Omron RS8 Manuals
2 pdf manual(s) Omron RS8 for free download (Document Types: Instruction manual)
Omron RS8 Instruction manual [PDF] (2 pages)
- Identifier: id-1034909
- Brand: Omron
- Device: RS8 Blood Pressure Monitor
- Type: PDF
- Key Aspects: Detailed Installation Instructions, Critical Operational Precautions, Periodic Inspection Checklists
- UPD Date: 29.05.2026
- Source File: 1123556.pdf
- Pages: 2
- Description: Advanced user guide for the Omron RS8.
Click to expand and read text
Introduction Thank you for purchasing the OMRON RS8 Wrist Blood Pressure Monitor. The OMRON RS8 is a compact and easy to use blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re-inflation the device uses its advanced “IntelliSense” technology. Intended Use This product is designed to measure the blood pressure and pulse rate of people within the range of the designated wrist cuff, following the instructions in this instruction manual. It is mainly designed for general household use. Please read the Important Safety Information in this instruction manual before using the unit. Please read this instruction manual thoroughly before using the unit. Please keep for future reference. For specific information about your own blood pressure, CONSULT YOUR DOCTOR. Important Safety Information Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis. Please read this section carefully before using the unit. Warning: • Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. (General Usage) • Always consult your doctor. Self-diagnosis of measurement results and self-treatment are dangerous. • People with severe blood flow problems, or blood disorders, should consult a doctor before using the unit, as cuff inflation can cause internal bleeding. (Battery Usage) • If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Consult a doctor immediately. Caution: • Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property. (General Usage) • Do not leave the unit unattended with infants or persons who cannot express their consent. • Do not use the unit for any purpose other than measuring blood pressure. • Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit. • Do not disassemble the unit or wrist cuff. • Do not operate the unit in a moving vehicle (car, airplane). (Battery Usage) • If battery fluid should get on your skin or clothing, immediately rinse with plenty of clean water. • Use only two “AAA” alkaline (LR03) batteries with this unit. Do not use other types of batteries. • Do not insert the batteries with their polarities incorrectly aligned. • Replace old batteries with new ones immediately. Replace both batteries at the same time. • Remove the batteries if the unit will not be used for three months or more. • Do not use new and used batteries together. General Precautions • Do not apply strong shocks and vibrations to or drop the unit. • Do not take measurements after bathing, drinking alcohol or caffeine, smoking, exercising or eating. • Do not inflate the wrist cuff when it is not wrapped around your wrist. • Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the Technical Data Section. • Read and follow the “Correct Disposal of This Product” in the Technical Data Section when disposing of the device and any used accessories or optional parts. 1. Overview Main unit: A. Wrist cuff B. Battery compartment C. Display D. User ID selection switch E. Weekly average ( ) button F. Memory ( ) button G. Transfer area H. START/STOP button I. Date/Time setting ( ) button J. Date/Time setting ( ) button Display: A. Memory symbol B. Systolic blood pressure C. Diastolic blood pressure D. Battery low symbol E. Heartbeat symbol (Flashes during measurement) F. Irregular heartbeat symbol G. Average value symbol H. Date/Time display I. Morning average symbol J. Evening average symbol K. Blood pressure trend graph L. Blood pressure level indicator M. Positioning indicator N. Positioning symbol O. Cuff wrapping guide P. User ID symbol (A or B) Q. OK symbol R. Transfer indicator S. Deflation symbol T. Pulse display and Memory number U. Movement error symbol 2. Preparation 2.1 Installing/Replacing the Batteries 1. Remove the battery cover. 2. Insert two 1.5 V “AAA” alkaline (LR03) batteries as indicated in the battery compartment and then replace the battery cover. Notes: • If the battery low symbol ( ) appears on the display, turn off the unit then replace both batteries at the same time. • The measurement values continue to be stored in memory even after the batteries are replaced. Disposal of used batteries should be carried out in accordance with the national regulations for the disposal of batteries. 2.2 Setting the Date and Time 1. Press the button. 2. Set the monitor to the correct date and time before taking a measurement for the first time. 3. Press the START/STOP button to store the setting. Notes: • If the batteries have been removed, the date and time setting will need to be reset. • If the date and time are not set, “-:--” appears during or after measurement. 3. Using the Unit 3.1 Applying the Wrist Cuff Do not apply over clothing. 1. Put your arm through the cuff loop. Your palm should face upward. 2. Wrap the wrist cuff around your wrist. Wrap the wrist cuff securely around the wrist for taking accurate measurements. Make sure that the wrist cuff does not cover the protruding part of the wrist bone (ulna) on the outside of the wrist. Notes: • You can take a measurement on either your left or right wrist. • If the wrist cuff comes off, assemble as shown in the figure. 3.2 How to Sit Correctly To take a measurement, you need to be relaxed and comfortably seated, under comfortable room temperature. No bathing, drinking alcohol or caffeine, smoking, exercising or eating 30 minutes before taking a measurement. • Sit on a chair with your feet flat on the floor. • Sit upright with your back straight. • The cuff should be at the same level as your heart. • Relax your wrist and hand. Do not bend your wrist back, clench your fist, or bend your wrist forward. 3.3 Taking a Reading Notes: • To cancel a measurement, press the START/STOP button at any time during measurement. • Remain still while taking a measurement. 1. Select your User ID. 2. Press the START/STOP button. All the symbols appear on the display. While your position is improper, the Positioning symbol and the Positioning indicator flash, when you are in proper position the Positioning symbol lights on the display. After the Positioning symbol lights for more than 2 seconds, the wrist cuff will start to inflate automatically. Cuff Wrapping Guide The Cuff Wrapping Guide is a unique feature that indicates if the cuff is not wrapped tightly enough around the wrist. Even when the is displayed, a blood pressure reading will be taken. Note: This reading is NOT reliable due to the incorrect wrapping of the cuff. Please wrap the cuff again, taking care to wrap it correctly and take the measurement again. When the is displayed, the cuff is correctly wrapped tightly enough on the wrist and the reading is accurate and reliable. 3. Undo the wrist cuff and remove the unit. 4. Press the START/STOP button to turn off the monitor. The monitor automatically stores the measurement in its memory. It will automatically turn off after two minutes. Important: • Recent research suggests that the following values can be used as a guide to high blood pressure for measurements taken at home. This criteria is for home blood pressure measurement. • Your blood pressure monitor includes an irregular heartbeat feature. Irregular heartbeats can influence the results of the measurement. The irregular heartbeat algorithm automatically determines if the measurement is usable or needs to be repeated. If the measurement results are affected by irregular heartbeats but the result is valid, the result is shown together with the irregular heartbeat symbol ( ). If the irregular heartbeats cause the measurement to be invalid, no result is shown. If the irregular heartbeat symbol ( ) is shown after you have taken a measurement, repeat the measurement. If the irregular heartbeat symbol ( ) is shown frequently, please make your doctor aware of it. • If you move during measurement, the movement error symbol ( ) will appear on the display. Keep still and repeat the measurement. Notes: • Wait 2 - 3 minutes before taking another blood pressure measurement. Waiting between readings allows the arteries to return to the condition prior to taking the blood pressure measurement. • The blood pressure can differ between the right arm and the left arm, and therefore also the measured blood pressure values can be different. OMRON recommends to always use the same arm for measurement. If the values between the two arms differ substantially, please check with your physician which arm to use for your measurement. Warning: Self-diagnosis of measured results and treatment are dangerous. Please follow the instructions of your doctor. 3.4 Setting the Positioning Sensor 1. Press and hold the button to reset the Positioning sensor. The Positioning sensor is set “on” as default. 2. Press the START/STOP button to store the setting. 3.5 Using the Memory Function The monitor automatically stores the result up to 100 sets for each user (A and B). It can also calculate an average reading based on the measurements from the last three readings taken within 10 minutes. If there are only two readings in memory for that period, the average will be based on two readings. If there is one reading in memory for that period, the average will be based on one reading. Notes: • If the memory is full, the monitor will delete the oldest readings. • When viewing the reading taken without setting the date and time, “-:--” is displayed instead of the date and time. To View the Average Value 1. Select your User ID. 2. Press the button. Note: If there are no measurements results stored in the memory, the screen to the right is displayed. Wrist Blood Pressure Monitor Model RS8 Instruction Manual IM-HEM-6310F-E-EN-01-11/2012 1883294-6A A E D H J I C F G B A B C D E F G I J K P Q R M N O L H S U T Year Month Day Hour Minute 1) Push the button to change. • Hold down to advance the digit rapidly. 2) Push the button to confirm. • Next setting appears. 1 2 The monitor is in proper position. The monitor is higher than the heart. The monitor is lower than the heart. Systolic Blood Pressure Above 135 mmHg Diastolic Blood Pressure Above 85 mmHg Cuff Wrapping Guide START INFLATE DEFLATE COMPLETE Alternating date/time display
Omron RS8 Instruction manual [PDF] (2 pages)
- Identifier: id-1144759
- Brand: Omron
- Device: RS8 Blood Pressure Monitor
- Type: PDF
- Key Aspects: Warranty and Service Information, Error Code Explanations, Device Specifications Overview
- UPD Date: 07.07.2026
- Source File: 1013620.pdf
- Pages: 2
- Description: Product setup manual for the Omron RS8.
Click to expand and read text
Introduction Thank you for purchasing the OMRON RS8 Wrist Blood Pressure Monitor. The OMRON RS8 is a compact and easy to use blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re-inflation the device uses its advanced “IntelliSense” technology. Intended Use This product is designed to measure the blood pressure and pulse rate of people within the range of the designated wrist cuff, following the instructions in this instruction manual. It is mainly designed for general household use. Please read the Important Safety Information in this instruction manual before using the unit. Please read this instruction manual thoroughly before using the unit. Please keep for future reference. For specific information about your own blood pressure, CONSULT YOUR DOCTOR. Important Safety Information Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis. Please read this section carefully before using the unit. Warning: • Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. (General Usage) • Always consult your doctor. Self-diagnosis of measurement results and self-treatment are dangerous. • People with severe blood flow problems, or blood disorders, should consult a doctor before using the unit, as cuff inflation can cause internal bleeding. (Battery Usage) • If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Consult a doctor immediately. Caution: • Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property. (General Usage) • Do not leave the unit unattended with infants or persons who cannot express their consent. • Do not use the unit for any purpose other than measuring blood pressure. • Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit. • Do not disassemble the unit or wrist cuff. • Do not operate the unit in a moving vehicle (car, airplane). (Battery Usage) • If battery fluid should get on your skin or clothing, immediately rinse with plenty of clean water. • Use only two “AAA” alkaline (LR03) batteries with this unit. Do not use other types of batteries. • Do not insert the batteries with their polarities incorrectly aligned. • Replace old batteries with new ones immediately. Replace both batteries at the same time. • Remove the batteries if the unit will not be used for three months or more. • Do not use new and used batteries together. General Precautions • Do not apply strong shocks and vibrations to or drop the unit. • Do not take measurements after bathing, drinking alcohol or caffeine, smoking, exercising or eating. • Do not inflate the wrist cuff when it is not wrapped around your wrist. • Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the Technical Data Section. • Read and follow the “Correct Disposal of This Product” in the Technical Data Section when disposing of the device and any used accessories or optional parts. 1. Overview Main unit: A. Wrist cuff B. Battery compartment C. Display D. User ID selection switch E. Weekly average ( ) button F. Memory ( ) button G. Transfer area H. START/STOP button I. Date/Time setting ( ) button J. Date/Time setting ( ) button Display: A. Memory symbol B. Systolic blood pressure C. Diastolic blood pressure D. Battery low symbol E. Heartbeat symbol (Flashes during measurement) F. Irregular heartbeat symbol G. Average value symbol H. Date/Time display I. Morning average symbol J. Evening average symbol K. Blood pressure trend graph L. Blood pressure level indicator M. Positioning indicator N. Positioning symbol O. Cuff wrapping guide P. User ID symbol (A or B) Q. OK symbol R. Transfer indicator S. Deflation symbol T. Pulse display and Memory number U. Movement error symbol 2. Preparation 2.1 Installing/Replacing the Batteries 1. Remove the battery cover. 2. Insert two 1.5 V “AAA” alkaline (LR03) batteries as indicated in the battery compartment and then replace the battery cover. Notes: • If the battery low symbol ( ) appears on the display, turn off the unit then replace both batteries at the same time. • The measurement values continue to be stored in memory even after the batteries are replaced. Disposal of used batteries should be carried out in accordance with the national regulations for the disposal of batteries. 2.2 Setting the Date and Time 1. Press the button. 2. Set the monitor to the correct date and time before taking a measurement for the first time. 3. Press the START/STOP button to store the setting. Notes: • If the batteries have been removed, the date and time setting will need to be reset. • If the date and time are not set, “-:--” appears during or after measurement. 3. Using the Unit 3.1 Applying the Wrist Cuff Do not apply over clothing. 1. Put your arm through the cuff loop. Your palm should face upward. 2. Wrap the wrist cuff around your wrist. Wrap the wrist cuff securely around the wrist for taking accurate measurements. Make sure that the wrist cuff does not cover the protruding part of the wrist bone (ulna) on the outside of the wrist. Notes: • You can take a measurement on either your left or right wrist. • If the wrist cuff comes off, assemble as shown in the figure. 3.2 How to Sit Correctly To take a measurement, you need to be relaxed and comfortably seated, under comfortable room temperature. No bathing, drinking alcohol or caffeine, smoking, exercising or eating 30 minutes before taking a measurement. • Sit on a chair with your feet flat on the floor. • Sit upright with your back straight. • The cuff should be at the same level as your heart. • Relax your wrist and hand. Do not bend your wrist back, clench your fist, or bend your wrist forward. 3.3 Taking a Reading Notes: • To cancel a measurement, press the START/STOP button at any time during measurement. • Remain still while taking a measurement. 1. Select your User ID. 2. Press the START/STOP button. All the symbols appear on the display. While your position is improper, the Positioning symbol and the Positioning indicator flash, when you are in proper position the Positioning symbol lights on the display. After the Positioning symbol lights for more than 2 seconds, the wrist cuff will start to inflate automatically. Cuff Wrapping Guide The Cuff Wrapping Guide is a unique feature that indicates if the cuff is not wrapped tightly enough around the wrist. Even when the is displayed, a blood pressure reading will be taken. Note: This reading is NOT reliable due to the incorrect wrapping of the cuff. Please wrap the cuff again, taking care to wrap it correctly and take the measurement again. When the is displayed, the cuff is correctly wrapped tightly enough on the wrist and the reading is accurate and reliable. 3. Undo the wrist cuff and remove the unit. 4. Press the START/STOP button to turn off the monitor. The monitor automatically stores the measurement in its memory. It will automatically turn off after two minutes. Important: • Recent research suggests that the following values can be used as a guide to high blood pressure for measurements taken at home. This criteria is for home blood pressure measurement. • Your blood pressure monitor includes an irregular heartbeat feature. If the irregular heartbeat symbol is shown with a result ( ), the result is valid. It is however recommended to repeat the measurement to confirm the presence of irregular heartbeats. If the irregular heartbeat symbol is shown with no result ( ), an error will be displayed. After an irregular heartbeat symbol has been displayed, wait 2 - 3 minutes and take another measurement. If the irregular heartbeat symbol continues to appear ( ), consult your physician. • If you move during measurement, the movement error symbol ( ) will appear on the display. Keep still and repeat the measurement. Notes: • Wait 2 - 3 minutes before taking another blood pressure measurement. Waiting between readings allows the arteries to return to the condition prior to taking the blood pressure measurement. • The blood pressure can differ between the right arm and the left arm, and therefore also the measured blood pressure values can be different. OMRON recommends to always use the same arm for measurement. If the values between the two arms differ substantially, please check with your physician which arm to use for your measurement. Warning: Self-diagnosis of measured results and treatment are dangerous. Please follow the instructions of your doctor. 3.4 Setting the Positioning Sensor 1. Press and hold the button to reset the Positioning sensor. The Positioning sensor is set “on” as default. 2. Press the START/STOP button to store the setting. 3.5 Using the Memory Function The monitor automatically stores the result up to 100 sets for each user (A and B). It can also calculate an average reading based on the measurements from the last three readings taken within 10 minutes. If there are only two readings in memory for that period, the average will be based on two readings. If there is one reading in memory for that period, the average will be based on one reading. Notes: • If the memory is full, the monitor will delete the oldest readings. • When viewing the reading taken without setting the date and time, “-:--” is displayed instead of the date and time. To View the Average Value 1. Select your User ID. 2. Press the button. Note: If there are no measurements results stored in the memory, the screen to the right is displayed. Wrist Blood Pressure Monitor Model RS8 Instruction Manual IM-HEM-6310F-E-EN-03-02/2015 1883294-6C A E D H J I C F G B A B C D E F G I J K P Q R M N O L H S U T Year Month Day Hour Minute 1) Push the button to change. • Hold down to advance the digit rapidly. 2) Push the button to confirm. • Next setting appears. 1 2 The monitor is in proper position. The monitor is higher than the heart. The monitor is lower than the heart. Systolic Blood Pressure Above 135 mmHg Diastolic Blood Pressure Above 85 mmHg Cuff Wrapping Guide START INFLATE DEFLATE COMPLETE Alternating date/time display 15B0338
RS8: Related Instructions
INSTRUCTION MANUAL OMRON Pedometer Model HJ-105 Professional operation guide for the Omron HJ-105 Pedometer. The manual describes technical overview, connectivity setup, specifications.
I608-E-03 SmartVision MX Userʼs Guide Complete operating guide for the Omron SmartVision MX Controller. The manual contains instructions for setup guidelines, technical guidelines, safety information, installation support.
CK3E-series Programmable Multi-Axis Controller Hardware User’s Manual I610-E1-01 CK3E-110 Programmable Multi-Axis Controller Advanced user manual for the Omron CK3E-1210 Controller. It outlines installation and safety, operational safety, energy usage.
1 New Product Switch Mode Power Supply (240/480-W Models) S8VK-WA New Three-phase 200-V Power Supplies A solution to the problem of phase imbalance required in Full operation manual for the Omron S8VK-WA Series Power Supply. It describes step-by-step cleaning instructions, functional overview, wiring setup, security instructions.
Vision Sensor FH/FHV Series Vision System User’s Manual FH-1£££/FH-1£££-££ FH-2£££-££/FH-2£££-££ FH-3£££/FH-3£££-££ FH-5£££-££/ Official operating instructions for the Omron fh series Machine Vision Systems. The guide focuses on installation procedures, operational guidelines, hardware components, backup procedures.
G-143 D4BS D4BS Safety-door Switch D4BS Safety-door Switch’s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Sa User reference manual for the Omron D4BS - Switch. It contains information on installation procedures, user preferences, testing procedures.
Similar Manuals in the Blood Pressure Monitor Category
Малая манжета и малая груша CSB2 Small Cuff and Inflation Bulb (HEM-CS24) IM-CSB-RU-01-06/2013 13E1292 • Instructions for use 2 • Р� Instructions for safe usage of the Omron HEM-CS24 Measuring Instruments. This guide presents software installation, safety, operational safety.
Microlife BP A6 PC IB BP A6 PC E-V10 3718 Microlife AG Espenstrasse 139 9443 Widnau / Switzerland www.microlife.com EN 1 RU 10 BG 20 RO 30 CZ � Instruction reference guide for the Microlife BP A6 PC Blood Pressure Monitor. It explains usage scenarios and device calibration, safety, maintenance guidelines.
Owner’s guide for the Microlife BP AG1-10 Blood Pressure Monitor. The manual elaborates on features and technical specifications, wiring setup, technical overview, replacement parts.
GB 1 Instruction Manual BPW-1000-EU Blood Pressure Monitor IB-BPW1000-0616-04.qxp_Layout 1 28/07/2016 13:07 Page 1 Service and user manual for the HoMedics BPW-1000-EU Blood Pressure Monitor. This manual explains startup procedures, reset instructions, performance optimization.