Ortus Magnet-R Manuals

1 pdf manual(s) Ortus Magnet-R for free download (Document Types: Operation manual)

Ortus Magnet-R Operation manual Main Page Preview

Operation manual [PDF] (7 pages)

  • Updated: 04.06.2026

Document Preview & Text Transcription

Attention! Reliability and life of the product are provided not only by the quality of product itself, but also by the compliance with operating modes and conditions, therefore, this document requirements is mandatory Magnetic Contact Detector Magnet-R Operation manual ORTUS Group Product Compatibility Table Compatible radio receiver Lun-R Version Configuration Software Configurator 11 Version Central Monitoring Station Orlan Version Magnet-R Version en_2 1 Contents 1. Purpose.............................................................................................................................................................................3 2. Safety Precautions.........................................................................................................................................................3 3. Technical specifications...............................................................................................................................................3 4. How to use.......................................................................................................................................................................4 4.1. Modes Indication..................................................................................................................................................5 4.2. Binding.....................................................................................................................................................................5 4.3. Wireless signal strength.....................................................................................................................................5 4.4. Installing.................................................................................................................................................................6 5. Maintenance....................................................................................................................................................................6 6. Operating conditions....................................................................................................................................................6 7. Storage..............................................................................................................................................................................6 8. Transportation................................................................................................................................................................6 9. Disposal............................................................................................................................................................................6 Magnet-R Version en_2 2 1. Purpose The Magnet-R detector (hereinafter referred to as the “detector”) is designed to detect the opening/shifting of protected objects and transmit this events to the Lun-R receiver that is con- nected to the Lun control panel (more about for compatibility, see the documentation of the rele- vant control panel). Product is not equipped with built-in cameras and microphones, devices and units for hidden video and audio recording. 2. Safety Precautions Only the employees, familiar with the module design, instructed on the safety arrangements shall be allowed to install, routinely maintain and repair. The device does not have open live parts, representing the danger of electric shock to a per- son. No safety ground. 3. Technical specifications The detector technical characteristics is shown in the Table 1. Table 1. Technical characteristics Characteristic Value Operating frequency range (depends of modification), MHz 433.05…434.79 or 868.70…869.20 Power radiated by the transmitter, mW up to 10 The health test signals period, seconds 60 Distance between detector and magnet for opening, mm More then 20 Distance between detector and magnet for close, mm Less then 5 Power source type CR123A battery Battery voltage, V 2.2…3.2 The battery predicted service life, years up to 10 Degree of protection provided by enclosure IP30 Dimensions, mm 97*25*21 Weight, g 50 Magnet-R Version en_2 3 4. How to use The detector’s PCB and battery holder are placed in a plastic enclosure with a removable cover (Figure 1). A magnetically controlled switch (reed switch), a tamper switch, a multi-color LED indicator and RESET contacts to initiate the process of binding with the Lun-R radio are placed on the detec- tor’s PCB. Figure 1. Detector, its cover and magnet Depending on external actions, the detector transmits the following events to the Lun-R re- ceiver: ● If the magnet is located near the detector housing, in the area marked by risks, then the reed switch is closed and the norm event of the detector is generated; ● If the magnet is moved away from the housing or moved away from the marked position, the reed switch opens and detector generates an alarm event; ● If the housing cover is opened, the tamper will be triggered and the tamper alarm event will be generated; ● If the voltage of the battery drops to 2.2V or lower – the event "Battery low" is generated. In addition, the detector transmits periodic test signals to the receiver to confirm its operabil- ity. When the test signals stop, the control panel generates the detector communication lost event. When the communication loss with the receiver, the detector continues to search it. Therefore, when you turn off the receiver or control panel for a long time, it is recommended to remove the detector’s battery. Magnet-R Version en_2 4