use or purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of NetApp. RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by the government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.277-7103 (October 1988) and FAR 52-227-19 (June 1987) Trademark information iii Trademark information NetApp, the NetApp logo, Network Appliance, the Network Appliance logo, Akorri, ApplianceWatch, ASUP, AutoSupport, BalancePoint, BalancePoint Predictor, Bycast, Campaign Express, ComplianceClock, Cryptainer, CryptoShred, Data ONTAP, DataFabric, DataFort, Decru, Decru DataFort, DenseStak, Engenio, Engenio logo, E-Stack, FAServer, FastStak, FilerView, FlexCache, FlexClone, FlexPod, FlexScale, FlexShare, FlexSuite, FlexVol, FPolicy, GetSuccessful, gFiler, Go further, faster, Imagine Virtually Anything, Lifetime Key Management, LockVault, Manage ONTAP, MetroCluster, MultiStore, NearStore, NetCache, NOW (NetApp on the Web), Onaro, OnCommand, ONTAPI, OpenKey, PerformanceStak, RAID-DP, ReplicatorX, SANscreen, SANshare, SANtricity, SecureAdmin, SecureShare, Select, Service Builder, Shadow Tape, Simplicity storage management software, Simulate ONTAP, SnapCopy, SnapDirector, SnapDrive, SnapFilter, SnapLock, SnapManager, SnapMigrator, SnapMirror, SnapMover, SnapProtect, SnapRestore, Snapshot, SnapSuite, SnapValidator, SnapVault, StorageGRID, StoreVault, the StoreVault logo, SyncMirror, Tech OnTap, The evolution of storage, Topio, vFiler, VFM, Virtual File Manager, VPolicy, WAFL, Web Filer, and XBB are trademarks or registered trademarks of NetApp, Inc. in the United States, other countries, or both. IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. A complete and current list of other IBM trademarks is available on the Web at www.ibm.com/legal/copytrade.shtml. Apple is a registered trademark and QuickTime is a trademark of Apple, Inc. in the U.S.A. and/or other countries. Microsoft is a registered trademark and Windows Media is a trademark of Microsoft Corporation in the U.S.A. and/or other countries. RealAudio, RealNetworks, RealPlayer, RealSystem, RealText, and RealVideo are registered trademarks and RealMedia, RealProxy, and SureStream are trademarks of RealNetworks, Inc. in the U.S.A. and/or other countries. All other brands or products are trademarks or registered trademarks of their respective holders and should be treated as such. NetApp, Inc. is a licensee of the CompactFlash and CF Logo trademarks. NetApp, Inc. NetCache is certified RealSystem compatible. iv Trademark information

DE5600: Related Instructions

Manuals from Other Manufacturers