NuAire MRXBOX-VSC Manuals

2 pdf manual(s) NuAire MRXBOX-VSC for free download (Document Types: Installation and maintenance manual, Installation & operating instructions manual)

NuAire MRXBOX-VSC Installation and maintenance manual Thumbnail

NuAire MRXBOX-VSC Installation and maintenance manual [PDF] (8 pages)

  • Identifier: id-882508
  • Brand: NuAire
  • Device: NuAire MRXBOX-VSC Controller
  • Type: Installation and maintenance manual, PDF
  • Key Aspects: Safety Recommendations and Warnings, Hardware Verification Checklists, Glossary of Technical Terms
  • UPD Date: 06.05.2026
  • Source File: 862050.pdf
  • Pages: 8
  • Description: Practical user guide for the NuAire MRXBOX-VSC.
Pages Preview:
  • NuAire MRXBOX-VSC Installation and maintenance manual preview - page 2
  • NuAire MRXBOX-VSC Installation and maintenance manual preview - page 3
  • NuAire MRXBOX-VSC Installation and maintenance manual preview - page 4
  • NuAire MRXBOX-VSC Installation and maintenance manual preview - page 5
  • NuAire MRXBOX-VSC Installation and maintenance manual preview - page 6
  • NuAire MRXBOX-VSC Installation and maintenance manual preview - page 7
  • NuAire MRXBOX-VSC Installation and maintenance manual preview - page 8
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 nuaire.co.uk 029 2085 8400 19. 07. 18. Document Number 671703 The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU MRXBOX-VSC Visual System User Control Installation and Maintenance 1.0 INTRODUCTION The MRXBOX-VSC is a user control from the Ecosmart range. These wall mounted user controls include a 3.5’’ colour LCD touchscreen display to provide improved user interface. The unit can be surface or semi-recessed mounted and is compatible with standard 2-gang recess back box. The control is manufactured from an all plastic construction and supplied with 10m of pre-plugged connection cable and surface mounting back box. Units are SELV (12 Vdc) with the power supplied from the fan unit via the pre-plugged cable. 2.0 DIMENSIONS 3.0 INSTALLATION The unit is supplied with back box suitable for surface mounting (see Figure 2 - Figure 6). If semi-recess (final projection from wall is approximately 7mm) is needed, a proprietary 2-gang back box (25mm deep minimum) may be used. Always physically check the suitability of the back box before fitting. In some instances, the earthing point of the back box may foul the unit and need to be removed. 1. Fix one end of the 10m cable to the fan’s Ecosmart connection point and route the cable to the mounting position. A C = Surface mounting depth B E = Screen width F = Screen depth D = Recessed mounting depth Dimensions A B C D E F MRXBOX-VSC 145 85 35 6 73 57 IMPORTANT INSTALLED ENVIRONMENT: 0-40°C and <90% RH (non-condensing) Caution: The unit must be installed away from any direct source of heat (e.g. radiators) and not in areas where it would be subjected to steam or water spray. The mounting surface must be free from vibration. 2. Unclip the front bezel from the unit and remove the 2 retaining screws, then remove the working section from the back box (see figure Figure 3). 3. Feed the cable through the knock-out hole in the base of the back box and mark the fixing point on the wall, drill appropriately sized holes at the required fixing points and insert the wall plugs. Fix the back box on to the wall (see figure Figure 4). 4. Plug the data cable into the socket (see figure Figure 5). 5. Fix the unit back into the back box using the screws supplied, then clip the bezel back on the unit again noting which way is up. (Top is printed on the inside face of the bezel and middle section) (see figure Figure 6). Fix back box to wall using screws. Feed cable through hole in back box. Bezel Front of unit Back box. TOP Plug end mounted into the PCB socket inside the front half of the unit. Note that the data cable socket is positioned at the top corner of the unit. Front of unit Back box Remove the bezel and 2 screws to detach front of unit from back box. Bezel Wall To fan connector box terminal marked NET 10m sensor connection wire (supplied) Clearance aperture for wire should be approx. 20mm dia to allow passage of plug end. Allow approx 120mm of wire through for fitting to the backplate. Wire can be located behind a wall panel or fixed to wall surface. Figure 1. Unit Dimensions Figure 2. Figure 3. Figure 4. Figure 5. Figure 6.
NuAire MRXBOX-VSC Installation & operating instructions manual Thumbnail

NuAire MRXBOX-VSC Installation & operating instructions manual [PDF] (8 pages)

  • Identifier: id-1149407
  • Brand: NuAire
  • Device: NuAire MRXBOX-VSC Control Panel
  • Type: Installation & operating instructions manual, PDF
  • Key Aspects: Device Specifications Overview, User Training Recommendations, Warranty and Service Information
  • UPD Date: 03.06.2026
  • Source File: 1008972.pdf
  • Pages: 8
  • Description: Instruction booklet for the NuAire MRXBOX-VSC.
Pages Preview:
  • NuAire MRXBOX-VSC Installation & operating instructions manual preview - page 2
  • NuAire MRXBOX-VSC Installation & operating instructions manual preview - page 3
  • NuAire MRXBOX-VSC Installation & operating instructions manual preview - page 4
  • NuAire MRXBOX-VSC Installation & operating instructions manual preview - page 5
  • NuAire MRXBOX-VSC Installation & operating instructions manual preview - page 6
  • NuAire MRXBOX-VSC Installation & operating instructions manual preview - page 7
  • NuAire MRXBOX-VSC Installation & operating instructions manual preview - page 8
Document Preview & Text Transcription (Main Page)
Click to expand and read text
MRXBOX-VSC Visual System User Control Installation & Operating Instructions Due to the higher current consumed by the MRXBOX-VSC, the max cable run between the fan control and the MRXBOX-VSC must be limited to 50m. 1 Nuaire Limited Western Industrial Estate Caerphilly United Kingdom CF83 1NA T: 029 2085 8400 F: 029 2085 8444 E: [email protected] W: www.nuaire.co.uk The EMC Directive 2004/108/EC The Low Voltage directive 2006/95/EC Remove the bezel and 2 screws to detach front of unit from back box. 10m sensor connection wire (supplied). Clearance aperture for wire should be approx 20mm dia to allow passage of plug end. Allow approx 120mm of wire through for fitting to the backplate. Wire can be located behind a wall panel or fixed to wall surface. Wall To fan connector box terminal marked NET Plug end mounted into the PCB socket inside the front half of the unit. Note that the data cable socket is positioned at the top corner of the unit. Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Fix back box to wall using screws. Feed cable through hole in back box. Bezel Front of unit. Back box. Bezel Front of unit Back box. TOP 09. 03. 16. Leaflet Number 671703 MRXBOX-VSC is a user control from the Ecosmart range. They have a 3.5in colour LCD touchscreen display to provide improved user interface. The unit can be surface or semi-recessed mounted and is compatible with standard 2-gang recess back box. MRXBOX-VSC– the unit is all plastic construction and supplied with 10m of pre-plugged connection cable and surface mounting back box. The units are SELV (12V d.c.) with the power supplied from the fan unit via the pre-plugged cable. 1.0 Installation INSTALLED ENVIRONMENT 0-40oC and up to 90% RH non-condensing. Caution: The unit must be installed away from any direct source of heat (e.g. radiators) and not in areas where it would be subjected to steam or water spray. The mounting surface must be free from vibration. The unit is supplied with back box suitable for surface mounting. (see Figs. 1 - 5). If semi-recess (final projection from wall is 7mm approx) is needed, a proprietary 2-gang back box (25mm deep min.) may be used. Always physically check the suitability of the back box before fitting. In some instances, the earthing point of the back box may foul the unit and need to be removed. a) Fix one end of the 10m cable to the fan’s Ecosmart connection point and route the cable to the mounting position. b) Unclip the front bezel from the unit and remove the 2 retaining screws, then remove the working section from the back box. (see Fig. 2). c) Feed the cable through the knock-out hole in the base of the back box and mark the fixing point on the wall. Drill appropriately sized holes at the fixing points and insert the wall plugs. Fix the back box on to the wall. (see Fig 3). d) Plug the data cable into the socket. (see Fig. 4). e) Fix the unit back into the back box using the screws supplied, then clip the bezel back on the unit again noting which way is up. (Top is printed on the inside face of the bezel and and middle section). (see Fig. 5). 2.0 Data Cable Installation A 4-core SELV data cable is used to connect the control to the fan. Do not run data cable in the same conduit as the mains cables and ensure there is a 50mm separation between the data cable and other cables. For cable lengths in excess of 10m a MRXBOX-JB will be required to provide sufficient power. Keep the number of cable joints to a minimum to ensure the best data transmission efficiency between devices.

Similar Manuals in the Controller, Control Panel Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Sungale Cloud Frame CPF1032

Tablet #4P4NEB

29 1105 255 06-06-2026 view all manuals
Danfoss ECL Comfort 296

#9A9T1I: ECL Comfort 296 Controller Operating manual

8 839 210 08-03-2026 view all manuals
Spectra 1725

Spectra Control Panel Reference & installation manual (File: PDF, 14-08-2026)

67 1247 300 14-08-2026 view all manuals
AMX CP-20A

CP-20A (Control Panel ePDF Manual, #6I1EWW)

44 2.02 Mb 1383 236 27-03-2026 view all manuals
Lexmark MS810de

User Manual: Lexmark MS810de (I6VQ45, Upd.31-08-2026)

1 1111 223 31-08-2026 view all manuals
EMKO RS PRO EPM-3790

RS PRO EPM-3790 Instruction manual - Y9BL4V

36 624 119 27-06-2026 view all manuals