Parker Balston FID 1000 Manuals

1 pdf manual(s) Parker Balston FID 1000 for free download (Document Types: Installation, operation and maintenance manual)

Parker Balston FID 1000 Installation, operation and maintenance manual Thumbnail

Parker Balston FID 1000 Installation, operation and maintenance manual [PDF] (21 pages)

  • Identifier: id-1593420
  • Brand: Parker
  • Device: Parker Balston FID 1000 Laboratory Equipment
  • Type: Installation, operation and maintenance manual, PDF
  • Key Aspects: Performance Optimization Tips, Operational Mode Explanations, FAQ Section for Common Queries
  • UPD Date: 28.06.2026
  • Source File: 1587294.pdf
  • Pages: 21
  • Description: Complete technical documentation for the Parker Balston FID 1000.
Pages Preview:
  • Parker Balston FID 1000 Installation, operation and maintenance manual preview - page 2
  • Parker Balston FID 1000 Installation, operation and maintenance manual preview - page 3
  • Parker Balston FID 1000 Installation, operation and maintenance manual preview - page 4
  • Parker Balston FID 1000 Installation, operation and maintenance manual preview - page 5
  • Parker Balston FID 1000 Installation, operation and maintenance manual preview - page 6
  • Parker Balston FID 1000 Installation, operation and maintenance manual preview - page 7
  • Parker Balston FID 1000 Installation, operation and maintenance manual preview - page 8
  • Parker Balston FID 1000 Installation, operation and maintenance manual preview - page 9
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Bulletin TI-FID1000C FID 1000 and 2500 Gas Stations Parker Hannifin Corporation Filtration and Separation Division Haverhill, MA • 1-800-343-4048 www.parker.com/ags 1 ����������������������������� ���������������������� ����������������������������������������������� Parker Hannifin Corporation Filtration and Separation Division Haverhill, MA • 1-800-343-4048 www.parker.com/ags Bulletin TI-FID1000C Figure 1 - FID Gas Stations FID Gas Stations (see Figure 1) are completely engineered systems designed to produce ultra pure, dry hydrogen gas from deionized water using a Proton Ex- change Membrane cell. The hydrogen generator utilizes the principle of electrolytic dissociation of water and hydrogen proton conduction through the membrane. The hydrogen stream is dried using a coalescing filter,a drying tube and dessicant. The outlet pressure of the hydrogen unit is 60 psi (4.08 Barg) with a maximum hydro- gen delivery flow rate of 90 cc/min for Model 1000, and 250 cc/min for Model 2500. The FID gas stations are ideal for use as fuel gas in Flame Ionization Detectors (FID’s), Trace Hydrocarbon Analyzers, and other general laboratory equipment requiring a source of pure hydrogen. Parker Balston Gas Stations also incorporate a Zero Air Generator (ZAG) which will replace inconvenient high pressure gas cylinders as a source of hydrocarbon-free air. This will purify on site compressed air to a total hydrocarbon concentration of less than 0.1 ppm (measured as methane). The ZAG may be used to generate fuel for Flame Ionization Detectors (FID’s) or for a zero reference for any instruments which measure hydrocarbon concentration. Model 1000 is capable of producing 1000 cc/min of zero grade air and will serve up to three FID’s, and Model 2500 will serve up to six FIDs. General Description These instructions must be thoroughly read and understood before install- ing and operating this product. Any modification of the product will void the warranty. Failure to operate this product in accordance with the instructions set forth in this manual and other safety governing bodies could jeopardize the safety of the operator and void the safety certification of this product. If you have any questions or concerns, please call the Technical Services Department at 800-343-4048, 8AM to 5PM Eastern Time (North America only). For other locations, please contact your local representative. Do not use a Hydrogen gas storage vessel in conjunction with the Hydrogen generator. Stored quantities of hydrogen pose an explosion hazard. Normal precautions for any hydrogen supply should be taken when using the hydrogen generator. DO NOT USE IN A SEALED OR UNVENTED ROOM. CAUTION: DO NOT USE AN OPEN FLAME OR OTHER IGNITION SOURCE WITHIN 10 INCHES (25cm) OF THE OXYGEN VENT! ���������� ����������� ® FRONT VIEW RIGHT SIDE VIEW

Similar Manuals in the Laboratory Equipment Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Halma Ocean Insight FLAME-DA-CUV-UV-VIS

Ocean Insight FLAME-DA-CUV-UV-VIS Installation and operation instructions manual - Q716WF

8 1041 177 28-07-2026 view all manuals
Viso Systems LabRail

#RFQ7Q6: LabRail Laboratory Equipment Operation & user’s manual

25 964 145 08-03-2026 view all manuals
Mold-Masters TempMaster XL-2 Series

PDF Manual (@8918NX), Mold-Masters TempMaster XL-2 Series Laboratory Equipment (21-06-2026)

39 438 92 21-06-2026 view all manuals
Taylor c713

Taylor Laboratory Equipment Original operating instructions (File: PDF, 24-06-2026)

52 1157 255 24-06-2026 view all manuals
Renfert Bijou 90 Series

Bijou 90 Series (Burner ePDF User Guide, #XLO8A8)

62 1104 243 29-07-2026 view all manuals
Sea-Bird Scientific SBE 33

PDF Guide (@Y8OND2), Sea-Bird Scientific SBE 33 Laboratory Equipment (26-03-2026)

55 1336 214 26-03-2026 view all manuals