Oxford SL1640 Manuals

1 pdf manual(s) Oxford SL1640 for free download (Document Types: User instruction manual)

Document Preview & Text Transcription

User Instruction Manual Oxford ® Access Padded Sling (without Head Support) To avoid injury, read user manual prior to use. Manuel de l’utilisateur Oxford ® Sangle Access (sans support de tête) Afin d’éviter tout accident, veuillez lire attentivement la notice avant utilisation. Manual de Instrucciones Oxford ® Eslinga Arnés Access (sin soporte para la cabeza) Para evitar posibles daños, lea previamente el manual de usuario. Benutzerhandbuch Oxford ® Access Gurt (ohne Kopfstütze) Schlinge Um Verletzungen zu vermeiden, lesen Sie bitte die Gebrauchsanweisung vor der ersten Benutzung. Oxford ® Access Padded Sling (without Head Support) English 2 Introduction The Oxford® Access Padded sling has been designed specifically to facilitate the toileting process by allowing excellent access to clothing. It is an easy to fit sling, fully padded for additional comfort and provides access to allow the removal of clothing. It is not a general purpose sling and will only suit around 25% of clients. Special Sling Orders On occasions, material, dimensional and other changes outside of the standard specification are requested. Please be advised, that aside of any model specific references, fitting, washing and safety guidelines remain applicable. If you are in any doubt, please contact your authorised Oxford service agent or Joerns Healthcare directly. Statement of Intended Use A sling is an item of moving and handling equipment that is used with a mechanical lift in order to facilitate the transfer of a patient. It comprises a specially designed and constructed piece of fabric that is placed under and/or around a patient before being attached to the spreader bar/cradle of a lift to raise, transfer and lower the patient. When selected and used correctly, a sling and lift combination will achieve a safer transfer and reduce the risks associated with manual handling. It is the responsibility of a competent person to conduct a thorough risk assessment prior to using any sling, to ensure that the sling choice, method of positioning in the sling and procedure for transfer has been correctly determined for the patient. For further guidance, please contact your authorised Oxford Service Provider or Joerns Healthcare. FOR USE WITH PASSIVE LIFTS ONLY. Expected Service Life The expected service life of an Oxford sling will vary dependent on use and following the care and washing instructions provided in the user guide. Factors such as wash temperature, detergents, frequency of use and patient weight will impact on the lifetime of your sling. Joerns Healthcare recommend that slings are checked each and every time prior to use to ensure the safety of the patient. Bleached, torn, cut, frayed or broken slings are unsafe and must be discarded and replaced. It is a requirement under LOLER (Lifting Operations and Lifting Equipment Regulations 1998) that slings are thoroughly checked and passed fit for use. For further advice, please contact your authorised Oxford Service Provider or Joerns Healthcare. WARNING • OXFORD RECOMMENDS THE USE OF GENUINE OXFORD PARTS. Oxford sling and lift products are designed to be compatible with one another. For country specific guidance on sling use and compatibility, please refer to the sling label or contact your local market distributor or Joerns Healthcare. • For the safety of the patient and carer; before using a sling a full risk assessment must be conducted to ensure that the correct sling choice, method of positioning in the sling and procedure for transfer has been determined for the patient. • CHECK sling and stitching before each use. Using bleached, torn, cut, frayed or broken slings is unsafe and could result in serious injury or death to the patient. • DO NOT alter slings. Destroy and discard worn slings. • NEVER leave a patient unattended. • DO NOT exceed the rated capacity of the sling or lift. • DO NOT attempt to re-position a patient by pulling on the sling loops. Oxford ® Access Padded Sling (without Head Support) English 3 Place the sling down the back of the client and posi- tion just beneath the shoulder blades and above the belt line. Attach the buckle strap around the front of the client. There is no need for the buckle strap to be tight. The buckle strap is a positioning mechanism and not a restraint. NOTE: Padding behind the buckle straps does not need to overlap. Fitting the Sling from a Seated Position 2 1 Raise the client’s leg and feed the leg strap under and up between the legs. Ensure that the sling fabric is not twisted or creased under the thigh. Repeat this procedure for the other leg. Oxford ® Access Padded Sling (without Head Support) English 4 Raise the hoist to the required height. When reseating the client, apply light pressure on the client’s thigh(s) to ensure good posture is maintained. NOTE: This sling is not recommended for use from a lying position. 3 4 Cross over the leg straps and attach to the spreader bar on the front hooks using the longest loop. Raise the hoist and attach your desired shoulder loop to the rear hooks (a more upright position will be achieved using the shortest loop). NOTE: The hoist may move towards the client. NOTE: Some adjustment of the shoulder and/or leg loop attachment points may be needed to better suit the client’s height or body shape. Shoulder/leg loop attachment points should be connected at a similar length in order to achieve a balanced lift.