ORiNG IES-3162GC Series Manuals

4 pdf manual(s) ORiNG IES-3162GC Series for free download (Document Types: Quick installation manual, Operation & user’s manual)

ORiNG IES-3162GC Series Quick installation manual [PDF] (2 pages)

  • Identifier: id-2329110
  • Brand: ORiNG
  • Device: IES-3162GC Series Switch
  • Type: PDF
  • Key Aspects: Performance Optimization Tips, Periodic Inspection Checklists, Control Panel and Interface Navigation
  • UPD Date: 19.06.2026
  • Source File: 1958495.pdf
  • Pages: 2
  • Description: Official user manual for the ORiNG IES-3162GC Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
IES-3162GC 10/100M P7 P5 P3 P1 P8 P6 P4 P2 P15 P13 P11 P9 P16 P14 P12 P10 G2 G2 LNK/ACT Gigabit Combo G1 G2 LNK/ACT PWR PWR1 PWR2 Quick Installation Guide Quick Installation Guide Introduction PRINTED ON RECYCLED PAPER IES-3162GC is managed Redundant Ring Ethernet switch with 16x10/100Base-T(X) ports and 2xgigabit combo ports. With completely support of Ethernet Redundancy protocol, O-Ring (recovery time < 10/30ms over 250 units of connection), O-Chain, MRP *NOTE and MSTP/RSTP/STP (IEEE 802.1s/w/D) can protect your mission-critical applications from network interruptions or temporary malfunctions with its fast recovery technology. O-Chain is the revolutionary network redundancy technology that provides the add-on network redundancy topology for any backbone network, O-Chain allows multiple redundant network rings of different redundancy protocols to join and function together as a larger and more robust compound network topology. O-Chain providing ease-of-use while maximizing fault-recovery swiftness, flexibility, compatibility, and cost-effectiveness in one set of network redundancy topology. All function of IES- 3162GC can be managed centralized and convenient by a powerful windows utility — Open-Vision. In addition, the wide operating temperature range from -40 to 75 C can o satisfy most of operating environment. Therefore, the switch is one of the most reliable choice for highly-managed and Fiber Ethernet application. Preparation Before you begin installing the switch, make sure you have all of the package contents available and a PC with Microsoft Internet Explorer 6.0 or later, for using web-based system management tools. Elevated Operating Ambient: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. Reduced Air Flow: Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Safety & Warnings Dimension Panel Layouts 1. Power LED 2. PWR1 LED 3. PWR2 LED 4. R.M. status LED 5. Ring status LED 6. Faulty relay indicator 7. Console port 8. Link/Act LED for Ethernet port 9. Full/Half-duplex indicator 10. LAN ports 11. Link/Act LED for SFP ports 12. Combo ports 13. Reset button 14. Link/Act LED for Gigabit port 15. 100Mbps indicator for Gigabit port Package Contents Contents DIN-rail Kit CD IES-3162GC Pictures Number X 1 X 1 X 1 Front View Top Panel The device is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance. QIG Console Cable X 2 X 1 X 1 Wall-mount Kit 7 1 2 3 4 5 6 Rear View 1 2 1 1. Wall-mount screw holes 2. Din-rail screw holes 2 1. Terminal blocks: PWR1, PWR2 (12 48V DC), Relay - 2. Ground wire. 1 Installation Step 1: Slant the switch and screw the Din-rail kit onto the back of the switch, right in the middle of the back panel. Step 2: Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch clicks into the rail firmly. DIN-rail Installation Step 1: Screw the two pieces of wall-mount kits onto both ends of the rear panel of the switch. A total of six screws are required, as shown below. Step 2: Use the switch, with wall mount plates attached, as a guide to mark the correct locations of the four screws. Step 3: Insert a screw head through the large parts of the keyhole-shaped apertures, and then slide the switch downwards. Tighten the screws for added stability. Wall-mounting Q I G IES-3162GC 1907-200-E3162GCXX2-FX011 Mechanical Loading: Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Network Connection The switch provides standard Ethernet ports. According to the link type, the switch uses CAT 3,4,5,5e UTP cables to connect to any other network devices (PCs, servers, switches, routers, or hubs). Please refer to the following table for cable specifications. Cable Types and Specifications: Cable Type Max. Length Connector 10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45 100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45 1000BASE-T Cat. 5 / Cat. 5e 100-ohm UTP UTP 100 m (328 ft) RJ-45 10 8 9 IES-3162GC Version 2.1 154.0 96.4 13 12 PWR-1 PWR-2 1A@24V DC 50-57V V2- V2+ V1- V1+ Fault Unit =mm (Tolerance ±0.5mm) 108.5 88.0 48.3 17.5 94.0 124.0 48.0 58.0 7.50 Ø5.00 Ø8.00 80.50 62.0 87.9 40.0 15.5 14.5 49.67 Ø4.00 Ø4.00 Industrial Managed Ethernet Switch SWITCH I N D U S T R I A L *NOTE : This function is available by request only. IES-3162GC 10/100M P7 P5 P3 P1 P8 P6 P4 P2 P15 P13 P11 P9 P16 P14 P12 P10 G2 G2 LNK/ACT Gigabit Combo G1 G2 LNK/ACT PWR PWR1 PWR2 11 13 The product is open type, intended to be installed in and industrial control panel or an enclosure. 14 15 ! Warning [AVERTISSEMENT] Take into consideration the following guidelines before wiring the device [Tenez compte des directrices suivantes avant de câbler l’appareil.] 1. Terminal block is mating with Plug and suitable for 12-24AWG. Torque value 4.5 lb-in. [Le bornier est compatible avec les connecteurs et convient pour 12-24AWG. Valeur de couple 4,5 lb-in.] 2. The temperature rating of the input connection cable should higher than 105°C [La température de service nominale du câble d’entrée doit être supérieure à 105 °C] * Indoor use and pollution degree II, it must be wiped with a dry cloth for clean up the device and label. * Utilisation en intérieur et degré de pollution II, il faut l'essuyer avec un chiffon sec pour nettoyer l'appareil et son étiquette. * Do not block air ventilation holes. * Ne bouchez pas les orifices de ventilation. * If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.” * Si l’appareil est utilise d’une maniere non specifiee par le fabricant, la protection qu’il apporte peut se voir diminuee.” * Shall be mounted in the Industrial Control Panel and ambient temperature is not exceed 75 degree C * doit être monté dans le panneau de commande industriel et la température ambiante ne doit pas dépasser 75 degrés C IES-3162GC 10/100M P7 P5 P3 P1 P8 P6 P4 P2 P15 P13 P11 P9 P16 P14 P12 P10 G2 G2 LNK/ACT Gigabit Combo G1 G2 LNK/ACT PWR PWR1 PWR2

ORiNG IES-3162GC Series Operation & user’s manual [PDF] (109 pages)

  • Identifier: id-2122492
  • Brand: ORiNG
  • Device: IES-3162GC Series Ethernet switches
  • Type: PDF
  • Key Aspects: User Training Recommendations, Performance Optimization Tips, Recommended Spare Parts List
  • UPD Date: 24.06.2026
  • Source File: 2165145.pdf
  • Pages: 109
  • Description: Comprehensive user handbook for the ORiNG IES-3162GC Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
IIEESS--33116622G GCC SSeerriieess IInndduussttrriiaall M Maannaaggeedd EEtthheerrnneett SSw wiittcchheess UUsseerr M Maannuuaall VVeerrssiioonn 44..00 JJaannuuaarryy,, 22001144 wwwwww..oorriinngg--nneettwwoorrkkiinngg..ccoom m

ORiNG IES-3162GC Series Operation & user’s manual [PDF] (104 pages)

  • Identifier: id-814164
  • Brand: ORiNG
  • Device: IES-3162GC Series Network Router
  • Type: PDF
  • Key Aspects: Operational Mode Explanations, Information on Regular Maintenance, Performance Optimization Tips
  • UPD Date: 25.07.2026
  • Source File: 825600.pdf
  • Pages: 104
  • Description: User and installation guide for the ORiNG IES-3162GC Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Industrial Management Ethernet Switch IES-3162GC User’s Manual Version 1.4 Aug, 2015. ORing Industrial Networking Corp. 3F., NO.542-2, Zhongzheng Road, Xindian District, New Taipei City, 231 Taiwan Tel: + 886 2 2218 1066 Fax: + 886 2 2218 1014 Website: www.oring-networking.com E-mail: [email protected] Manufacturer’s Documents Title: Drawing No.: Rev. Level: Date: IES-3162GC user manual IES-3162GC user’s manual V1.4 2015.08.14 IES-A3162GC user manual IES-A3162GC user’s manual V1.4 2015.08.14

ORiNG IES-3162GC Series Operation & user’s manual [PDF] (111 pages)

  • Identifier: id-1052159
  • Brand: ORiNG
  • Device: IES-3162GC Series Network Router
  • Type: PDF
  • Key Aspects: Control Panel and Interface Navigation, Efficiency and Calibration Tips, Error Code Explanations
  • UPD Date: 04.04.2026
  • Source File: 1106268.pdf
  • Pages: 111
  • Description: Product instruction manual for the ORiNG IES-3162GC Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
IIG GSS--33003322G GCC IInndduussttrriiaall M Maannaaggeedd EEtthheerrnneett SSw wiittcchh UUsseerr M Maannuuaall VVeerrssiioonn 55..00 M Maarrcchh,, 22001155 wwwwww..oorriinngg--nneettwwoorrkkiinngg..ccoom m

ORiNG IES-3162GC Series: Ethernet switches, Network Router, Switch Category Related Instructions

XPRS Optimum
Satel XPRS Optimum
11.08.2026 4 pages

SATEL XPRS Optimum IP radio router • SATEL XPRS Optimum with encryption (YF0410) • SATEL XPRS Optimum without encryption (YF0415) Technical specification Subject Value Frequency range 360 … 445 MHz Tuning range 45 MHz (360 – 405 / 400 – 445) Channel Operating instructions for the Satel XPRS Optimum Network Router. The manual covers procedures for security instructions, setup instructions, setup validation, technical troubleshooting.

FlexNetwork MSR954
HPE FlexNetwork MSR954
15.08.2026 5 pages

The installation tools are not provided with the router. Prepare them yourself. Installation tools Wall-mounting the router ! ! Part number:5998-8749 HPE FlexNetwork MSR954 Routers Quick Start-6W103 4G antenna Wall anchor kit (user supplied) WLAN antenna Grou Comprehensive setup guide for the HPE FlexNetwork MSR954 Network Router. This manual explains safety information, performance optimization, network configuration.

B593
Huawei B593
08.05.2026 3 pages

Thank You for Purchasing the LTE CPE! Generally, the LTE(Long Term Evolution) CPE(customer premises equipment) will be replaced by the CPE in this guide. Before You Begin Check the following items in the product package: Item Quantity LTE CPE 1 Power adapter 1 Operating and setup manual for the Huawei B593 Network Router. The manual guides users through power management, power requirements, functional overview.

TE100-P11
TRENDnet TE100-P11
06.08.2026 2 pages

The 2-Port USB/Parallel Print Server turns most standalone USB and Parallel printers into shared resources on your network. Increase office efficiency by sharing older Parallel port printers and newer USB port printers with everyone on the Local Area Network ( Device setup guide for the TRENDnet TE100-P11 Other. It provides technical information on calibration steps, device reset instructions, error codes.