Orbit 57894 Manuals

3 pdf manual(s) Orbit 57894 for free download (Document Types: Abridged user manual, Operation & user’s manual)

Document Preview & Text Transcription

PN 57894-24 rB Models / Modelos: 27894, 27896, 27892, 27999, 28566, 28568, 57567, 57894, 57896, 57899, 57900 Users ManUal ManUal del UsUario RESET PROGRAM RAIN DELAY AUTO OFF SET CLOCK SET DATE BUDGET HOW OFTEN RUN TIME START TIME 2 Table of Contents Section 1: Get to know your timer . . . . . . . . . . . . . . . . .4 Section 2: Installation . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Section 3: Programming with Easy-Set Logic®. . . . . . .9 Section 4: Additional Features . . . . . . . . . . . . . . . . . . .11 Section 5: Reference . . . . . . . . . . . . . . . . . . . . . . . . . . .13 ENGLISH 3 Congratulations on selecting your new Orbit timer! With Orbit’s exclusive Easy-Set Logic®, simple programming and setup are combined with the latest timer technology and versatility. Your new timer provides convenience and flexibility, letting you run a fully automatic, a semi-automatic, or a manual watering program for all your watering needs. Although this timer is so easy to program that you likely will not need instructions, we recommend that you read this manual fully before installation so that you understand all of the advanced features.

Document Preview & Text Transcription

PN 94894-24 rA Models / Modèles / Modelos Modelli / Modele: 57894, 57896, 57899, 57900, 27894, 27896, 27892, 27999, 91894, 91896, 91892, 91899 Users Manual Manuel de l’utilisateur Manual del usuario Manuale d’uso INSTRUKCJA obsługi RESET PROGRAM RAIN DELAY 2 Table of Contents Section 1: Get to know your timer . . . . . . . . . . . . . . . . . 4 Section 2: Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Section 3: Programming with Easy-Set Logic™ . . . . . . 9 Section 4: Additional Features . . . . . . . . . . . . . . . . . . . 11 Section 5: Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 ENGLISH 3 Congratulations on selecting your new Orbit timer! With Orbit’s exclusive Easy-Set Logic™, simple programming and setup are combined with the latest timer technology and versatility. Your new timer provides convenience and flexibility, letting you run a fully automatic, a semi-automatic, or a manual watering program for all your watering needs. Although this timer is so easy to program that you likely will not need instructions, we recommend that you read this manual fully before installation so that you understand all of the advanced features. 4 A B C D E Lock and latch Weather Resistant Cover Dial Digital Display Battery Compartment Swing Door panel F RESET PROGRAM RAIN DELAY Section 1: Get to know your timer A B C D E F

Document Preview & Text Transcription

PN 57894-24 rA Models / Modèles / Modelos: 57894, 57896, 57899, 57900, 27894, 27896, 27892, 27999, 91894, 91896, 91892, 91899 Users Manual Manuel de l’utilisateur Manual del usuario RESET PROGRAM RAIN DELAY AUTO OFF SET CLOCK SET DATE BUDGET HOW OFTEN RUN TIME START TIME http://waterheatertimer.org/Woods-timers-and-manuals.html#sprinkler Table of Contents Section 1: Get to know your timer . . . . . . . . . . . . . . . . . 4 Section 2: Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Section 3: Programming with Easy-Set Logic™ . . . . . . 9 Section 4: Additional Features . . . . . . . . . . . . . . . . . . . 11 Section 5: Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2 ENGLISH 3 Congratulations on selecting your new Orbit timer! With Orbit’s exclusive Easy-Set Logic™, simple programming and setup are combined with the latest timer technology and versatility. Your new timer provides convenience and flexibility, letting you run a fully automatic, a semi-automatic, or a manual watering program for all your watering needs. Although this timer is so easy to program that you likely will not need instructions, we recommend that you read this manual fully before installation so that you understand all of the advanced features. 4 A B C D E Lock and latch Weather Resistant Cover Dial Digital Display Battery Compartment Swing Door panel F RESET PROGRAM RAIN DELAY AUTO OFF SET CLOCK SET DATE BUDGET HOW OFTEN RUN TIME START TIME Section 1: Get to know your timer 5 Buttons Function ENTER MANUAL To confirm a new setting To water manually clear To clear a setting PROGRAM To move to different programs: A, B, and C ARROW [  ] To skip to the next setting / watering station or move to other programs/settings ARROW [  ] To go back to the previous setting / watering station or move to other programs/settings RAIN DELAY To pause operation for 24-72 hours due to rain or other factors [ + ] To increase a numeric setting [ – ] To decrease a numeric setting Dial Position Function AUTO Set Program is running set clock Set clock time set date Year, Month, and Day start time Set time to begin watering Year, Month & Day run time Set watering duration for each station how often Set frequency of watering days budget Adjust overall watering as a percentage off Turn all stations/functions off Section 2: Installation Required Tools • Phillips Screwdriver • Wire Strippers Installation Steps 1. Select a Location 2. Mount the Timer 3. Connect Valve Wires to Timer 4. Connect Electrical Power 5. Activate Battery A B C D E F ENGLISH 6 7 1. Select a Location When choosing a location for your timer, consider the following: • Choose location near a power source (if hard wiring) or electrical outlet (applicable only to U.S. retail timers) • Ensure operating temperatures are not below 32° or above 158° Fahrenheit (below 0° Celsius or above 70° Celsius) • Place it away from direct sunlight if possible • Ensure at least 9” of space to the left of the sprinkler timer box for the door to swing open after installation • Locate the timer where there is easy access to sprinkler wire (from valves). If mounted in an outdoor location, shut the compartment door to keep the timer safe from weather damage. To lock: insert the key and turn clockwise to the locked position Note: Sprinkler timers are weather-resistant to UL-50 and ETL® Listings, but should not be placed in areas where continuous water could cause damage. 2. Mount the Timer • Use the mounting template (included) to mark the mounting screw location on the wall. See figure 1 • Install a No. 8 screw (included) into wall in the upper template location. Leave the screw head protruding 1/8” (3mm) from wall. Use expanding anchors (included) in plaster or masonry, if necessary, for a secure hold • Slip the timer over protruding screw (using keyhole slot in back of timer). See figure 2 • Drive a No. 8 screw through one of the two pre-formed holes located in lower back cabinet. See figure 2 3. Connect Valve Wires to Timer • Strip 1/2” (12 mm) of the plastic insulation off the end of each wire for both the timer wires and the valve wires • Connect one wire from each valve (it doesn’t matter which wire) to a single “Common” sprinkler wire (usually white) • Connect the remaining wire from each valve to a separate colored sprinkler wire See figure 3 Note: The maximum loading for each station/pump is 250mA, the maximum loading for the timer is 500mA. If the distance between the sprinkler timer and valves is under 700’ (210 m), use Orbit® sprinkler wire or 20 gauge (AWG) plastic jacketed thermostat wire to connect the sprinkler timer to the valves. If the distance is over 700’ (210 m), use 16 gauge (AWG) wire. Important: All wires should be joined together using wire nuts, solder, and/or vinyl tape. In wet environments like a valve box it is recommended to use Orbit Grease Caps to prevent corrosion of the connection and for protection from water infiltration. Wiring Electric Valves Strip 1/2” (12 mm) of plastic insulation off the end of each individual wire. Each valve has two wires. One wire (it doesn’t matter which one) is to be connected as the common. The Figure 2: Hang timer on screw using keyhole Keyhole Pre-formed mounting holes No. 8 Screw Wall 1/8" Figure 1: Use Mounting Template (included) Station 1 Push tab upward to release wire Strip wire Push in Only connect one valve to each terminal (station) Figure 4 To Timer Wire Nut Solenoid Common Wire Valve Figure 3: Wiring Electric Valves other valve wire is to be connected to the specific station wire that will control that valve. The common wires for all the valves can be connected together to one common wire going to the controller. To avoid electrical hazards, only one valve should be connected to each station. See figure 4 Important: The wire can be buried in the ground; however, for more protection wires can be pulled through PVC pipe and buried under- ground. Be careful to avoid burying the wires in locations where they could bedamaged by digging or trenching in the future. Your timer is equipped with the simple “push-in” terminals for easy connection. Connect common wire to the common terminal. Connect remaining wires to corresponding terminal locations. ENGLISH