Document Preview & Text Transcription
Operating Instructions
Remote Control Unit
Model No. AJ-
P
VQT0M57
Printed in Japan
F0604W0 @
P
Before operating this product, please read the instructions carefully and save this manual for future use.
2
indicates safety information.
$ THIS APPARATUS MUST BE GROUNDED
To ensure safe operation the three-pin plug must be
inserted only into a standard three-pin power outlet which
is effectively grounded through normal household wiring.
Extension cords used with the equipment must be three-
core and be correctly wired to provide connection to the
ground. Incorrectly wired extension cords can be
extremely hazardous.
The fact that the equipment operates satisfactorily does
not imply that it is grounded, and the installation is not
necessarily safe. For your safety, if in any doubt about
the effective grounding of the equipment or power outlet,
please consult a qualified electrician.
CAUTION:
TO REDUCE THE RISK OF FIRE OR SHOCK
HAZARD AND ANNOYING INTERFERENCE, USE
THE RECOMMENDED ACCESSORIES ONLY.
CAUTION:
Do not install or place this unit in a bookcase,
built-in cabinet or any other confined space in
order to maintain adequate ventilation. Ensure
that curtains and any other materials do not
obstruct the ventilation to prevent risk of electric
shock or fire hazard due to overheating.
CAUTION:
TO REDUCE THE RISK OF FIRE OR SHOCK
HAZARD, REFER CHANGE OF SWITCH SETTING
INSIDE THE UNIT TO QUALIFIED SERVICE
PERSONNEL.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol,
within an equilateral triangle, is intended to alert
the user to the presence of uninsulated
“dangerous voltage” within the product’s
enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
The exclamation point within an equilateral
triangle is intended to alert the user to the
presence
of
important
operating
and
maintenance (service) instructions in the
literature accompanying the appliance.
CAUTION:
This apparatus can be operated at a voltage in the
range of 100 – 240 V AC.
Voltage other than 120 V is not intended for U.S.A.
and Canada.
CAUTION:
Operation at a voltage other than 120 V AC may
require the use of a different AC plug. Please contact
either a local or foreign Panasonic authorized service
center for assistance in selecting an alternate AC
plug.
WARNING:
OTO REDUCE THE RISK OF FIRE OR SHOCK
HAZARD, DO NOT EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE.
OTO REDUCE THE RISK OF FIRE OR SHOCK
HAZARD, KEEP THIS EQUIPMENT AWAY FROM
ALL LIQUIDS-USE AND STORE ONLY IN
LOCATIONS WHICH ARE NOT EXPOSED TO
THE RISK OF DRIPPING OR SPLASHING
LIQUIDS, AND DO NOT PLACE ANY LIQUID
CONTAINERS ON TOP OF THE EQUIPMENT.
CAUTION:
THE AC OUTLET (MAINS SOCKET) SHALL BE
INSTALLED NEAR THE EQUIPMENT AND SHALL
BE EASILY ACCESSIBLE.
CAUTION:
Even when the Power Switch is in the OFF
position, a small current flows the filter circuit.
FCC Note:
This equipment has been tested and found to comply
with the limits for a class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful
interference when the equipment is operated in a
commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful interference to
radio communications.
Operation of this equipment in a residential area is
likely to cause harmful interference in which case the
user will be required to correct the interference at his
own expense.
Warning:
To assure continued FCC emission limit compliance,
the user must use only shielded interface cables when
connecting to external units. Also any unauthorized
changes or modifications to this equipment could void
the user’s authority to operate it.
Operating precaution
Operation near any appliance which generates strong magnetic fields may give rise to noise in the video and audio signals. If this
should be the case, deal with the situation by, for instance, moving the source of the magnetic fields away from the unit before
operation.
3
Thank you for purchasing the AJ-RC905 remote control unit (which will be referred to as “the unit” in these
instructions).
Connecting the unit to a camera recorder and camera adapter (AJ-CA905G) using a 26-pin multi-cable makes
it possible to operate the camera recorder as a system camera and broaden the range of the applications and
uses of the camera recorder.
Camera recorders which support the unit:
AJ-SDC615, AJ-SDC905
To ascertain whether any other camera recorders are compatible with the unit, consult your dealer.
Contents
Checking the accessories provided with the unit
Checking the accessories provided
with the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Precautions for system connections . . . . . . . . . . .4
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Parts and their functions . . . . . . . . . . . . . . . . . . . .5
Front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Rear panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Setting the internal switches . . . . . . . . . . . . . . . .11
Connector pin signals . . . . . . . . . . . . . . . . . . . . . .12
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Power cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Tally connector . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Precautions for system connections
Bear in mind the following points when
connecting the camera recorder and unit as a
system.
$ Do not input signals to the GENLOCK IN connector
of the camera recorder.
$ Do not connect both the unit and an ECU
(extension control unit: AJ-EC3P) to the camera
recorder at the same time.
$ Some of the camera recorder’s selector switches
(including GAIN, CAM BAR SW, WHITE BAL and
SHUTTER) will have no effect.
$ Any functions not listed below, if allocated to the
camera recorder’s USER buttons (USER MAIN,
USER1 and USER2), will have no effect.
OINH
OAUDIO CH1
OAUDIO CH2
OREC SW
ORET SW
$ All settings established for items on the USER SW
GAIN screen on the OPERATION page will have no
effect.
$ Even when OFF settings are selected for the
SHUTTER SPEED items of the camera recorder,
they will all be changed to ON settings.
$ When inputting the return signal to the unit and
monitoring it on the viewfinder of the camera
recorder, the viewfinder image may be disrupted at
the moment when the RET button on the lens is
pressed.
$ When the OUTPUT SEL switch on the camera
recorder is set to the OFF position, no signals will
be output from the MON OUT connector.
$ The microphone which is used for INCOM (Inter-
Communication) is set to the “carbon type” (at the
factory). Switching to the “dynamic type” requires a
change in the position of one of the unit’s internal
switches.
For details, consult your dealer.
$ The gain value will be set to low even when the
GAIN selector switch on the camera recorder is at
the “M” or “H” position.
It will also be set to low after the power of the
camera recorder is switched from OFF to ON.
$ When the camera recorder is detached from the
unit, the settings of the camera recorder will be
restored as the unit’s GAIN switch, WHITE BAL
switch and SHUTTER switch settings.
$ Before performing the system adjustments for all
the devices connected, turn on the power of the
camera recorder.
$ If, while a menu is displayed, the unit’s
START/STOP button or VTR START/STOP button
on the camera recorder is pressed, the unit’s SET
UP lamp will light, but the menu display will be
cleared from the screen.
To display the menu again, set the SET UP button
from OFF to ON.
$ MAIN MENU contains the menu items which can be
operated using this unit. The menu items on other
menus such as USER MENU and OPTION MENU
are not displayed.
$ Normal composite signals are output from the unit’s
MONITOR connector.
The viewfinder images cannot be checked at the
MONITOR connector.
Check the following menu settings on the
viewfinder of the camera recorder.
SYSTEM SETTING page
OUTPUT SEL screen
O VF MODE item
PAINT page
SKIN TONE DTL screen (all items)
VF page
VF DISPLAY screen
O ZEBRA1 DETECT item
O ZEBRA2 DETECT item
O ZEBRA2 item
VF MARKER screen (all items)
USER BOX screen (all items)
!LED screen (all items)
$ The devices connected to configure a system are
synchronized with the reference signal connected
to the unit regardless of the setting selected for the
GENLOCK item of the camera recorder.
$ Execute black shading compensation by performing
the operations for the menu items below.
MAINTENANCE page
BLACK SHADING screen
O DETECTION (DIG) item
The black shading cannot be compensated by
pressing the ABB button on the unit or ABB button
on the camera recorder.
4