Paradox VDMP3 Manuals
1 pdf manual(s) Paradox VDMP3 for free download (Document Types: Operation & user’s manual)
Paradox VDMP3 Operation & user’s manual [PDF] (2 pages)
- Identifier: id-807166
- Brand: Paradox
- Device: Paradox VDMP3 Control Unit
- Type: Operation & user’s manual, PDF
- Key Aspects: Common Issue Diagnostic Flows, Error Code Explanations, Regulatory Compliance and Standards
- UPD Date: 11.05.2026
- Source File: 832958.pdf
- Pages: 2
- Description: Manual for installation and usage of the Paradox VDMP3.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
2. When the VDMP3 answers the line, you are prompted to enter your usual access code. “Please enter your access code.” 3. Each area’s status is given. “Area 1 armed, Area 2 disarmed...” 4. Options are given to arm/disarm and control PGM features. “Press 1 to arm or disarm the system. Press 2 to control features.” NOTE: If you hang up while in communication with the VDMP3, you must wait 2 minutes before connecting again. To avoid having to wait, press “#” to disconnect from the VDMP3 before hanging up. Receiving a Call From the VDMP3 (alarm in system) When the VDMP3 calls because of an alarm in the system, the VDMP3 plays the Voice ID (if recorded), informs you of the alarm, and gives options to control the system. “Alarm in Mary’s house. Area 2 in alarm. Zone 3. Press 1 to disarm the system. Press pound twice (##) to hang up.” • To acknowledge the alarm, press “##”. Alarm reporting stops. • To acknowledge and disarm the system, press 1 + [ACCESS CODE]. • To have the VDMP3 call the next telephone number, simply hang up. Special Telephone Keys Use special telephone keys when programming telephone numbers in Step 3 of the Programming section. Feature Activation (PGMs) By activating or deactivating the VDMP3’s 8 Features, it is possible to activate the PGM utility keys or PGMs that are programmed in the control panel. For example, when activating VDMP3 Features, the following message is played: “Press 1 to activate / deactivate Feature 1” “Press 2 to activate / deactivate Feature 2” ... “Press star ( ) to exit” “Press star (#) to hang up” Magellan / Spectra SP VDMP3 features can activate the first 8 PGMs as programmed in the control panel. EVO VDMP3 feature numbers correspond to EVO utility keys according to the following table: NOTE: If a utility key in the EVO control panel is programmed with a timer, the VDMP3 will not recognize PGM deactivation when the set timer elapses. As a result, the VDMP3 may indicate that the PGM is ON when actually the timer has elapsed and the PGM is in fact OFF. VDMP3 Plug-In Voice Module V1.2 Installation The VDMP3 is installed directly onto the control panel’s DIALER and EBUS connectors as shown. Function Key Function Key [STAY] Clear [CLEAR] # [FORCE] Delete [TRBL] Switch Tone / Pulse Dialing (T) [ARM] Delete from cursor to the end [ACC] Wait for second dial tone (W) [DISARM] Insert space [MEM] 4-second pause (P) [BYP] Dial 9 for outside line 9+[STAY] VDMP3 Feature EVO Utility Key VDMP3 Feature EVO Utility Key Feature 1 ON Utility Key 1 Feature 5 ON Utility Key 9 Feature 1 OFF Utility Key 2 Feature 5 OFF Utility Key 10 Feature 2 ON Utility Key 3 Feature 6 ON Utility Key 11 Feature 2 OFF Utility Key 4 Feature 6 OFF Utility Key 12 Feature 3 ON Utility Key 5 Feature 7 ON Utility Key 13 Feature 3 OFF Utility Key 6 Feature 7 OFF Utility Key 14 Feature 4 ON Utility Key 7 Feature 8 ON Utility Key 15 Feature 4 OFF Utility Key 8 Feature 8 OFF Utility Key 16 * * Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending patents may apply. Canadian and international patents may also apply. Trademarks: Digiplex EVO, Magellan and Spectra SP are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries. Certification: For the latest information on products approvals, such as UL and CE, please visit www.paradox.com. Warranty: For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all warranty terms and conditions. © 2009 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. VDMP3-EI06 12/2009 PARADOX.COM Printed in Canada Description The VDMP3 provides a voice-assisted link with the control panel and can be programmed to call one or more telephone numbers in the event of an alarm. You can also call the VDMP3 from an outside line, enabling you to arm or disarm the system as well as activate PGMs. The VDMP3 essentially turns any outside telephone into a keypad. Features • Compatible with Spectra SP (V2.10 or higher), MG Series (V2.10 or higher), EVO control panels and PCS200 GPRS/GSM module • Record a "Voice ID" to identify the installation site • Dial up to 8 telephone numbers to report a burglar, panic or fire alarm using prerecorded messages • Arm/disarm the system remotely via telephone • Control PGMs and toggle utility keys remotely via telephone • Voice-guided menu • In-field upgradable • Connects directly onto the control panel 1 Overview 1. Mounting pin hole 2. Feedback LEDs 3. Expansion port 2 Specifications Compatibility EVO48 EVO192 EVO96 V1.5 or higher MG Series V2.10 or higher Spectra SP Series V2.10 or higher Power Consumption 35mA Audio 18,345Hz Dimensions 2.5 x 2.5 in. (6.4 x 6.4 cm) 3 3 2 4 5 To Install the VDMP3: 1. Power down the control panel. 2. Attach support pin to EVO panel and VDMP3. 3. For serial / RS485 conversion, connect the CVT485 to the expansion port. 4. Connect VDMP3 to DIALER and EBUS. 5. Connect 306USB / 307USB or CONV3USB / CV4USB (WinLoad / NEware) to SERIAL. 6. Power up the control panel after the VDMP3 has been successfully connected.
Similar Manuals in the Control Unit Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
YASKAWA MP2000 Series |
MP2000 Series Operation & user’s manual - 9R55O1 |
56 | 1286 | 271 | 22-05-2026 | view all manuals | |
Bailey INFI 90 IMCOM03 |
PDF Manual (@N9KE1B), Bailey INFI 90 IMCOM03 Control Unit (07-06-2026) |
77 | 340 | 75 | 07-06-2026 | view all manuals | |
Exodraft EBC24 Series |
Control Unit #RDE5KC |
28 | 921 | 166 | 19-04-2026 | view all manuals | |
Juniper T320 |
Network Router #J8N37E |
32 | 1296 | 286 | 29-04-2026 | view all manuals | |
STIEBEL ELTRON SBP 200 E |
SBP 200 E (Control Unit ePDF Guide, #33GPJ8) |
60 | 721 | 159 | 02-05-2026 | view all manuals | |
Dräger Evita V Series |
PDF User Manual (@WXC2IM), Dräger Evita V Series Control Unit (11-04-2026) |
3 | 897 | 135 | 11-04-2026 | view all manuals |